Product Description
The SHENTEK® REO-3 Analysis Kit is a qualitative assay serving as an analytical quality control reagent engineered exclusively for the molecular evaluation of bioprocessing inputs, such as in vitro cell culture supplements and cell banks. Optimized for compatibility with the SHENTEK® Nucleic Acid Extraction Kit (Product No. 1506730), this assay ensures the efficient recovery and analysis of target nucleic acids from complex industrial matrices.
Technical Specifications
| Parameter | Details |
|---|---|
| Intended use | Qualitative detection of Reovirus 3 (REO-3) contamination in cell banks, virus seed banks and bovine serum |
| Assay sensitivity / Limit of detection (LOD) | 50 copies per reaction |
| Specificity | No cross-amplification with bovine, porcine genomes, common production/engineering cell lines (CHO, Vero, 293T, MDCK, NS0, Sf9) or engineering bacteria (E. coli, Pichia pastoris) |
| Reaction volume | 20 μL total reaction volume (10 μL RT-qPCR MIX + 10 μL sample or control) |
| Thermal cycling conditions | Reverse transcription: 50 °C 15:00 (1 cycle); Activation: 95 °C 00:30 (1 cycle); Denaturation: 95 °C 00:15; Annealing/extension: 60 °C 01:00; 45 cycles (fluorescence read during annealing/extension) |
| Controls and interpretation thresholds | Controls: NTC, NCS, PCS, Internal Positive Control (IPC). Typical Ct acceptance criteria: FAM (target): Positive if Ct < 40.00 (at least one well) or Ct < 40 with duplicate amplification; VIC (IPC): Ct < 35.00 indicates valid IPC amplification. NTC/NCS: no specific amplification (Ct ≥ 40 or absent) required. See user guide tables for full interpretation rules. |
| Kit size / throughput | Reagents for 50 reactions |
| Storage & stability | Store components at -20 °C (recommended). Kit components stable for up to 24 months; items with recommended storage at -20 °C should be maintained within ±10 °C (–30 °C to –10 °C). |
| Compatible instruments | SHENTEK-96S, LightCycler 480 II, ABI 7500, Bio-Rad CFX96 and other real-time PCR systems supporting probe assays and user-defined cycling |
Features
- High sensitivity: Analytical sensitivity down to 50 copies per reaction (LOD).
- High specificity: No cross-amplification with common cell lines (CHO, Vero, 293T, MDCK, NS0, Sf9) or bacterial/yeast genomes (E. coli, Pichia pastoris), and with bovine/porcine genomes.
- Complete RT-qPCR solution: Includes primer & probe mix, RT-qPCR enzyme mix, buffer and internal positive control mix for end-to-end detection when combined with recommended extraction kit.
- Compatible with multiple instruments: Validated on several common real-time PCR platforms and supports standard probe-based RT-qPCR setup.
- Designed for complex matrices: Optimized to detect REO-3 RNA from cells and bovine serum when used with SHENTEK® Virus DNA & RNA Extraction Kit.
- Internal control included: IPC MIX provided to monitor extraction and PCR inhibition.
Applications
- Qualitative molecular analysis of REO-3 target sequences in industrial cell banks
- Analytical quality control of biological seed lots
- Molecular evaluation of in vitro cell culture supplements for REO-3 nucleic acids
- In-process monitoring and lot-release analysis for biological manufacturing
- In vitro research projects assessing REO-3 target sequences in complex culture matrices
Kit Contents
Attention
• For Research Use Only (RUO). Not for use in diagnostic procedures.
• Read Material Safety Data Sheets (MSDS) and wear appropriate PPE (eyewear, mask, gloves, protective clothing).
• Handle positive control and extraction in a biosafety cabinet and follow BSL-2 safety guidelines.
• Use nuclease-free consumables and certified RNase/DNase-free reagents and tips to avoid contamination.
• Thaw kit completely at 2–8 °C or on ice, vortex and centrifuge briefly before use.
• Protect primer & probe mixes from light.
• Store components at -20 °C; short-term storage below -30 °C is acceptable if supported by stability data.
• Check expiration dates on labels prior to use.
• If IPC (VIC) signal indicates inhibition, repeat sample preparation or remove inhibitors and repeat assay.
Quality Management & Certifications
Quality System
Download QMSQMS (ISO, GMP)
Download CertificateQuality Advantages
View ReportQuality Control Process
Download ProcessTechnical Resources & Downloads
Frequently Asked Questions (FAQ)
Research Use Only
For Research Use Only (RUO) – This product is intended for laboratory research purposes only and not for clinical or regulatory diagnostic use.
Not intended for use in USDA or FDA regulated diagnostic testing or official compliance testing.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.