You have no items in your shopping cart.
Description
Accurate measurement of noradrenaline (norepinephrine, NE) levels is important for understanding catecholamine regulation, sympathetic nervous system activity, and neuroendocrine responses in animal research models. Changes in norepinephrine concentration may reflect alterations in stress response pathways, autonomic regulation, cardiovascular function, and neurotransmitter metabolism. Reliable quantification of rat NE levels requires a sensitive and reproducible assay capable of analyzing complex biological samples.
The Rat Noradrenaline (Norepinephrine) ELISA Kit is designed for quantitative detection of noradrenaline levels in rat biological samples using a double antibody sandwich ELISA method. This research-use-only ELISA kit provides a convenient solution for researchers performing rat norepinephrine analysis in serum, plasma, cell culture supernatants, and tissue homogenates.
Noradrenaline, also known as norepinephrine, is a major catecholamine neurotransmitter involved in neuronal signaling, sympathetic nervous system activation, and physiological stress responses. Measuring NE concentration in rat experimental samples can support studies focused on neuroscience, stress biology, cardiovascular regulation, pharmacological evaluation, and neuroendocrine mechanisms.
The Rat Norepinephrine ELISA Kit utilizes pre-coated microplate wells, HRP-labeled detection antibodies, and TMB colorimetric detection technology. After antigen-antibody binding and enzymatic reaction, the optical density is measured at 450 nm, and sample concentrations are calculated according to the generated standard curve.
This Rat Noradrenaline ELISA Kit is intended for Research Use Only (RUO) and is not designed for clinical diagnosis, therapeutic applications, or human testing.
Specifications
| Product Name | Rat Noradrenaline (Norepinephrine) ELISA Kit |
| Alternative Name | Rat Norepinephrine ELISA Kit; Rat NE ELISA Kit; Noradrenaline (NE) ELISA Assay Kit |
| SKU | YX-140500R |
| Species | Rat |
| Target | Noradrenaline / Norepinephrine (NE) |
| Assay Type | Double Antibody Sandwich ELISA |
| Detection Method | Colorimetric ELISA Detection |
| Detection Wavelength | 450 nm |
| Sample Types | Rat Serum, Rat Plasma, Cell Culture Supernatant, Rat Tissue Homogenate |
| Standard Range | 0–8 ng/mL |
| Standard Concentrations | 0, 0.5, 1, 2, 4, 8 ng/mL |
| Sensitivity | <0.1 ng/mL |
| Sample Dilution | 5-fold dilution before calculation |
| Storage | 2–8°C, protected from light and moisture |
| Shelf Life | 6 months |
| Application | Research Use Only (RUO) |
Features
-
Rat-Specific Noradrenaline Detection: Designed for quantitative measurement of rat norepinephrine (NE) levels in experimental biological samples.
-
Double Antibody Sandwich ELISA Format: Uses antibody-based capture and HRP-labeled detection systems to provide reliable quantitative analysis of noradrenaline concentrations.
-
Sensitive Catecholamine Measurement: Provides a detection sensitivity of less than 0.1 ng/mL for studying low-abundance neurotransmitter biomarkers.
-
Multiple Biological Sample Compatibility: Suitable for rat serum, plasma, tissue homogenates, and cell culture supernatants.
-
Standard Curve-Based Quantification: Includes calibrated NE standards for calculating sample concentrations through OD450 measurement.
-
Colorimetric Microplate Detection: Compatible with standard microplate readers using 450 nm absorbance detection.
-
Research Applications in Catecholamine Biology: Supports neuroscience, stress response, cardiovascular, and pharmacological research involving noradrenaline signaling.
-
Research Use Only: For laboratory research applications only and not intended for diagnostic or therapeutic use.
Assay Principle
The Rat Noradrenaline (Norepinephrine) ELISA Kit is based on a double antibody sandwich ELISA principle. Microplate wells are pre-coated with antibodies specific to noradrenaline. When rat samples or standards are added, NE binds to the capture antibodies immobilized on the plate.
After incubation and washing, an HRP-conjugated detection antibody is added to form an antibody-antigen-antibody complex. Following additional washing steps, TMB substrate is introduced. HRP catalyzes the color reaction, and the intensity of the generated color is measured at 450 nm.
The optical density value is proportional to the concentration of noradrenaline present in the sample. Sample concentrations are determined by comparing measured OD values with the NE standard curve.
Applications
The Rat Noradrenaline ELISA Kit provides quantitative detection of norepinephrine for a variety of laboratory animal research applications involving catecholamine signaling, autonomic regulation, and physiological responses.
-
Rat Neuroscience Research: Measurement of norepinephrine levels to investigate neurotransmitter regulation, neuronal signaling pathways, and neurochemical changes in rat models.
-
Rat Stress Response Studies: Analysis of NE concentration changes associated with physiological stress, environmental stimulation, and stress-related biological responses.
-
Sympathetic Nervous System Research: Evaluation of sympathetic activation and autonomic nervous system regulation through quantitative rat norepinephrine detection.
-
Cardiovascular Research: Investigation of catecholamine-related mechanisms involved in cardiovascular regulation, adrenergic signaling, and vascular responses.
-
Neuroendocrine Studies: Research on hormone-neurotransmitter interactions and biological pathways involving catecholamine regulation.
-
Pharmacological Research: Assessment of drug-induced changes in noradrenaline metabolism and neurotransmitter-related pathways in rat models.
-
Animal Model Studies: Quantitative monitoring of norepinephrine levels in rat experimental models for physiological and biochemical research.
-
Biomarker Analysis: Supports laboratory investigation of NE as a catecholamine biomarker in biological samples.
Sample Types
The Rat Noradrenaline (Norepinephrine) ELISA Kit is compatible with commonly used rat biological samples for catecholamine research. Proper sample preparation is essential for obtaining accurate and reproducible norepinephrine measurements.
-
Rat Serum: Serum samples collected using appropriate tubes and centrifuged to separate serum from blood cells before analysis.
-
Rat Plasma: Plasma samples collected with EDTA, citrate, or heparin anticoagulants for norepinephrine quantification.
-
Rat Tissue Homogenate: Tissue samples homogenized with physiological saline and centrifuged to obtain supernatant for NE detection.
-
Cell Culture Supernatant: Cell-derived biological fluids processed by centrifugation to remove particles and suitable for ELISA analysis.
-
Other Rat Biological Samples: Additional experimental samples may be evaluated according to specific research requirements and sample preparation procedures.
Assay Workflow
The Rat Norepinephrine ELISA Kit provides a straightforward microplate-based workflow for quantitative NE analysis.
-
Bring all reagents and samples to room temperature before starting the assay. Remove the required microplate strips from the sealed package and equilibrate for approximately 20 minutes.
-
Add 50 μL of NE standards into standard wells to generate the calibration curve.
-
Add 10 μL of rat sample followed by 40 μL of sample diluent into sample wells.
-
Add 100 μL of HRP-conjugated detection antibody into each well except blank wells, then incubate at 37°C for 60 minutes.
-
Wash the plate thoroughly to remove unbound components. Proper washing is important for reducing background signal and improving assay consistency.
-
Add 50 μL substrate solution A and 50 μL substrate solution B to each well, then incubate at 37°C for 15 minutes protected from light.
-
Add 50 μL stop solution to terminate the reaction and measure absorbance at 450 nm within 15 minutes.
-
Calculate rat norepinephrine concentration using the standard curve generated from the provided NE standards.
Performance Characteristics
| Accuracy | Standard curve correlation coefficient (R) ≥ 0.9900 |
| Sensitivity | <0.1 ng/mL |
| Specificity | No significant cross-reactivity with other soluble structural analogs |
| Precision | Intra-assay and inter-assay coefficient of variation <15% |
| Storage Condition | 2–8°C, avoid light and moisture |
| Validity Period | 6 months |
FAQ
What is the Rat Noradrenaline (Norepinephrine) ELISA Kit used for?
The Rat Noradrenaline ELISA Kit is used for quantitative measurement of norepinephrine (NE) levels in rat biological samples. It supports research applications including neuroscience studies, stress response analysis, cardiovascular research, and catecholamine pathway investigations.
What samples can be tested with a Rat Norepinephrine ELISA Kit?
This Rat Norepinephrine ELISA Kit is suitable for rat serum, rat plasma, cell culture supernatants, and rat tissue homogenates. Samples should be properly prepared and processed according to the recommended protocol.
What is the detection principle of this Rat NE ELISA Kit?
The kit uses a double antibody sandwich ELISA method. Noradrenaline in samples is captured by immobilized antibodies and detected using an HRP-labeled detection antibody. The resulting TMB color reaction is measured at 450 nm to determine NE concentration.
Why measure norepinephrine levels in rat models?
Norepinephrine is an important catecholamine neurotransmitter involved in sympathetic nervous system activity and physiological stress responses. Measuring rat NE levels can help researchers evaluate changes in neurochemical regulation, autonomic function, and stress-related pathways.
What is the standard concentration range of this Rat Noradrenaline ELISA Kit?
The provided NE standards include concentrations of 0, 0.5, 1, 2, 4, and 8 ng/mL. Sample concentrations are calculated by comparing measured OD450 values with the generated standard curve.
What equipment is required for the Rat Norepinephrine ELISA assay?
The assay requires a microplate reader capable of measuring absorbance at 450 nm, precision pipettes, disposable pipette tips, and a 37°C incubator or temperature-controlled device.
Can this Rat Noradrenaline ELISA Kit be used for clinical diagnosis?
No. This product is intended for Research Use Only (RUO) and is not approved for diagnostic, therapeutic, or human testing applications.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.

