Description

Maintaining a controlled clean environment is important for laboratory workflows that require reduced airborne particle contamination during daily operations. Unstable airflow conditions, insufficient workspace cleanliness, or difficult-to-maintain working areas may affect the consistency of contamination-sensitive procedures.

The AG1000 Laminar Flow Clean Bench is a single person, single side ISO Class 5 Clean Bench designed to provide a controlled clean airflow workspace for laboratory applications. Featuring LCD digital control, adjustable airflow settings, UV sterilization scheduling, and a corrosion-resistant 304 stainless steel work surface, the AG1000 supports reliable operation in clean environment applications.

Designed as a laboratory Laminar Flow Clean Bench, the AG1000 provides uniform clean airflow coverage throughout the working area. The system incorporates a glass side wall design, real-time parameter display, filter life indication, pre-filter protection, and user-friendly maintenance features to support efficient laboratory workflows.

The AG1000 Laminar Flow Clean Bench is suitable for laboratories requiring a stable Clean Air Bench environment, including sample preparation and other applications requiring a controlled clean workspace.

Specification

Model AG1000
General Specifications Clean Bench Type Laminar Flow Clean Bench
Control Interface Push-button LCD Display
Cleanliness ISO Class 5, Class 100
Noise Level ≤62 dB
Illumination ≥300 Lux
Power Consumption 250 W
Operation Mode Single Person / Single Side
Power Supply 115V~230V ±10%, 50~60Hz
Working Area Working Area Dimensions (W×D×H) 870 × 690 × 520 mm
External Dimensions (W×D×H) 1010 × 725 × 1625 mm
Work Surface Material 304 Stainless Steel
Front Window Material 5 mm Toughened Glass
Weight 130 kg
Functions Sterilization Method UV Sterilization
Airflow Adjustment Three-step Speed Adjustment
Ambient Temperature 10~30°C
Display Parameters Wind Speed, Time, Temperature and Other Parameters

Features

  • ISO Class 5 Clean Air Workspace

    The AG1000 provides an ISO Class 5 clean working environment with uniform airflow distribution, supporting laboratory procedures requiring controlled cleanliness and sample protection.

  • Laminar Airflow Design

    The laminar airflow structure provides continuous clean airflow coverage across the working area, helping maintain a stable clean environment during laboratory operations.

  • LCD Digital Control Interface

    The LCD digital control system provides touch key operation with three-step airflow speed adjustment and real-time display of wind speed, time, temperature, and other operating parameters.

  • UV Sterilization Scheduling Function

    The built-in UV sterilization function supports one-key appointment settings, allowing users to schedule sterilization operations according to laboratory workflow requirements.

  • 304 Stainless Steel Work Surface

    The corrosion-resistant 304 stainless steel working surface provides a durable and easy-to-clean area for routine laboratory operations.

  • Adjustable Glass Window System

    The 5 mm toughened glass front window uses an adjustable suspension lifting system, allowing flexible opening and positioning at different heights within the travel range.

  • Lighting and Sterilization Interlock Protection

    The interlock function helps prevent accidental activation of sterilization during operation, improving user convenience and operational safety.

  • Pre-filter Protection System

    The integrated pre-filter helps intercept larger particles and impurities, reducing the load on the high efficiency filter and supporting longer filter service life.

  • Easy Maintenance and Mobility

    The quick-change pre-filter design, backup socket, and universal casters with brakes provide convenient maintenance and flexible laboratory placement.

Applications

The AG1000 Laminar Flow Clean Bench is designed for laboratory workflows requiring a controlled clean airflow environment and reduced airborne particle contamination during sample handling procedures.

  • Sample Handling: Provides a controlled clean workspace for procedures requiring protection of samples from airborne particles.

  • Clean Laboratory Operations: Suitable for laboratory environments requiring ISO Class 5 cleanliness and stable airflow conditions.

  • Contamination-Controlled Procedures: Supports workflows where maintaining a clean working area and consistent airflow performance are required.

Configuration List

Item Quantity
Clean Bench 1
Power Cord 1
Product Manual, Test Report, etc. 1

FAQ

What is a Laminar Flow Clean Bench?

A Laminar Flow Clean Bench is a laboratory workstation designed to provide a controlled clean airflow environment through unidirectional airflow. It is commonly used for applications requiring sample protection and reduced airborne particle contamination.

What cleanliness level does the AG1000 Clean Bench provide?

The AG1000 provides an ISO Class 5 clean working environment, also classified as Class 100 cleanliness, for laboratory workflows requiring controlled clean conditions.

What applications is the AG1000 Laboratory Clean Bench suitable for?

The AG1000 Laboratory Clean Bench is suitable for laboratory applications requiring a controlled clean workspace, including sample handling, clean laboratory operations, and other contamination-controlled procedures.

What is the difference between a Clean Bench and a Biosafety Cabinet?

A Clean Bench is designed to provide a controlled, clean airflow environment primarily for protecting samples and maintaining workspace cleanliness. It does not provide the same biological containment functions as a Biosafety Cabinet.

Does the AG1000 Clean Bench have UV sterilization function?

Yes. The AG1000 includes UV sterilization functionality with appointment settings. Users can configure sterilization scheduling according to laboratory operation requirements.

How does the AG1000 maintain a stable clean airflow environment?

The AG1000 uses a uniform airflow design to provide clean airflow coverage throughout the working area. The system also provides airflow speed adjustment and real-time parameter display through the LCD control interface.

What material is used for the AG1000 work surface?

The AG1000 working surface is made of 304 stainless steel, providing corrosion resistance and an easy-to-clean surface for laboratory operations.

Can the AG1000 front glass window be adjusted?

Yes. The front window uses a manual lifting system with a 5 mm toughened glass panel. The window can be opened and positioned at different heights within the available travel range.

When can I expect my order to ship?

Most orders are filled and shipped within 2-3 business days from the time they are received.

Our standard shipping usually take 2-5 days.

We also provide express shippping for time-sensitive deliveries. 

Email contact@biofargo.com if you have any requirements.

 