You have no items in your shopping cart.
Product Description
SHENTEK® rcAAV Quantitation Kit is a qPCR-based kit for detection and quantitation of replication-competent adeno-associated virus (rcAAV) contamination in recombinant AAV (rAAV) serotypes designated as rAAV-2/N. The kit is designed to quantify rcAAV-2/N contamination in rAAV production samples including harvested cell-culture bulk, purified stocks and final products. The kit contains a T&R DNA control for preparation of an absolute quantitation standard curve, separate Target and Reference Primer & Probe mixes, qPCR reaction buffer and supporting reagents. The kit supports standard-curve (absolute) quantitation and is compatible with common qPCR platforms (e.g., ABI 7500, Bio-Rad CFX96, Roche 480, SHENTEK-96S).
Important: The ITR sequence of the rAAV test sample must match the provided ITR sequence for correct detection. Reagents supplied are sufficient for 2 × 100 reactions.
Technical Specifications
| Parameter | Details |
|---|---|
| Intended use | Quantitative detection of replication-competent AAV (rcAAV-2/N) contamination in rAAV-2/N samples by qPCR (absolute quantitation, standard curve) |
| Number of reactions (kit size) | Reagents for 2 × 100 reactions |
| Dynamic range / standard curve | 20 to 2 × 10^6 copies/µL (standard curve concentrations: ST6=2×10^1 to ST1=2×10^6 copies/µL) |
| Limit of quantification (LOQ) | 20 copies/µL (lowest standard used for quantitation) |
| Reaction volume | 30 µL total reaction volume (10–10.04 µL qPCR mix + 20 µL sample/standard per well) |
| Thermal cycling (example ABI 7500) | Pre-melt 95 °C 10:00 (1 cycle); Denature 95 °C 00:15; Anneal/extend 60 °C 00:30; Read at 72 °C 00:30; 40 cycles. (Note: ABI 7500 users set final read step to 72 °C 34 s.) |
| Detector channels / probes | Target-2 detected in FAM channel; Reference-2 detected in CY5 channel; separate primer/probe mixes provided |
| Ct threshold settings (recommended) | Reference-2 threshold = 0.06; Target-2 threshold = 0.02; use automatic baseline and manual Ct |
| Ct acceptance criteria | NTC Ct (Reference and Target) should be >35 or undetermined. NCS Ct values should be larger than mean Ct of lowest standard. |
| Contamination calculation | rcAAV contamination rate = (Detection value of Target genes) ÷ (Detection value of Reference genes × dilution factor ÷ 2). Note: each rAAV contains two copies of the Reference gene. |
| Compatible instruments | ABI 7500, Bio-Rad CFX96, SHENTEK-96S, Roche 480 and other real-time PCR systems (ROX usage depends on instrument) |
| Storage stability | Kit components can be stored under appropriate conditions for up to 24 months |
Features
- Designed for rcAAV-2/N detection: Specifically optimized to quantify replication-competent AAV contamination in rAAV-2/N serotypes using ITR-targeted assays.
- Absolute quantitation by standard curve: Includes T&R DNA Control and dilution scheme to generate a 6-point standard curve (2×10^1 – 2×10^6 copies/µL) for absolute quantitation.
- Complete assay components: Provides qPCR reaction buffer, Target and Reference primer/probe mixes, ROX option, DNA dilution buffer and DNA control for streamlined setup.
- Platform flexibility: Compatible with multiple real-time PCR instruments; ROX addition is optional depending on instrument model.
- Procedural controls and guidance: Includes NTC and NCS guidance, recommended plate layouts, Ct thresholds, and sample dilution recommendations to support robust QC workflows.
Applications
- Quantitation of rcAAV contamination in recombinant AAV production (rAAV stocks and final products)
- Quality control testing during rAAV manufacturing
- Analysis of harvested cell-culture samples for presence of replication-competent AAV
- Lot release and batch testing for rcAAV contamination
Kit Contents
Attention
• For Research Use Only (RUO). Not for use in diagnostic procedures.
• Read Material Safety Data Sheets (MSDS) and wear appropriate PPE (gloves, lab coat, eye protection, mask) when handling reagents.
• Prevent nucleic acid contamination: UV-treat surfaces, pipettes and tubes for 30 minutes and disinfect with 75% alcohol before setup.
• Benzonase nuclease treatment of rAAV stocks prior to extraction is required to remove non-encapsidated nucleic acids and improve direct-qPCR accuracy.
• Follow the SHENTEK Virus DNA & RNA Extraction Kit instructions for sample extraction when applicable.
• Thaw reagents at 2–8 °C or on ice, vortex and briefly centrifuge before use; protect light-sensitive reagents (reaction buffer) from light.
• Centrifuge the lyophilized DNA control at 12,000 rpm for 1 min and reconstitute precisely with 55 µL ddH2O before preparing dilutions.
• Prepare standard curve fresh (recommended six points) and run samples in triplicate for reliable quantitation.
• Add 100× ROX only if required by the qPCR instrument (ABI 7500 requires ROX; SHENTEK-96S and Roche 480 generally do not).
• Use recommended Ct threshold settings (Reference = 0.06; Target = 0.02) and check slope/intercept/R² of standard curve for assay validity.
Quality Management & Certifications
Quality System
Download QMSQMS (ISO, GMP)
Download CertificateQuality Advantages
View ReportQuality Control Process
Download ProcessTechnical Resources & Downloads
Frequently Asked Questions (FAQ)
Research Use Only
Research Use Only (RUO). For Research Use Only. Not for use in diagnostic procedures. – This product is intended for laboratory research purposes only and not for clinical or regulatory diagnostic use.
Not intended for use in USDA or FDA regulated diagnostic testing or official compliance testing.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.