Composition
Name | Article Number | Specification | Storage Conditions | Shelf Life |
MaxSortin® CD138 Separation Magnetic Beads | TL-811-1000 | 1 mL for 1×10⁹ total cells | 2 - 8 °C | 6 months |
MaxSortin® Cell Sorting Buffer | MS-BF100 | 100 mL | 2 - 8 °C | 12 months |
MaxSortin® L-Separation Column | MS-CL01 | 1 piece | 10 - 35 °C | 12 months |
Specification
Reactive Species | Human |
Endotoxin | <2EU/mL |
Appearance | Brown liquid |
Intended Use
MaxSortin® CD138 Separation Magnetic Beads can be used to sort CD138+ cells. By coupling anti-human CD138 monoclonal antibodies onto the magnetic beads, incubating them with cells, and then performing magnetic separation, the sorting of CD138+ cells can be achieved.
Experimental Procedures
-
Resuspend the mixed cell sample of PBMCs containing about 10% U266 in PBS buffer containing 1% human serum albumin (HSA). Take a sample for counting and transfer 1×10⁷ cells into a 1.5 mL Ep tube. Then centrifuge at 1500 rpm for 5 minutes.
-
Discard the supernatant, take 90 μL of MaxSortin® Cell Sorting Buffer solution to resuspend the cells, add 10 μL of MaxSortin® CD138 Separation Magnetic Beads, mix well and then place them in a refrigerator at 2 - 8 °C for incubation for 15 minutes.
-
Take the MaxSortin® L-Separation Column and place it on the magnetic-activated cell sorting (MACS) sorter, and rinse it twice with 1 mL of MaxSortin® Cell Sorting Buffer.
-
Take the sample that has completed incubation out of the refrigerator at 2 - 8 °C, add 1 mL of MaxSortin® Cell Sorting Buffer, centrifuge at 1500 rpm for 5 minutes, and discard the supernatant.
-
Add 1 mL of MaxSortin® Cell Sorting Buffer to resuspend the cells, add the sample into the MaxSortin® L-Separation Column. After it flows out naturally, add MaxSortin® Cell Sorting Buffer in two portions, 3 mL each time, to wash the cells adhering to the column.
-
After all the MaxSortin® Cell Sorting Buffer has flowed out, remove the MaxSortin® L-Separation Column from the MACS sorter and place it in a 15 mL centrifuge tube (mark it properly). Add 3 mL of MaxSortin® Cell Sorting Buffer into the MaxSortin® L-Separation Column and use the piston to push the liquid out directly. The collected cells are the CD138+ cells.
-
Count the cells and conduct flow cytometry detection.
Precautions
-
When incubating the magnetic beads with cells, it is necessary to mix them thoroughly to improve the sorting efficiency.
-
When the proportion of CD138+ cells is below 3%, it is recommended to add 5 μL of magnetic beads. When the proportion of CD138+ cells is above 3%, it is recommended to add 10 μL of magnetic beads.
-
This product cannot be used for clinical treatment.