$31.00

FREE
SHIPPING

100% MONEY
BACK GUARANTEE

ONLINE
SUPPORT 24/7

Availability:
AVAILABLE
In stock & estimated to ship in 3-7 days by July 08, 2026

Description

In modern HPLC and GC laboratory workflows, automated sample processing places increasing demands on vial consistency, injection stability, and system reliability. Variations in vial geometry, poor needle access, or inconsistent insert positioning can introduce avoidable interruptions in autosampler operation and reduce overall analytical efficiency.

High-throughput chromatography systems rely on stable and repeatable sample handling to maintain consistent injection performance across long analytical sequences. Issues such as needle stress during repetitive sampling, sample loss from poor vial fit, and variability in limited-volume handling can directly impact workflow continuity and data consistency.

This 2 mL Amber Glass HPLC Autosampler Vial (12×32 mm Screw Thread) is designed to support routine chromatographic sample handling in automated environments where operational stability, sample protection, and consistent injection performance are required. The amber glass format supports light-sensitive sample handling, while the vial geometry is optimized for standard autosampler compatibility and reproducible laboratory workflows.

Specification

SKU HPLC-112207
Description Amber Glass Screw Thread Vials, HPLC Autosampler Vials
Size 12*32mm with a 9mm diameter
Height 32mm
Width 12mm
Cap Size 12mm
Capacity 2ml
Color Amber
Material Borosilicate Glass
Graduations Yes
Glass Properties Acid-resistant, alkali-resistant, and high-temperature resistant
Temperature Resistance -60°C to 200°C
Marking Spot Yes
Volume (Working) 1.8ml
Closure Type Screw
Quantity 100/PK
Base Style Flat Bottom

 

Features

  • 2 mL amber glass HPLC autosampler vials for chromatography workflows

  • 12×32 mm standard screw thread vial format for automated injection systems

  • Large opening design improves needle access and reduces breakage risk

  • Step vial structure improves insert centering accuracy in vial neck

  • Borosilicate glass material provides chemical and thermal resistance

  • Graduated marking spot supports sample tracking and identification

  • Available silanized option for reduced adsorption in sensitive assays

Applications

  • HPLC (High Performance Liquid Chromatography) analysis

  • GC and GC autosampler injection workflows

  • LC-MS sample preparation and analysis

  • Pharmaceutical quality control (QC) testing

  • Environmental analytical chemistry testing

  • Biochemical and metabolite profiling

  • High-throughput autosampler sample screening

Autosampler Compatibility

  • Waters 717Plus
  • Waters Acquity
  • Waters CapLC
  • Waters WISP
  • Shimadzu AOC14/1400
  • Shimadzu AOC-20
  • Shimadzu AOC88/9
  • Shimadzu AOC-5000
  • Shimadzu LC 2010
  • Shimadzu SIL-HT/10ADVP
  • Thermo Fisher Scientific / DIONEX A-200s/AS 150/800/8000
  • Thermo Fisher Scientific / DIONEX AS 3000/TRACE GC
  • Thermo Fisher Scientific / DIONEX ASI-100
  • Thermo Fisher Scientific / DIONEX SURVEYOR LC
  • Thermo Fisher Scientific / DIONEX TriPlus
  • Thermo Fisher Scientific / DIONEX WPS-3000RS
  • Thermo Fisher Scientific / DIONEX WPS-3000SL
  • Techcomp / Varian 8034/8035/8100/8200
  • Techcomp / Varian 9095/9100
  • Techcomp / Varian CP-84100
  • Perkinelmer Autosystem GC/XL/AS-2000
  • Perkinelmer Claru 500/600
  • Perkinelmer Integral 4000
  • Perkinelmer ISS-100/200
  • CTC Analytics Combipal
  • Agilent 1050
  • Agilent 1090
  • Agilent 1100
  • Agilent 1200
  • Agilent 1260 G1329B
  • Agilent 1290
  • Agilent 79855(A)
  • Agilent CTC HTS+HTC PAL
  • Agilent 5880
  • Agilent 5890
  • Agilent 6850
  • Agilent 6890
  • Agilent 7673A
  • Agilent 7683A
  • Agilent 7820A
  • Agilent 790AA
  • Agilent 7890B
  • Agilent CTC GC PAL

Frequently Asked Questions

What are these HPLC autosampler vials designed for?

These 2 mL amber glass vials are designed for HPLC autosampler use, including sample storage and injection in chromatography workflows.

What is the benefit of the large opening design?

The large opening design provides a 40% larger target area, as described in the product specification, and is designed to eliminate broken needles due to the increased target area.

What materials are these autosampler vials made of?

The vials are made of borosilicate glass and are available in amber color.

What is the step vial design used for?

The step vial design precisely centers a limited volume insert in the neck of the vial.

Are marking and graduation features available on these vials?

Yes. The vials are available with a graduated marking spot and include graduations as specified in the product details.

Are these vials available in different material options?

Yes. The product description indicates that vials are available in clear or amber borosilicate glass.

What closure type is used for these vials?

The closure type for these vials is screw thread.

What is the packaging quantity of these vials?

The packaging quantity is 100 per pack (100/PK).

What is the compatibility information for these autosampler vials?

The vials are compatible with the autosampler systems listed in the product compatibility section, including Waters, Shimadzu, Thermo Fisher Scientific / DIONEX, Agilent, PerkinElmer, CTC Analytics, and Techcomp / Varian systems as provided in the product details.

When can I expect my order to ship?

Most orders are filled and shipped within 2-3 business days from the time they are received.

Our standard shipping usually take 2-5 days.

We also provide express shippping for time-sensitive deliveries. 

Email contact@biofargo.com if you have any requirements.

 

Terms and Conditions