You have no items in your shopping cart.
Description
Pyrogallol is sensitive to air and light and may become grayish or darker after exposure. Laboratories handling this material therefore need a clearly defined assay specification, controlled impurity limits, and appropriate storage guidance when selecting and using the reagent.
PC6880 is reagent-grade pyrogallol, also known as 1,2,3-trihydroxybenzene, with an assay specification of ≥99.8%. Its product specification defines limits for residue after ignition, chloride, sulfate, iron, and heavy metals as lead.
This laboratory research reagent should be kept in a tightly closed container in a cool, dry, well-ventilated area. Protect the material from light and minimize unnecessary exposure to air. Review the Safety Data Sheet before handling.
Specification
| Product Name | Pyrogallol (1,2,3-Trihydroxybenzene) |
| Product Code | PC6880 |
| CAS No. | 87-66-1 |
| EC No. | 201-762-9 |
| Grade | Reagent |
| Molecular Formula | C6H3(OH)3 |
| Molecular Weight | 126.11 |
| Assay | ≥99.8% |
| Appearance | White powder; may become grayish upon exposure to air and light |
| Melting Point | 131–135°C |
| Boiling Point | 309°C |
| pH | 5.8 at 10 g/L |
| Density | 1.450 g/cm³ at 20°C |
| Solubility | Soluble |
| Residue after Ignition | ≤0.005% |
| Chloride (Cl) | ≤0.001% |
| Sulfate (SO4) | ≤0.005% |
| Heavy Metals (as Pb) | ≤5 ppm |
| Iron (Fe) | ≤0.001% |
| Storage | Room temperature; tightly closed, cool, dry, well ventilated, and protected from air and light |
| Package Size | 100 g |
Features
- Defined Assay Specification: Reagent-grade pyrogallol with an assay specification of ≥99.8%.
- Controlled Heavy Metals: Heavy metals, calculated as lead, are specified at ≤5 ppm.
- Controlled Iron Content: Iron is specified at ≤0.001%.
- Defined Anion Limits: Chloride is specified at ≤0.001%, and sulfate is specified at ≤0.005%.
- Low Ignition Residue: Residue after ignition is specified at ≤0.005%.
- Documented Storage Precautions: The product documentation identifies pyrogallol as sensitive to air and light.
Applications
- Laboratory Research: For research workflows that specify pyrogallol or 1,2,3-trihydroxybenzene as a laboratory reagent.
- Defined-Purity Research Workflows: The ≥99.8% assay specification provides a defined selection parameter for laboratory methods requiring reagent-grade pyrogallol.
- Controlled-Impurity Reagent Selection: The product specification provides limits for heavy metals, iron, chloride, sulfate, and residue after ignition.
- Method-Specific Evaluation: Users should determine whether PC6880 is suitable for their intended laboratory method and experimental conditions.
Handling and Storage
Pyrogallol absorbs oxygen from the air and may darken after exposure. The product documentation also identifies the material as light sensitive.
Store PC6880 at room temperature in a tightly closed container in a cool, dry, well-ventilated area. Protect it from light, minimize exposure to air, and keep it away from incompatible materials.
- Minimize dust generation and accumulation.
- Use only with adequate ventilation.
- Avoid contact with eyes, skin, and clothing.
- Wear appropriate protective gloves, protective clothing, and eye protection.
- Review the complete SDS before handling, storage, spill response, or disposal.
Signal Word: Danger.
Documents
FAQ
What is Pyrogallol PC6880?
PC6880 is reagent-grade pyrogallol, also known as 1,2,3-trihydroxybenzene. Its CAS number is 87-66-1, its molecular formula is C6H6O3, and its molecular weight is 126.11.
What is the assay specification for this reagent-grade pyrogallol?
PC6880 has an assay specification of ≥99.8%. The specification also defines limits for residue after ignition, chloride, sulfate, iron, and heavy metals as lead.
What impurity limits are specified for PC6880?
Residue after ignition is specified at ≤0.005%, chloride at ≤0.001%, sulfate at ≤0.005%, iron at ≤0.001%, and heavy metals as lead at ≤5 ppm.
Why can pyrogallol become grayish or darker?
Pyrogallol is sensitive to air and light. The supplied documentation states that it may become grayish or darken after exposure and that it absorbs oxygen from the air.
How should Pyrogallol PC6880 be stored?
Store it at room temperature in a tightly closed container in a cool, dry, well-ventilated area. Protect the material from light and minimize unnecessary exposure to air.
What protective equipment is recommended when handling pyrogallol?
The SDS recommends appropriate protective gloves, protective clothing, and protective eyeglasses or chemical safety goggles. Adequate ventilation should be used, and dust generation should be minimized.
Is PC6880 intended for human or animal use?
No. PC6880 is for laboratory research use only and is not intended for human or animal drug, diagnostic, or therapeutic use.
Is Pyrogallol PC6880 regulated for transport?
The supplied SDS lists the product as not regulated under its transport information section.
Where can I find the COA and SDS for PC6880?
The original COA and SDS links are provided in the Documents section. Review the SDS for detailed hazard, handling, storage, first-aid, disposal, and transport information.
For laboratory research use only. Not for human or animal drug, diagnostic, or therapeutic use.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.