You have no items in your shopping cart.
Request Your Custom Quote Today
Tell us your required quantity and application needs to receive a tailored quotation for this product.
Description
Laboratories may need to run different real-time PCR programs without waiting for one full 96-well experiment to finish. The SLAN®-96P 96-well real-time PCR system addresses this workflow requirement with two independent 48-well reaction modules. Users can run two separate 48-well experiments with different amplification programs or operate the system as one 96-well experiment.
This dual-block real-time PCR system combines a 2 × 48-well format with a sample volume of 15–100 µL and compatibility with 0.2 mL PCR tubes. Its temperature control system provides a 4–99°C operating range, a maximum heating and cooling rate of 4.0°C/s, temperature uniformity of ±0.1°C, and temperature accuracy of ±0.1°C.
For laboratories performing multiplex real-time PCR, the SLAN®-96P supports four standard fluorescence channels and up to six channels with optional configurations. Compatible probes and dyes include FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425. The system supports six-target fluorescence detection without cross-interference correction and does not require internal reference dye correction.
The SLAN®-96P also supports high-resolution melting analysis. Its software covers qualitative analysis, absolute quantification, standard melting curves, endpoint allele identification, melting-curve genotyping, and high-resolution melting curves. Experimental data can be exported in XLSX, CSV, and TXT formats.
Specification
| Product Name | SLAN®-96P Real-Time PCR System |
|---|---|
| Model | SLAN®-96P |
| Sample Capacity | 96 wells, configured as two 48-well reaction modules |
| Reaction Modes | Two independent 48-well experiments or one 96-well experiment |
| Sample Volume | 15–100 µL |
| Compatible Consumables | 0.2 mL PCR tubes |
| Detection Sensitivity | Minimum resolution of 1 copy |
| Linear Range | 100–1010 copies |
| Repeatability | CV <1.00% |
| Sample Linearity | |r| ≥0.9990 |
| Internal Reference Dye Correction | Not required |
| Fluorescence Detection | Up to six-target detection without cross-interference correction |
| HRM Analysis | Supported |
| Reaction Module Type | Dual-slot, dual-module design |
| Temperature Control Method | Semiconductor thermoelectric module |
| Temperature Control Modes | Block control and tube control |
| Temperature Range | 4–99°C |
| Maximum Heating and Cooling Rate | 4.0°C/s |
| Temperature Uniformity | ±0.1°C |
| Temperature Accuracy | ±0.1°C |
| Heated Lid | Automatic heated lid |
| Excitation Source | Maintenance-free LED |
| Detector | High-sensitivity photoelectric sensor |
| Data Export Formats | XLSX, CSV, and TXT |
| Custom Reports | Supported |
| Operating System | Microsoft Windows XP, Vista, 7, 8, 10, 11, and later versions |
| Minimum Computer Memory | 4 GB |
| Minimum Hard Drive Capacity | 40 GB |
| Power Input | 220 VAC, 50 Hz |
| Maximum Power | 850 VA |
| Interfaces | RS232 and USB |
| Dimensions | 386 × 520 × 250 mm (W × D × H) |
| Weight | 18 kg |
| Warranty | 18-month free warranty |
Fluorescence Channels
| Channel | Compatible Probes and Dyes | Excitation Wavelength | Detection Wavelength | Configuration |
|---|---|---|---|---|
| Channel 1 | FAM / SYBR Green | 470 nm | 510 nm | Standard |
| Channel 2 | VIC / HEX / JOE / TET / TAMRA / Cy3 | 530 nm | 565 nm | Standard |
| Channel 3 | ROX / Texas Red | 585 nm | 620 nm | Standard |
| Channel 4 | CY5 | 630 nm | 665 nm | Standard |
| Channel 5 | Quasar 705 | 690 nm | 705 nm | Optional |
| Channel 6 | Atto 425 | 420 nm | 470 nm | Optional |
Features
Independent 2 × 48-Well Operation
The SLAN®-96P has two independent 48-well reaction modules. Laboratories can run two experiments with different amplification programs or use the system for one 96-well experiment.
Precise Temperature Control
Point-by-point temperature compensation provides ±0.1°C well-to-well temperature uniformity. The system also provides ±0.1°C temperature accuracy and a maximum heating and cooling rate of 4.0°C/s.
Maintenance-Free Fluorescence Detection
The optical system uses a high-power, maintenance-free LED excitation source and a high-sensitivity photoelectric detector. Fluorescence is collected from the side of the reaction tube.
No Internal Reference Dye Correction
The optical design provides consistent fluorescence detection across sample wells without an edge effect. Internal reference dye correction is not required.
Up to Six Fluorescence Channels
The 96-well qPCR instrument supports four standard fluorescence channels. Channels 5 and 6 are optional, allowing the system to be configured for up to six-channel multiplex real-time PCR detection.
Automatic Gain Selection
The system automatically selects the optimal gain according to the measured fluorescence value, without requiring manual gain adjustment.
High-Resolution Melting Support
The SLAN®-96P combines its optical and temperature performance with software analysis algorithms for high-resolution melting curve analysis. Both step and continuous scanning modes are supported.
Open Reagent and Consumables Platform
The system uses an open reagent and consumables platform and is compatible with 0.2 mL PCR tubes.
Flexible Data Management
The software can import patient and plate information from LIMS or a sample-preparation system. It also supports custom data export formats, custom report templates, and XLSX, CSV, and TXT data export.
Multi-Instrument Control
The software can control multiple SLAN-48P, SLAN-96S, and SLAN-96P instruments at the same time.
Application
- Qualitative real-time PCR analysis
- Absolute quantitative PCR analysis
- Standard melting curve analysis
- Endpoint allele identification
- Melting-curve genotyping
- High-resolution melting curve analysis
- Multicolor fluorescence detection
- Multi-gene testing using multi-tube settings
FAQ
What is the sample capacity of the SLAN®-96P real-time PCR system?
The SLAN®-96P has a total capacity of 96 wells. Its reaction area consists of two 48-well modules.
Can the two 48-well reaction modules run independently?
Yes. The two modules can independently run experiments with different amplification programs. They can also be used together for one 96-well experiment.
What reaction volume does the SLAN®-96P support?
The supported sample volume is 15–100 µL.
Which PCR consumables are compatible with this 96-well qPCR instrument?
The system is compatible with 0.2 mL PCR tubes.
How many fluorescence channels does the SLAN®-96P support?
The system has four standard fluorescence channels. Channel 5 for Quasar 705 and channel 6 for Atto 425 are optional.
Which fluorescent probes and dyes are supported?
The listed probes and dyes are FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425. Quasar 705 and Atto 425 require the optional fifth and sixth channels.
Does the SLAN®-96P support multiplex real-time PCR?
Yes. The system supports up to six-target fluorescence detection without cross-interference correction when configured with six detection channels.
Does this real-time PCR system support HRM analysis?
Yes. The SLAN®-96P supports high-resolution melting curve analysis, including step and continuous scanning modes.
Is ROX or another internal reference dye correction required?
No. The manufacturer states that internal reference dye correction is not required.
What are the temperature performance specifications?
The temperature range is 4–99°C. The maximum heating and cooling rate is 4.0°C/s, temperature uniformity is ±0.1°C, and temperature accuracy is ±0.1°C.
What is the detection sensitivity of the SLAN®-96P?
The stated minimum resolution is 1 copy. The stated linear range is 100–1010 copies, with repeatability of CV <1.00% and sample linearity of |r| ≥0.9990.
Which analysis functions are included in the software?
The software supports qualitative analysis, absolute quantification, standard melting curves, endpoint allele identification, melting-curve genotyping, and high-resolution melting curve analysis.
Which data export formats are supported?
Experimental data can be exported in XLSX, CSV, and TXT formats. Custom reports are also supported.
Can the SLAN®-96P connect with a LIMS?
The software can import patient and plate information from a LIMS or sample-preparation system.
What is the warranty period for the SLAN®-96P?
The stated free warranty period is 18 months.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.