You have no items in your shopping cart.
For Research Use Only (RUO)
Product Description
SHENTEK® CAR/TCR Transgene Copy Number Quantitation Kit is designed to quantify the copy number of target genes in human cell products derived from common HIV-1 lentiviral vectors (e.g., CAR or TCR genes integrated in CAR-T and TCR-T cell genomes). The kit uses a multiplex qPCR assay to detect DNA sequences related to the integration/expression elements on the transfer plasmid and a Single Copy Gene (SCG) in human cells, enabling calculation of average copies of target gene per cell. The kit includes a company-produced reference standard and an internal positive control (IPC). The assay is intended for rapid, specific, reliable and universal lentiviral vector applications. For Research Use Only.
Technical Specifications
| Parameter | Details |
|---|---|
| Product number | SK030221CA100 |
| Intended reactions | Reagents for 100 reactions |
| Reference standard initial concentration | CAR/TCR Control initial copy number: 2.33 × 10^8 copies/μL |
| Standard curve serial dilutions (copies/μL) | ST1: 2.33 × 10^6; ST2: 2.33 × 10^5; ST3: 2.33 × 10^4; ST4: 2.33 × 10^3; ST5: 2.33 × 10^2 |
| Reaction volume | Total reaction volume 30 μL (20 μL qPCR MIX + 10 μL template) |
| qPCR MIX composition (per reaction) | qPCR Reaction Buffer 15.9 μL; CAR/TCR Primer & Probe MIX 2.8 μL; IPC MIX 1.3 μL (total 20 μL) |
| Thermal cycling program | Activation 95 °C 10:00 (1 cycle); Denaturation 95 °C 00:15 (40 cycles); Annealing/Extension 60 °C 01:00 (fluorescence read) |
| Reporter dyes / targets | CAR/TCR target: FAM; SCG: CY5; IPC: VIC; ROX as passive reference |
| Ct / analysis settings | Manual Ct threshold 0.02; Automatic baseline; verify slope/intercept/R² for standard curve |
| Acceptance criteria for IPC | Mean Ct-IPC of sample should be within ±1.0 of the NCS Ct-IPC; significant increase indicates inhibition |
| Recommended DNA input per well | Recommended 5 ng to 30 ng total DNA per well (adjust based on preliminary experiments) |
| Calculation formula | CAR or TCR copies/cell = 2 × (CAR or TCR / SCG) |
| Sample types | Purified genomic DNA from CAR-T, TCR-T or other cells with lentiviral integration |
Features
- Multiplex absolute quantitation: Simultaneous detection of CAR/TCR target, single copy gene (SCG) and IPC in the same reaction for absolute copy number determination using a standard curve.
- Reference standard included: Proprietary reference standard supplied and pre-dilution scheme provided for a 5-point standard curve.
- Ready-to-use primer & probe mixes: Pre-formulated CAR/TCR Primer & Probe MIX and IPC MIX simplify assay setup and reduce pipetting error.
- Compatible with common qPCR platforms: Validated for use on SHENTEK-96S, ABI 7500, LineGene 9600plus, CFX96 and similar real-time PCR instruments.
- Designed for lentiviral vector applications: Optimized for quantifying transgene copy numbers from HIV-1 derived lentiviral vectors (CAR/TCR).
Applications
- Quantification of CAR or TCR transgene copy number in CAR-T and TCR-T cell products
- Lentiviral vector integration assessment
- Preclinical and research cell therapy product characterization
- Quality control and batch testing for gene-modified cell products (research use)
Kit Contents
Attention
• For Research Use Only (RUO). Not for use in diagnostic procedures.
• Read Material Safety Data Sheets (MSDS) and follow handling instructions; wear protective eyewear, mask, clothing and gloves.
• Work in a clean environment: irradiate bench, pipettes and tubes with UV for 30 minutes and disinfect with 75% ethanol to avoid contamination.
• Avoid assay inhibitors; monitor IPC Ct — if sample IPC Ct is significantly higher than NCS IPC Ct, sample may be inhibitory.
• NTC and NCS Ct should be larger than the mean Ct of the lowest standard concentration.
• Prepare and run triplicates for standards, NTC, NCS and test samples where possible.
• Recommended sample input per well: 5 ng–30 ng total DNA (optimize as needed).
• Store kit components as labeled (-20 °C) and protect from light; kit stable up to 24 months. If DDB is cloudy, heat to 37 °C until clear.
• Seal plates/tubes, mix and briefly centrifuge before running; follow instrument-specific setup and analysis instructions.
Quality Management & Certifications
Quality System
Download QMSQMS (ISO, GMP)
Download CertificateQuality Advantages
View ReportQuality Control Process
Download ProcessTechnical Resources & Downloads
Frequently Asked Questions (FAQ)
Research Use Only
Research Use Only (RUO) – This product is intended for laboratory research purposes only and not for clinical or regulatory diagnostic use.
Not intended for use in USDA or FDA regulated diagnostic testing or official compliance testing.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.