$89.00

FREE
SHIPPING

100% MONEY
BACK GUARANTEE

ONLINE
SUPPORT 24/7

Sku: SA2800-1mL
Availability:
QUICK SHIP
In stock & estimated to ship in 1-2 days by June 06, 2026

Description

SA2800 Streptavidin Magnetic Beads are 2800 nm streptavidin-conjugated magnetic particles designed for rapid and efficient capture of biotinylated molecules. A high-performance conjugation technology is employed to fully functionalize the bead surface with natural streptavidin, enhancing the capture capacity for biotin-labeled targets while reducing background signals.

The streptavidin-coated magnetic beads exhibit excellent surface uniformity, strong biotin-binding affinity, outstanding reproducibility, and efficient liquid-phase reaction kinetics. The magnetic beads can bind various biotinylated complexes, including peptides, proteins, antibodies, carbohydrates, lectins, and oligonucleotide DNA/RNA.

With 1000 pmoles of free biotin binding capacity per mg, 400 pmoles of biotinylated oligonucleotide capacity, and 15 μg of biotinylated antibody capacity, SA2800 magnetic beads are suitable for nucleic acid purification, molecular and immuno-diagnostics, cell sorting, cDNA expression library construction, and drug screening workflows.

Specifications

Parameter Specification
Bead Size 2800 nm
Bead Type Streptavidin magnetic beads
Coating Material Polystyrene
Surface Functionalization Natural streptavidin coating
Solid Content 10 mg/mL
Biotin Binding Capacity 1000 pmoles free biotin / mg beads
Oligonucleotide Binding Capacity 400 pmoles biotinylated oligonucleotides / mg beads
Antibody Binding Capacity 15 μg biotinylated antibodies / mg beads
Storage Buffer 10 mM PBS (pH 7.4) containing 0.02% Proclin300 and 0.02% Tween 20
Storage Condition 2–10°C
Shelf Life 24 months
Product Packaging 1 mL, 5 mL, 20 mL

 

Applications

  • Nucleic acid purification — capture and separation of biotinylated DNA/RNA molecules
  • Immuno-diagnostics — magnetic solid phase for antibody-based detection workflows
  • Cell sorting — affinity isolation of labeled cell populations
  • Protein purification — purification of biotinylated proteins and peptides
  • Drug screening — biotin-based molecular interaction studies
  • cDNA expression library construction — capture of biotinylated oligonucleotide complexes

Storage

The magnetic beads are suspended in 10 mM PBS buffer (pH 7.4) containing 0.02% Proclin300 and 0.02% Tween 20.

Storage Condition: Store at 2–10°C.

Shelf Life: 18 months.

Storage Notes: Keep the container of magnetic beads in an upright position. This ensures that settled beads remain immersed in the solution, preventing bead adhesion to the tube wall (which would cause dehydration and loss of biological activity). Avoid freezing, as freezing may lead to reduced bead activity.

Binding Capacity

1 mg of streptavidin magnetic beads can bind to:

  • 1000 pmoles of free biotin

  • 400 pmoles of biotinylated oligonucleotides

  • 15 μg of biotinylated antibodies

The binding capacity for double-stranded DNA depends on the length of the DNA fragments.

Principle

As a solid-phase matrix, streptavidin-conjugated magnetic beads can bind to various biotinylated complexes (such as small-molecule peptides, proteins, antibodies, carbohydrates, lectins, and oligonucleotide DNA/RNA) in a simple, rapid, and efficient manner. Therefore, they are applicable in fields including molecular and immuno-diagnostics, cell sorting, construction of cDNA expression libraries, and drug screening.

Precautions

  • The binding capacity of streptavidin magnetic beads is related to the size of the specific target molecule.

  • Ensure there is no excessive free biotin in the sample, as free biotin binds to streptavidin more easily than large-molecular-weight target molecules.

  • For PCR product solutions amplified with biotinylated primers, try to remove free biotinylated primers before binding to the magnetic beads — this is because biotin-labeled primers have higher binding affinity to magnetic beads than biotinylated DNA fragments. Free biotinylated primers can be removed via ultrafiltration, microdialysis, or general DNA purification and recovery methods.

  • It is recommended to optimize the dosage of magnetic beads through titration in each application. Both the size of the ligand molecule and the degree of biotinylation may affect their binding capacity. The ratio of magnetic beads to biotinylated ligands directly impacts the overall experimental results: with a constant amount of magnetic beads, when the concentration of biotinylated ligands is low, the target-binding capacity of the bead–ligand complex increases as the concentration of biotinylated ligands rises; however, once saturation adsorption is reached, further increasing the concentration of biotinylated ligands will not improve the target-binding capacity of the bead–ligand complex.

  • For the preparation of biotinylated ligands, biotinylation reagents produced by manufacturers such as Pierce or Sigma are recommended. Biotin labeling can be applied to various functional groups, including amines, thiols, carboxyls, carbohydrates, tyrosine/histidine side chains, guanidines, and cytosine bases. Note that biotinylation may lead to the loss of target molecule activity, so precautions should be taken based on specific applications.

  • In DNA synthesis, biotin is generally labeled at the 5′-end of oligonucleotide primers. For protein biotinylation, reagents such as biotin-X-NHS ester (from Pierce or Sigma) can be used.

  • After the magnetic beads bind to the ligand, when using the ligand to capture the target substance, ensure that the target substance is free in the solution and that its binding sites to the ligand are exposed.

Operational Procedures (For Reference)

A. Magnetic Bead Preparation

1. Before use, vortex the magnetic bead suspension thoroughly (ultrasonic dispersion can also be used: carefully place the test tube in a standard ultrasonic cleaner and sonicate for approximately 3 minutes). Use a pipette to transfer the required volume of magnetic beads into a centrifuge tube.

2. Place the centrifuge tube on a magnetic rack; separation is typically complete within approximately 1 minute. Use a pipette to remove the liquid.

3. Add the washing solution specified for the experiment, cap the test tube, and mix well by vortexing. Then, perform magnetic separation and remove the liquid.

4. Repeat the washing step 1–2 times, and resuspend the magnetic beads in an appropriate volume of solution.

For antibody- or protein-related experiments: Wash the streptavidin (SA) magnetic beads 2–3 times with PBS or physiological saline buffer before use.

For nucleic acid-related experiments: Wash the SA magnetic beads with 1× B&W Buffer at least 3 times before use.

Formulation of 2× B&W Buffer: 10 mM Tris-HCl (pH 7.5), 1 mM EDTA, 2 M NaCl.

This product does not contain ribonuclease (RNase). For RNA-related experiments, pre-treat the SA magnetic beads to remove RNase:
Wash the SA magnetic beads twice with Wash Buffer I (Wash Buffer I: DEPC-treated 0.1 M NaOH, DEPC-treated 0.05 M NaCl), 2 minutes per wash. Then wash once with Wash Buffer II (DEPC-treated 0.1 M NaCl), and finally resuspend the SA magnetic beads in Wash Buffer II.

B. Binding to Biotinylated Ligands

1. Binding of Streptavidin Magnetic Beads to Biotin–Antibody or Biotin–Peptides

Calculate the required amounts of magnetic beads and biotinylated antibody. Each mg of streptavidin magnetic beads can bind a maximum of 15 μg of antibody or 300 pmol of biotinylated peptide; saturation levels of antibody/peptide are generally not required.

After resuspending the magnetic beads, incubate them with the biotinylated antibody at room temperature for 30 minutes, mixing by rotation.

After incubation, place the centrifuge tube on a magnetic rack for 2 minutes and remove the supernatant.

Wash the magnetic beads 4–5 times with PBS/BSA.

Resuspend and dilute the magnetic beads to the desired concentration for downstream experiments.

2. Binding of Streptavidin Magnetic Beads to Nucleic Acids

Take an appropriate amount of pre-washed magnetic beads.

Resuspend the magnetic beads in 2× B&W Buffer to a final concentration of 1 μg/μL or a concentration suitable for the experiment.

Add an equal volume of biotinylated DNA/RNA solution.

At room temperature, mix by rotating or gently tapping the centrifuge tube.

Incubate for approximately 10 minutes for ~30 bp fragments, and 15 minutes for ~1 kb fragments.

After incubation, place the centrifuge tube on a magnetic rack for 1–2 minutes and remove the liquid.

Wash the magnetic beads 2–3 times with 1× B&W Buffer.
Finally, resuspend the magnetic beads in a solution suitable for downstream experiments and dilute to the desired concentration.

C. Dissociation of Streptavidin Magnetic Beads from Antibodies/Proteins and Nucleic Acids

1. Elution of Biotin-Labeled Antibodies/Proteins

Two elution protocols are provided below; select the appropriate method based on the requirements of subsequent detection.

a. Denaturing Elution (for SDS–PAGE Detection)

Procedure: Add 50–100 μL of 1× SDS-PAGE Loading Buffer to the magnetic beads, mix well, and heat at 95°C for 5 minutes. Place on a magnetic rack to separate the magnetic beads, collect the supernatant, and perform SDS-PAGE detection.

Note: If denaturing elution is selected, the eluate will contain streptavidin monomers, streptavidin multimers, and biotin-labeled antibodies/proteins.

b. Non-Denaturing Elution (for Preserving Biological Activity)

This method maintains the native biological activity of the eluted sample, enabling subsequent functional analysis.

Procedure: Add 50–100 μL of Elution Buffer II to the magnetic beads, and incubate at room temperature for 5–10 minutes. Place on a magnetic rack to separate the magnetic beads, collect the supernatant into a new EP tube, and immediately add neutralization buffer (0.1 M NaOH) at 1/10 of the total volume to adjust the pH of the eluate to neutral. The sample is then ready for subsequent functional analysis.

Note: For non-denaturing elution, streptavidin may dissociate under acidic conditions — do not exceed 10 minutes of incubation. Acidic elution buffer disrupts most antibody–antigen interactions; for better elution efficiency, pre-wash the magnetic beads once with 1 mL of 0.1% Tween-20 aqueous solution.

Elution of Biotin-Labeled Nucleic Acids

Procedure: Add 50–100 μL of Elution Buffer (95% formamide, 10 mM EDTA, pH 8.2) to the magnetic beads. Incubate at 65°C for 5 minutes or 90°C for 2 minutes. Place on a magnetic rack for magnetic separation, and collect the supernatant.

FAQ

Q: What is the biotin binding capacity of SA2800 streptavidin magnetic beads?
A: 1 mg of SA2800 beads can bind approximately 1000 pmoles of free biotin, 400 pmoles of biotinylated oligonucleotides, and 15 μg of biotinylated antibodies.

Q: What is the particle size of SA2800 magnetic beads?
A: SA2800 streptavidin magnetic beads have a particle size of 2800 nm.

Q: What applications are SA2800 beads suitable for?
A: SA2800 beads are suitable for nucleic acid purification, immuno-diagnostics, cell sorting, protein purification, and drug screening workflows.

Q: How quickly can magnetic separation be completed?
A: Magnetic separation is typically completed within approximately 1 minute using a standard magnetic rack.

Q: Can SA2800 streptavidin magnetic beads be frozen?
A: No. Freezing may reduce magnetic bead activity and should be avoided.

Related Streptavidin Magnetic Beads

SA200 Streptavidin Beads

Bead Size: 200 nm

View Product

SA500 Streptavidin Beads

Bead Size: 500 nm

View Product

SA1000 Streptavidin Beads

Bead Size: 1000 nm

View Product

Documents

User Manual

Application Performance Data

When can I expect my order to ship?

Most orders are filled and shipped within 2-3 business days from the time they are received.

Our standard shipping usually take 2-5 days.

We also provide express shippping for time-sensitive deliveries. 

Email contact@biofargo.com if you have any requirements.

 

Terms and Conditions