For Research Use Only (RUO)

$876.00

FREE
SHIPPING

100% MONEY
BACK GUARANTEE

ONLINE
SUPPORT 24/7

Availability:
AVAILABLE
In stock & estimated to ship in 3-7 days by October 13, 2026
Detection Method
ELISA
Assay Time
Refer to manual
Storage Temperature
2-8 °C (unopened; opened components: strips 60 days, reconstituted standard 30 days)

Product Description

This SHENTEK MDCK HCP ELISA Kit is a one-step, solid-phase, double-antibody sandwich ELISA for quantitative detection of residual host cell proteins (HCPs) from MDCK (Madin–Darby canine kidney) cells. A sheep polyclonal anti-MDCK HCP affinity-purified capture antibody is coated on microtiter strips and an HRP-conjugated sheep anti-MDCK HCP detection antibody (used simultaneously with standards/samples) enables colorimetric detection with TMB/H2O2 substrate. After incubation and washing, HRP catalyzes TMB oxidation (blue, max absorbance ~655 nm) and reaction is stopped to give a yellow product read at 450 nm (with 620–650 nm reference). Sample HCP concentrations are interpolated from a 4‑parameter logistic (4‑PL) calibration curve constructed from supplied calibration standards.

Designed for research use only (not for clinical use). Supplied as a 96-test kit with pre-coated microtiter strips, lyophilized calibration standard, HRP-conjugated detection antibody (100×), buffers and substrates. Typical application includes in-process testing and final product testing for MDCK-derived biologics including vaccines and influenza virus products.

Technical Specifications

Parameter Details
Kit format / throughput 96 tests/Kit (8 wells × 12 strips)
Assay principle One-step double-antibody sandwich ELISA, colorimetric detection (TMB, read at 450 nm with 620–650 nm reference)
Linearity & Range 2–200 ng/mL (4‑PL curve), R2 ≥ 0.990 (typical R2 reported 0.9994)
Lower limit of quantitation (LLOQ) 2 ng/mL
Calibration Eight-point calibration curve (ST1–ST8) with 4‑parameter logistic (4‑PL) regression; example 4‑PL parameters: A=9.57058, B=-1.04748, C=399.32097, D=0.00304, R2=0.9994
Typical OD data (reference) Example OD450–620nm averages: 200 ng/mL = 3.237; 100 ng/mL = 1.931; 50 ng/mL = 1.089; 25 ng/mL = 0.610; 10 ng/mL = 0.312; 5 ng/mL = 0.210; 2 ng/mL = 0.148; 1 ng/mL = 0.133; 0 ng/mL = 0.111
Specificity / Cross-reactivity No cross-reactivity observed with E. coli, Pichia pastoris, or Sf9 cell HCPs
Sample types In-process samples, harvested bulk, drug substance, drug product from MDCK-based processes
Recommended sample pH pH 6.5–8.5 (outside this range may cause abnormal results)
Incubation conditions (typical) Simultaneous addition of 1×Anti-MDCK:HRP and samples/standards; incubate on microplate thermoshaker at 600 rpm for 3 hours at room temperature; wash ×5; add TMB and incubate 15 minutes at RT; add stop solution and read
Readout Absorbance at 450 nm with reference at 620–650 nm; OD450–reference used for curve fitting
Reagent stability (opened) Anti‑MDCK HCP microtiter strips: store in bag with desiccant at 2–8 °C up to 60 days; reconstituted calibration standard: 2–8 °C up to 30 days

Features

  • One-step simultaneous detection: Detection antibody (HRP-conjugated) is added simultaneously with standards/samples to simplify workflow and reduce steps.
  • High sensitivity: LLOQ 2 ng/mL with a linear dynamic range up to 200 ng/mL using 4‑PL fitting.
  • MDCK-specific antibody coverage: Sheep polyclonal affinity-purified antibodies raised against MDCK HCPs provide broad coverage of host cell proteins from MDCK cells.
  • Ready-to-use coated strips: Microtiter strips pre-coated with capture antibody in sealed bag with desiccant for ease of use and storage.
  • Minimal cross-reactivity: Demonstrated no cross-reactivity with common non-MDCK host cells (E. coli, P. pastoris, Sf9).

Applications

  • Quantification of residual host cell proteins (HCPs) in products manufactured with MDCK host cells
  • Quality control testing of vaccines and influenza virus products produced in MDCK cells
  • In-process monitoring (harvested bulk, intermediates)
  • Testing of drug substance and drug product for MDCK-derived HCP contamination

Kit Contents

MDCK HCP Calibration Standard (lyophilized)Lyophilized; reconstitute with 500 μL Reconstitution Solution; reconstituted standard store 2–8 °C up to 30 days
Anti‑MDCK HCP Microtiter Strips (pre-coated)8 wells × 12 strips in sealed bag with desiccant; store at 2–8 °C; after opening store in bag with desiccant at 2–8 °C up to 60 days
Reconstitution Solution2 × 1.5 mL; room temperature equilibration before use
Diluent2 × 25 mL; store at 2–8 °C
Wash Buffer Concentrate (10×)2 × 25 mL; dilute 1:10 with ultrapure water before use; store at 2–8 °C
Anti‑MDCK:HRP (100×)1 × 120 μL HRP‑conjugated affinity‑purified sheep antibody; dilute 100× in Diluent before use; centrifuge before use; store at 2–8 °C
TMB Substrate1 × 12 mL; sealed, protect from light, equilibrate to RT before use; store at 2–8 °C
Stop Solution (1 M HCl)1 × 6 mL; corrosive—avoid contact with skin/eyes; store at 2–8 °C
Sealing Film3 pieces; room temperature storage
* Total: 96 tests/Kit | Method: ELISA (One-step double-antibody sandwich, HRP/TMB colorimetric)

Attention

• For Research Use Only (not for clinical diagnostic use).

• Equilibrate kit to room temperature for 20 minutes before use; return reagents to 2–8 °C after use.

• Use fresh 1×Wash Buffer and 1×Anti‑MDCK:HRP prepared immediately before use; prepare Anti‑MDCK:HRP by diluting 100× concentrate in Diluent and use immediately.

• Do not use Wash Buffer Concentrate or Diluent if cloudy or contains precipitates; heat to 37 °C to dissolve if necessary.

• Avoid repeated freeze-thaw cycles of samples; for long-term storage use ≤ -70 °C.

• Samples should be clear/transparent; remove particulates by centrifugation or filtration prior to assay.

• Maintain sample pH between 6.5 and 8.5 to avoid abnormal results.

• Do not mix reagents from different lot numbers.

• TMB Substrate should be colorless before use; discard if colored.

• Stop Solution is 1 M HCl — corrosive. Avoid contact with skin, eyes, and clothing.

• Avoid sodium azide (NaN3) in samples or buffers as it will inactivate HRP and lead to underestimated HCP levels.

• Read plate within 30 minutes after stopping reaction.

• Recommended minimum pipetting volume for accurate dilutions: 5 μL.

Quality Management & Certifications

Quality System

Download QMS

QMS (ISO, GMP)

Download Certificate

Quality Advantages

View Report

Quality Control Process

Download Process

📂 Technical Resources & Downloads

Frequently Asked Questions (FAQ)

Q1: Is this kit suitable for clinical diagnostic use?
No. This kit is for Research Use Only (RUO) and is not intended for clinical diagnostic use.
Q2: How do I reconstitute the calibration standard?
Add 500 μL of the provided Reconstitution Solution to the lyophilized MDCK HCP Calibration Standard, gently invert 3–5 times, let stand 5 minutes until clear. Use the reconstituted standard to prepare the ST1–ST8 dilution series as described in the manual.
Q3: What is the assay sensitivity and dynamic range?
The assay LLOQ is 2 ng/mL and the validated dynamic range is 2–200 ng/mL using a 4‑parameter logistic (4‑PL) calibration curve.
Q4: What precautions should I take for samples and reagents?
Ensure samples are free of particulates (centrifuge/filtrate), maintain pH 6.5–8.5, avoid sodium azide, minimize freeze-thaw cycles, prepare 1× reagents fresh, and follow recommended incubation and washing steps carefully.

Research Use Only

✔

Research Use Only (RUO); not for clinical diagnostic use – This product is intended for laboratory research purposes only and not for clinical or regulatory diagnostic use.

✔

Not intended for use in USDA or FDA regulated diagnostic testing or official compliance testing.

When can I expect my order to ship?

Most orders are filled and shipped within 2-3 business days from the time they are received.

Our standard shipping usually take 2-5 days.

We also provide express shippping for time-sensitive deliveries. 

Email contact@biofargo.com if you have any requirements.

 

Terms and Conditions