You have no items in your shopping cart.
For Research Use Only (RUO)
Product Description
The SHENTEK® Bovine Virus Analysis Multiplex Kit (BVDV/REO-3/PI-3/BPV-3/BAV-3) is a multiplex real-time PCR based qualitative assay serving as an analytical quality control reagent engineered exclusively for the simultaneous molecular evaluation of bioprocessing inputs, such as in vitro cell culture supplements and cell banks. Optimized for compatibility with the SHENTEK® Nucleic Acid Extraction Kit (Product No. 1506730), this assay ensures the efficient recovery and multiplexed analysis of target nucleic acids from complex industrial matrices.
Technical Specifications
| Parameter | Details |
|---|---|
| Limit of Detection (LOD) | 50 copies per reaction |
| Intended reactions | Reagents for 50 Reactions (kit provides sufficient reagents for 50 reactions) |
| Reaction volumes | RT-qPCR: 20 μL total (10 μL RT-qPCR MIX + 10 μL sample). qPCR (BPV-3/BAV-3): 30 μL total (20 μL qPCR MIX + 10 μL sample). |
| Thermal cycling (RT-qPCR for BVDV/REO-3/PI-3) | Reverse transcription 50 °C 15:00 (1 cycle); Activation 95 °C 00:30 (1 cycle); 40 cycles of Denaturation 95 °C 00:15 and Annealing/Extension 60 °C 01:00 (fluorescence read during annealing/extension). |
| Thermal cycling (qPCR for BPV-3/BAV-3) | Activation 95 °C 10:00 (1 cycle); 40 cycles of Denaturation 95 °C 00:15 and Annealing/Extension 60 °C 01:00 (fluorescence read during annealing/extension). |
| Reporter dyes / Targets | REO-3: FAM; PI-3: HEX; BVDV: CY5; BPV-3: FAM; BAV-3: CY5; Internal Control (IC): ROX. |
| Acceptance criteria — controls | NTC: Undetected (no specific amplification); NCS: Undetected; PCS: Ct < 35.00 with specific amplification; ROX (IC) for controls: Ct < 35.00. |
| Acceptance criteria — test samples | Positive call: specific amplification with Ct < 40.00 in the relevant fluorescence channel. Sample inhibition check: compare sample ROX Ct to NCS ROX Ct; difference > 2 indicates possible inhibition. If Ctsample - CtNCS < 2 then negative; ≥ 2 not conclusive (PCR inhibitors possible). |
| Instrument compatibility | SHENTEK-96S Real-time PCR System, LightCycler 480Ⅱ, ABI 7500 (other real-time PCR instruments may be used with appropriate setup). |
| Controls included / recommended | Internal Control (VIR IC) provided in kit; Positive Controls for individual targets sold separately (Product Nos. 1506736, 1506737, 1506738, 1506746, 1506739). |
Features
- Multiplex detection: Simultaneous detection of three RNA viruses (BVDV/REO-3/PI-3) or two DNA viruses (BPV-3/BAV-3) in a single well using multiplex real-time PCR.
- High sensitivity: Limit of detection down to 50 copies per reaction.
- Internal control provided: VIR Internal Control (IC) included to monitor extraction and amplification performance and identify inhibition.
- Compatible with standard instruments: Validated on SHENTEK-96S, LightCycler 480Ⅱ and ABI 7500; adaptable to other real-time PCR platforms.
- Optimized workflow for complex matrices: Designed to work with SHENTEK® Virus DNA & RNA Extraction Kit for efficient recovery from serum and cell matrices.
Applications
- Qualitative molecular analysis of BVDV/REO-3/PI-3/BPV-3/BAV-3 target sequences in industrial cell banks
- Analytical quality control of biological seed lots
- Molecular evaluation of in vitro cell culture supplements for BVDV/REO-3/PI-3/BPV-3/BAV-3 nucleic acids
- In-process monitoring and lot-release analysis for biological manufacturing
- In vitro research projects assessing nucleic acids target sequences in complex culture matrices
Kit Contents
Attention
• For Research Use Only (RUO). Not for diagnostic or clinical use.
• Read Material Safety Data Sheets (MSDS) and follow handling instructions.
• Wear appropriate PPE: protective eyewear, mask, lab coat and gloves.
• Handle positive controls and extraction procedures in a biological safety cabinet following BSL-2 guidelines.
• Use nuclease-free consumables and reagents certified RNase/DNase-free.
• Thaw kit components completely at 2–8 °C or on ice, vortex thoroughly and centrifuge briefly before use.
• Protect probe-containing reagents from light.
• Check control acceptance criteria (NTC/NCS/PCS/IC Ct thresholds) for run validity.
• If ROX (IC) Ct(sample) - ROX Ct(NCS) > 2, investigate potential PCR inhibition and repeat extraction/dilution as needed.
Quality Management & Certifications
Quality System
Download QMSQMS (ISO, GMP)
Download CertificateQuality Advantages
View ReportQuality Control Process
Download ProcessTechnical Resources & Downloads
Frequently Asked Questions (FAQ)
Research Use Only
Research Use Only (RUO) – This product is intended for laboratory research purposes only and not for clinical or regulatory diagnostic use.
Not intended for use in USDA or FDA regulated diagnostic testing or official compliance testing.
When can I expect my order to ship?
Most orders are filled and shipped within 2-3 business days from the time they are received.
Our standard shipping usually take 2-5 days.
We also provide express shippping for time-sensitive deliveries.
Email contact@biofargo.com if you have any requirements.

