{"product_id":"uniqo-160-fully-automated-ifa-system-from-sample-processing-to-image-acquisition","title":"UNIQO 160 Fully Automated IFA System – from Sample Processing to Image Acquisition","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eUNIQO 160\u003c\/strong\u003e provides a complete automation solution from primary sample pipetting to automated IFA image acquisition within a single instrument.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eIn one run, this benchtop device processes up to 160 primary samples and 18 microscope slides. Samples, reagents, and slides are automatically identified and assigned via barcodes for complete traceability. Slides are protected from drying through automated mounting and cover-slipping after incubation.\u003c\/p\u003e\n            \u003cp\u003eThis device integrates a high-quality microscope with automatically changing objectives (4x, 10x, 20x) for fluorescence image acquisition across the entire worklist.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eOperation\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eFull HD touch-screen monitor, 15 inches\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommunication with LIS\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eCompatible\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eElectrical Data\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100–240 V AC\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions \/ Weight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1200 mm (47 in) × 900 mm (35 in) × 700 mm (27.5 in) (W × D × H, without accessories)\u003cbr\u003eApprox. 150 kg (330 lbs)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Three-Needle System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eEfficient pipetting of samples and reagents as well as washing of slides.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh Capacity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses 160 IFA samples, 288 dilutions, and 18 slides per run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFull Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eBarcode scanners enable identification of samples, reagents, and slides.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Loading\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports up to 20 controls, 4 dilution buffers, and 9 bottles of conjugate and mounting medium.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated Imaging\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eFluorescence image recording with autofocus and automatically changing objectives (4x, 10x, 20x).\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eIFA Processing:\u003c\/strong\u003e Automated processing of indirect immunofluorescence assays from sample pipetting to image acquisition.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eHigh-Throughput Laboratories:\u003c\/strong\u003e Suitable for clinical and research laboratories requiring standardized IFA workflows.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Diagnostics:\u003c\/strong\u003e Detection of ANA, ANCA, and related markers using fluorescence-based methods.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e Immunofluorescence slide-based antibody testing.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eCentralized Laboratories:\u003c\/strong\u003e End-to-end automation with minimal manual intervention and reduced human error.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eTraceability \u0026amp; Data Integrity:\u003c\/strong\u003e Barcode-based tracking of samples and reagents.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eDigital Microscopy:\u003c\/strong\u003e Automated image capture, analysis, and reporting integration (LIS compatibility).\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375798350005,"sku":"EU-ANA-U160","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/UNIQO_160_Fully_Automated_IFA_System_from_Sample_Processing_to_Image_Acquisition.jpg?v=1774236167","url":"https:\/\/biofargo.com\/products\/uniqo-160-fully-automated-ifa-system-from-sample-processing-to-image-acquisition","provider":"Biofargo","version":"1.0","type":"link"}