{"product_id":"slan®-96s-96-well-real-time-pcr-system","title":"SLAN®-96S 96-Well Real-Time PCR System","description":"\u003csection\u003e\n  \u003ch2\u003eDescription\u003c\/h2\u003e\n  \u003cp\u003eLaboratories processing multiple real-time PCR reactions need sufficient sample capacity, compatibility with common PCR consumables, stable temperature control, and flexible fluorescence detection. The SLAN®-96S is a 96-well real-time PCR system designed for experiments using 0.2 mL PCR tubes, 8-tube strips, or 96-well PCR plates. It supports reaction volumes from 15 to 100 µL.\u003c\/p\u003e\n\n  \u003cp\u003eFor multiplex real-time PCR workflows, the SLAN®-96S provides four standard fluorescence channels and supports two additional optional channels. The six-channel qPCR system configuration enables six-target fluorescence detection without cross-interference correction. Compatible probes and dyes include FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425.\u003c\/p\u003e\n\n  \u003cp\u003eThe thermal system provides a temperature control range of 4–99°C, a maximum heating and cooling rate of 4.0°C\/s, temperature uniformity of ±0.1°C, and temperature accuracy of ±0.1°C. The optical system uses a maintenance-free LED excitation source and a high-sensitivity photoelectric detector.\u003c\/p\u003e\n\n  \u003cp\u003eThe SLAN®-96S also functions as an HRM real-time PCR system. Its software supports qualitative analysis, absolute quantification, relative quantification, standard melting curves, endpoint allele genotyping, melting-curve genotyping, high-resolution melting analysis, and isothermal amplification. Experimental data can be exported in XLSX, CSV, and TXT formats.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eSpecification\u003c\/h2\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:720px; border-collapse:collapse;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n          \u003ctd\u003eSLAN®-96S Real-Time PCR System\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n          \u003ctd\u003eSLAN®-96S\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eSample Capacity\u003c\/th\u003e\n          \u003ctd\u003e96 wells\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eReaction Volume\u003c\/th\u003e\n          \u003ctd\u003e15–100 µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eCompatible Consumables\u003c\/th\u003e\n          \u003ctd\u003e0.2 mL PCR tubes, 8-tube strips, and 96-well PCR plates\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDetection Sensitivity\u003c\/th\u003e\n          \u003ctd\u003eMinimum resolution of 1 copy\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eLinear Range\u003c\/th\u003e\n          \u003ctd\u003e10\u003csup\u003e0\u003c\/sup\u003e–10\u003csup\u003e10\u003c\/sup\u003e copies\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n          \u003ctd\u003eCV \u0026lt;1.00%\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eSample Linearity\u003c\/th\u003e\n          \u003ctd\u003e|r| ≥0.9990\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eInternal Reference Dye Correction\u003c\/th\u003e\n          \u003ctd\u003eNot required\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMultiplex Fluorescence Detection\u003c\/th\u003e\n          \u003ctd\u003eUp to six-target detection without cross-interference correction\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eHRM Analysis\u003c\/th\u003e\n          \u003ctd\u003eSupported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Control Method\u003c\/th\u003e\n          \u003ctd\u003eSemiconductor method\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Control Modes\u003c\/th\u003e\n          \u003ctd\u003eBlock control and tube control\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Range\u003c\/th\u003e\n          \u003ctd\u003e4–99°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMaximum Heating and Cooling Rate\u003c\/th\u003e\n          \u003ctd\u003e4.0°C\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Uniformity\u003c\/th\u003e\n          \u003ctd\u003e±0.1°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n          \u003ctd\u003e±0.1°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eHeated Lid\u003c\/th\u003e\n          \u003ctd\u003eAutomatic heated lid\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eExcitation Source\u003c\/th\u003e\n          \u003ctd\u003eMaintenance-free LED\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDetector\u003c\/th\u003e\n          \u003ctd\u003eHigh-sensitivity photoelectric sensor\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eData Export Formats\u003c\/th\u003e\n          \u003ctd\u003eXLSX, CSV, and TXT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eCustom Reports\u003c\/th\u003e\n          \u003ctd\u003eSupported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eOperating System\u003c\/th\u003e\n          \u003ctd\u003eMicrosoft Windows XP, Vista, 7, and 8\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMinimum Computer Memory\u003c\/th\u003e\n          \u003ctd\u003e4 GB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMinimum Hard Drive Capacity\u003c\/th\u003e\n          \u003ctd\u003e40 GB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003ePower Input\u003c\/th\u003e\n          \u003ctd\u003e220 VAC, 50 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMaximum Power\u003c\/th\u003e\n          \u003ctd\u003e850 VA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n          \u003ctd\u003eRS232 and USB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n          \u003ctd\u003e386 × 534 × 258 mm (W × D × H)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n          \u003ctd\u003e18 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFluorescence Channels\u003c\/h2\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:760px; border-collapse:collapse;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"col\"\u003eChannel\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eCompatible Probes and Dyes\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eExcitation Wavelength\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eDetection Wavelength\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eConfiguration\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 1\u003c\/td\u003e\n          \u003ctd\u003eFAM \/ SYBR Green\u003c\/td\u003e\n          \u003ctd\u003e470 nm\u003c\/td\u003e\n          \u003ctd\u003e510 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 2\u003c\/td\u003e\n          \u003ctd\u003eVIC \/ HEX \/ JOE \/ TET \/ TAMRA \/ Cy3\u003c\/td\u003e\n          \u003ctd\u003e530 nm\u003c\/td\u003e\n          \u003ctd\u003e565 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 3\u003c\/td\u003e\n          \u003ctd\u003eROX \/ Texas Red\u003c\/td\u003e\n          \u003ctd\u003e585 nm\u003c\/td\u003e\n          \u003ctd\u003e620 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 4\u003c\/td\u003e\n          \u003ctd\u003eCY5\u003c\/td\u003e\n          \u003ctd\u003e630 nm\u003c\/td\u003e\n          \u003ctd\u003e665 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 5\u003c\/td\u003e\n          \u003ctd\u003eQuasar 705\u003c\/td\u003e\n          \u003ctd\u003e690 nm\u003c\/td\u003e\n          \u003ctd\u003e705 nm\u003c\/td\u003e\n          \u003ctd\u003eOptional\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 6\u003c\/td\u003e\n          \u003ctd\u003eAtto 425\u003c\/td\u003e\n          \u003ctd\u003e420 nm\u003c\/td\u003e\n          \u003ctd\u003e470 nm\u003c\/td\u003e\n          \u003ctd\u003eOptional\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFeatures\u003c\/h2\u003e\n\n  \u003ch3\u003e96-Well Reaction Capacity\u003c\/h3\u003e\n  \u003cp\u003eThe SLAN®-96S provides a 96-well reaction platform for real-time fluorescence PCR analysis.\u003c\/p\u003e\n\n  \u003ch3\u003eFlexible PCR Consumable Compatibility\u003c\/h3\u003e\n  \u003cp\u003eThe 96-well qPCR instrument accepts 0.2 mL PCR tubes, 8-tube strips, and 96-well PCR plates. The supported reaction volume is 15–100 µL.\u003c\/p\u003e\n\n  \u003ch3\u003eUp to Six Fluorescence Channels\u003c\/h3\u003e\n  \u003cp\u003eFour fluorescence channels are provided as standard. Channels 5 and 6 are optional, enabling up to six-channel fluorescence detection.\u003c\/p\u003e\n\n  \u003ch3\u003eSix-Target Multiplex Detection\u003c\/h3\u003e\n  \u003cp\u003eThe system supports six-target fluorescence detection without cross-interference correction when configured with six fluorescence channels.\u003c\/p\u003e\n\n  \u003ch3\u003eHigh-Resolution Melting Analysis\u003c\/h3\u003e\n  \u003cp\u003eThe SLAN®-96S supports high-resolution melting curve analysis as part of its software analysis functions.\u003c\/p\u003e\n\n  \u003ch3\u003ePrecise Thermal Performance\u003c\/h3\u003e\n  \u003cp\u003eThe system provides a 4–99°C temperature range, a maximum heating and cooling rate of 4.0°C\/s, temperature uniformity of ±0.1°C, and temperature accuracy of ±0.1°C.\u003c\/p\u003e\n\n  \u003ch3\u003eMaintenance-Free LED Excitation\u003c\/h3\u003e\n  \u003cp\u003eThe optical system uses a maintenance-free LED excitation source and a high-sensitivity photoelectric sensor.\u003c\/p\u003e\n\n  \u003ch3\u003eNo Internal Reference Dye Correction\u003c\/h3\u003e\n  \u003cp\u003eThe manufacturer states that internal reference dye correction is not required.\u003c\/p\u003e\n\n  \u003ch3\u003eMultiple Analysis Modes\u003c\/h3\u003e\n  \u003cp\u003eThe software supports qualitative analysis, absolute quantification, relative quantification, standard melting curves, endpoint allele genotyping, melting-curve genotyping, HRM analysis, and isothermal amplification.\u003c\/p\u003e\n\n  \u003ch3\u003eData Export and Reporting\u003c\/h3\u003e\n  \u003cp\u003eExperimental data can be exported in XLSX, CSV, and TXT formats. Custom reports are supported.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eApplication\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eQualitative real-time PCR analysis\u003c\/li\u003e\n    \u003cli\u003eAbsolute quantitative PCR analysis\u003c\/li\u003e\n    \u003cli\u003eRelative quantitative PCR analysis\u003c\/li\u003e\n    \u003cli\u003eStandard melting curve analysis\u003c\/li\u003e\n    \u003cli\u003eEndpoint allele genotyping\u003c\/li\u003e\n    \u003cli\u003eMelting-curve genotyping\u003c\/li\u003e\n    \u003cli\u003eHigh-resolution melting curve analysis\u003c\/li\u003e\n    \u003cli\u003eIsothermal amplification\u003c\/li\u003e\n    \u003cli\u003eMulticolor fluorescence detection\u003c\/li\u003e\n    \u003cli\u003eMultiplex real-time PCR analysis\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFAQ\u003c\/h2\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the sample capacity of the SLAN®-96S real-time PCR system?\u003c\/summary\u003e\n    \u003cp\u003eThe SLAN®-96S has a sample capacity of 96 wells.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat reaction volume does the SLAN®-96S support?\u003c\/summary\u003e\n    \u003cp\u003eThe supported reaction volume is 15–100 µL.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich PCR consumables are compatible with the SLAN®-96S?\u003c\/summary\u003e\n    \u003cp\u003eThe system is compatible with 0.2 mL PCR tubes, 8-tube strips, and 96-well PCR plates.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eHow many fluorescence channels does the SLAN®-96S support?\u003c\/summary\u003e\n    \u003cp\u003eThe system includes four standard fluorescence channels. Channel 5 for Quasar 705 and Channel 6 for Atto 425 are optional.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich fluorescent probes and dyes are supported?\u003c\/summary\u003e\n    \u003cp\u003eThe listed probes and dyes are FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425. Quasar 705 and Atto 425 require the optional fifth and sixth channels.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eDoes the SLAN®-96S support multiplex real-time PCR?\u003c\/summary\u003e\n    \u003cp\u003eYes. The system supports up to six-target fluorescence detection without cross-interference correction when configured with six channels.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eDoes the SLAN®-96S support HRM analysis?\u003c\/summary\u003e\n    \u003cp\u003eYes. High-resolution melting curve analysis is included among the listed software analysis functions.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eDoes the SLAN®-96S require internal reference dye correction?\u003c\/summary\u003e\n    \u003cp\u003eNo. The manufacturer states that internal reference dye correction is not required.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the detection sensitivity of the SLAN®-96S?\u003c\/summary\u003e\n    \u003cp\u003eThe stated minimum resolution is 1 copy. The stated linear range is 10\u003csup\u003e0\u003c\/sup\u003e–10\u003csup\u003e10\u003c\/sup\u003e copies, repeatability is CV \u0026lt;1.00%, and sample linearity is |r| ≥0.9990.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat are the temperature performance specifications?\u003c\/summary\u003e\n    \u003cp\u003eThe temperature range is 4–99°C. The maximum heating and cooling rate is 4.0°C\/s, temperature uniformity is ±0.1°C, and temperature accuracy is ±0.1°C.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich analysis functions are available?\u003c\/summary\u003e\n    \u003cp\u003eThe software supports qualitative analysis, absolute quantification, relative quantification, standard melting curves, endpoint allele genotyping, melting-curve genotyping, HRM analysis, and isothermal amplification.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich data export formats are supported?\u003c\/summary\u003e\n    \u003cp\u003eExperimental data can be exported in XLSX, CSV, and TXT formats. Custom reports are also supported.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/section\u003e","brand":"Hongshi","offers":[{"title":"Default Title","offer_id":53194253533365,"sku":"SLAN-96S","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/slan-96s-96-well-real-time-pcr-system.jpg?v=1788246136","url":"https:\/\/biofargo.com\/products\/slan%c2%ae-96s-96-well-real-time-pcr-system","provider":"Biofargo","version":"1.0","type":"link"}