{"product_id":"slan®-96p-96-well-real-time-pcr-system","title":"SLAN®-96P 96-Well Real-Time PCR System","description":"\u003csection\u003e\n  \u003ch2\u003eDescription\u003c\/h2\u003e\n  \u003cp\u003eLaboratories may need to run different real-time PCR programs without waiting for one full 96-well experiment to finish. The SLAN®-96P 96-well real-time PCR system addresses this workflow requirement with two independent 48-well reaction modules. Users can run two separate 48-well experiments with different amplification programs or operate the system as one 96-well experiment.\u003c\/p\u003e\n  \u003cp\u003eThis dual-block real-time PCR system combines a 2 × 48-well format with a sample volume of 15–100 µL and compatibility with 0.2 mL PCR tubes. Its temperature control system provides a 4–99°C operating range, a maximum heating and cooling rate of 4.0°C\/s, temperature uniformity of ±0.1°C, and temperature accuracy of ±0.1°C.\u003c\/p\u003e\n  \u003cp\u003eFor laboratories performing multiplex real-time PCR, the SLAN®-96P supports four standard fluorescence channels and up to six channels with optional configurations. Compatible probes and dyes include FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425. The system supports six-target fluorescence detection without cross-interference correction and does not require internal reference dye correction.\u003c\/p\u003e\n  \u003cp\u003eThe SLAN®-96P also supports high-resolution melting analysis. Its software covers qualitative analysis, absolute quantification, standard melting curves, endpoint allele identification, melting-curve genotyping, and high-resolution melting curves. Experimental data can be exported in XLSX, CSV, and TXT formats.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eSpecification\u003c\/h2\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:720px; border-collapse:collapse;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eProduct Name\u003c\/th\u003e\n          \u003ctd\u003eSLAN®-96P Real-Time PCR System\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n          \u003ctd\u003eSLAN®-96P\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eSample Capacity\u003c\/th\u003e\n          \u003ctd\u003e96 wells, configured as two 48-well reaction modules\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eReaction Modes\u003c\/th\u003e\n          \u003ctd\u003eTwo independent 48-well experiments or one 96-well experiment\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eSample Volume\u003c\/th\u003e\n          \u003ctd\u003e15–100 µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eCompatible Consumables\u003c\/th\u003e\n          \u003ctd\u003e0.2 mL PCR tubes\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDetection Sensitivity\u003c\/th\u003e\n          \u003ctd\u003eMinimum resolution of 1 copy\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eLinear Range\u003c\/th\u003e\n          \u003ctd\u003e10\u003csup\u003e0\u003c\/sup\u003e–10\u003csup\u003e10\u003c\/sup\u003e copies\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eRepeatability\u003c\/th\u003e\n          \u003ctd\u003eCV \u0026lt;1.00%\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eSample Linearity\u003c\/th\u003e\n          \u003ctd\u003e|r| ≥0.9990\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eInternal Reference Dye Correction\u003c\/th\u003e\n          \u003ctd\u003eNot required\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eFluorescence Detection\u003c\/th\u003e\n          \u003ctd\u003eUp to six-target detection without cross-interference correction\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eHRM Analysis\u003c\/th\u003e\n          \u003ctd\u003eSupported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eReaction Module Type\u003c\/th\u003e\n          \u003ctd\u003eDual-slot, dual-module design\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Control Method\u003c\/th\u003e\n          \u003ctd\u003eSemiconductor thermoelectric module\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Control Modes\u003c\/th\u003e\n          \u003ctd\u003eBlock control and tube control\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Range\u003c\/th\u003e\n          \u003ctd\u003e4–99°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMaximum Heating and Cooling Rate\u003c\/th\u003e\n          \u003ctd\u003e4.0°C\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Uniformity\u003c\/th\u003e\n          \u003ctd\u003e±0.1°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eTemperature Accuracy\u003c\/th\u003e\n          \u003ctd\u003e±0.1°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eHeated Lid\u003c\/th\u003e\n          \u003ctd\u003eAutomatic heated lid\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eExcitation Source\u003c\/th\u003e\n          \u003ctd\u003eMaintenance-free LED\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDetector\u003c\/th\u003e\n          \u003ctd\u003eHigh-sensitivity photoelectric sensor\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eData Export Formats\u003c\/th\u003e\n          \u003ctd\u003eXLSX, CSV, and TXT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eCustom Reports\u003c\/th\u003e\n          \u003ctd\u003eSupported\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eOperating System\u003c\/th\u003e\n          \u003ctd\u003eMicrosoft Windows XP, Vista, 7, 8, 10, 11, and later versions\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMinimum Computer Memory\u003c\/th\u003e\n          \u003ctd\u003e4 GB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMinimum Hard Drive Capacity\u003c\/th\u003e\n          \u003ctd\u003e40 GB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003ePower Input\u003c\/th\u003e\n          \u003ctd\u003e220 VAC, 50 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eMaximum Power\u003c\/th\u003e\n          \u003ctd\u003e850 VA\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eInterfaces\u003c\/th\u003e\n          \u003ctd\u003eRS232 and USB\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eDimensions\u003c\/th\u003e\n          \u003ctd\u003e386 × 520 × 250 mm (W × D × H)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n          \u003ctd\u003e18 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n          \u003ctd\u003e18-month free warranty\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFluorescence Channels\u003c\/h2\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:760px; border-collapse:collapse;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth scope=\"col\"\u003eChannel\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eCompatible Probes and Dyes\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eExcitation Wavelength\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eDetection Wavelength\u003c\/th\u003e\n          \u003cth scope=\"col\"\u003eConfiguration\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 1\u003c\/td\u003e\n          \u003ctd\u003eFAM \/ SYBR Green\u003c\/td\u003e\n          \u003ctd\u003e470 nm\u003c\/td\u003e\n          \u003ctd\u003e510 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 2\u003c\/td\u003e\n          \u003ctd\u003eVIC \/ HEX \/ JOE \/ TET \/ TAMRA \/ Cy3\u003c\/td\u003e\n          \u003ctd\u003e530 nm\u003c\/td\u003e\n          \u003ctd\u003e565 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 3\u003c\/td\u003e\n          \u003ctd\u003eROX \/ Texas Red\u003c\/td\u003e\n          \u003ctd\u003e585 nm\u003c\/td\u003e\n          \u003ctd\u003e620 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 4\u003c\/td\u003e\n          \u003ctd\u003eCY5\u003c\/td\u003e\n          \u003ctd\u003e630 nm\u003c\/td\u003e\n          \u003ctd\u003e665 nm\u003c\/td\u003e\n          \u003ctd\u003eStandard\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 5\u003c\/td\u003e\n          \u003ctd\u003eQuasar 705\u003c\/td\u003e\n          \u003ctd\u003e690 nm\u003c\/td\u003e\n          \u003ctd\u003e705 nm\u003c\/td\u003e\n          \u003ctd\u003eOptional\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003ctd\u003eChannel 6\u003c\/td\u003e\n          \u003ctd\u003eAtto 425\u003c\/td\u003e\n          \u003ctd\u003e420 nm\u003c\/td\u003e\n          \u003ctd\u003e470 nm\u003c\/td\u003e\n          \u003ctd\u003eOptional\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFeatures\u003c\/h2\u003e\n\n  \u003ch3\u003eIndependent 2 × 48-Well Operation\u003c\/h3\u003e\n  \u003cp\u003eThe SLAN®-96P has two independent 48-well reaction modules. Laboratories can run two experiments with different amplification programs or use the system for one 96-well experiment.\u003c\/p\u003e\n\n  \u003ch3\u003ePrecise Temperature Control\u003c\/h3\u003e\n  \u003cp\u003ePoint-by-point temperature compensation provides ±0.1°C well-to-well temperature uniformity. The system also provides ±0.1°C temperature accuracy and a maximum heating and cooling rate of 4.0°C\/s.\u003c\/p\u003e\n\n  \u003ch3\u003eMaintenance-Free Fluorescence Detection\u003c\/h3\u003e\n  \u003cp\u003eThe optical system uses a high-power, maintenance-free LED excitation source and a high-sensitivity photoelectric detector. Fluorescence is collected from the side of the reaction tube.\u003c\/p\u003e\n\n  \u003ch3\u003eNo Internal Reference Dye Correction\u003c\/h3\u003e\n  \u003cp\u003eThe optical design provides consistent fluorescence detection across sample wells without an edge effect. Internal reference dye correction is not required.\u003c\/p\u003e\n\n  \u003ch3\u003eUp to Six Fluorescence Channels\u003c\/h3\u003e\n  \u003cp\u003eThe 96-well qPCR instrument supports four standard fluorescence channels. Channels 5 and 6 are optional, allowing the system to be configured for up to six-channel multiplex real-time PCR detection.\u003c\/p\u003e\n\n  \u003ch3\u003eAutomatic Gain Selection\u003c\/h3\u003e\n  \u003cp\u003eThe system automatically selects the optimal gain according to the measured fluorescence value, without requiring manual gain adjustment.\u003c\/p\u003e\n\n  \u003ch3\u003eHigh-Resolution Melting Support\u003c\/h3\u003e\n  \u003cp\u003eThe SLAN®-96P combines its optical and temperature performance with software analysis algorithms for high-resolution melting curve analysis. Both step and continuous scanning modes are supported.\u003c\/p\u003e\n\n  \u003ch3\u003eOpen Reagent and Consumables Platform\u003c\/h3\u003e\n  \u003cp\u003eThe system uses an open reagent and consumables platform and is compatible with 0.2 mL PCR tubes.\u003c\/p\u003e\n\n  \u003ch3\u003eFlexible Data Management\u003c\/h3\u003e\n  \u003cp\u003eThe software can import patient and plate information from LIMS or a sample-preparation system. It also supports custom data export formats, custom report templates, and XLSX, CSV, and TXT data export.\u003c\/p\u003e\n\n  \u003ch3\u003eMulti-Instrument Control\u003c\/h3\u003e\n  \u003cp\u003eThe software can control multiple SLAN-48P, SLAN-96S, and SLAN-96P instruments at the same time.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eApplication\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eQualitative real-time PCR analysis\u003c\/li\u003e\n    \u003cli\u003eAbsolute quantitative PCR analysis\u003c\/li\u003e\n    \u003cli\u003eStandard melting curve analysis\u003c\/li\u003e\n    \u003cli\u003eEndpoint allele identification\u003c\/li\u003e\n    \u003cli\u003eMelting-curve genotyping\u003c\/li\u003e\n    \u003cli\u003eHigh-resolution melting curve analysis\u003c\/li\u003e\n    \u003cli\u003eMulticolor fluorescence detection\u003c\/li\u003e\n    \u003cli\u003eMulti-gene testing using multi-tube settings\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFAQ\u003c\/h2\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the sample capacity of the SLAN®-96P real-time PCR system?\u003c\/summary\u003e\n    \u003cp\u003eThe SLAN®-96P has a total capacity of 96 wells. Its reaction area consists of two 48-well modules.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eCan the two 48-well reaction modules run independently?\u003c\/summary\u003e\n    \u003cp\u003eYes. The two modules can independently run experiments with different amplification programs. They can also be used together for one 96-well experiment.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat reaction volume does the SLAN®-96P support?\u003c\/summary\u003e\n    \u003cp\u003eThe supported sample volume is 15–100 µL.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich PCR consumables are compatible with this 96-well qPCR instrument?\u003c\/summary\u003e\n    \u003cp\u003eThe system is compatible with 0.2 mL PCR tubes.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eHow many fluorescence channels does the SLAN®-96P support?\u003c\/summary\u003e\n    \u003cp\u003eThe system has four standard fluorescence channels. Channel 5 for Quasar 705 and channel 6 for Atto 425 are optional.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich fluorescent probes and dyes are supported?\u003c\/summary\u003e\n    \u003cp\u003eThe listed probes and dyes are FAM, SYBR Green, VIC, HEX, JOE, TET, TAMRA, Cy3, ROX, Texas Red, CY5, Quasar 705, and Atto 425. Quasar 705 and Atto 425 require the optional fifth and sixth channels.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eDoes the SLAN®-96P support multiplex real-time PCR?\u003c\/summary\u003e\n    \u003cp\u003eYes. The system supports up to six-target fluorescence detection without cross-interference correction when configured with six detection channels.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eDoes this real-time PCR system support HRM analysis?\u003c\/summary\u003e\n    \u003cp\u003eYes. The SLAN®-96P supports high-resolution melting curve analysis, including step and continuous scanning modes.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eIs ROX or another internal reference dye correction required?\u003c\/summary\u003e\n    \u003cp\u003eNo. The manufacturer states that internal reference dye correction is not required.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat are the temperature performance specifications?\u003c\/summary\u003e\n    \u003cp\u003eThe temperature range is 4–99°C. The maximum heating and cooling rate is 4.0°C\/s, temperature uniformity is ±0.1°C, and temperature accuracy is ±0.1°C.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the detection sensitivity of the SLAN®-96P?\u003c\/summary\u003e\n    \u003cp\u003eThe stated minimum resolution is 1 copy. The stated linear range is 10\u003csup\u003e0\u003c\/sup\u003e–10\u003csup\u003e10\u003c\/sup\u003e copies, with repeatability of CV \u0026lt;1.00% and sample linearity of |r| ≥0.9990.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich analysis functions are included in the software?\u003c\/summary\u003e\n    \u003cp\u003eThe software supports qualitative analysis, absolute quantification, standard melting curves, endpoint allele identification, melting-curve genotyping, and high-resolution melting curve analysis.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhich data export formats are supported?\u003c\/summary\u003e\n    \u003cp\u003eExperimental data can be exported in XLSX, CSV, and TXT formats. Custom reports are also supported.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eCan the SLAN®-96P connect with a LIMS?\u003c\/summary\u003e\n    \u003cp\u003eThe software can import patient and plate information from a LIMS or sample-preparation system.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003eWhat is the warranty period for the SLAN®-96P?\u003c\/summary\u003e\n    \u003cp\u003eThe stated free warranty period is 18 months.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/section\u003e","brand":"Hongshi","offers":[{"title":"Default Title","offer_id":53194209198261,"sku":"SLAN-96P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/slan-96p-96-well-real-time-pcr-system.jpg?v=1788244685","url":"https:\/\/biofargo.com\/products\/slan%c2%ae-96p-96-well-real-time-pcr-system","provider":"Biofargo","version":"1.0","type":"link"}