{"product_id":"s96-96-well-fluorometer-fs-m2005-starlighter","title":"S96 96-Well Fluorometer FS-M2005——StarLighter","description":"\u003csection\u003e\n  \u003ch2\u003eDescription\u003c\/h2\u003e\n  \u003cp\u003eLaboratories processing multiple DNA, RNA, microRNA, or protein samples may need to repeat individual measurements when using a single-sample instrument. The StarLighter Fluorometer S96 FS-M2005 provides a 96-well fluorescence measurement format for quantitative analysis of up to 96 sample positions. This high-throughput nucleic acid quantification fluorometer requires only 1–20 µL of sample and completes a whole-plate measurement in 55 seconds.\u003c\/p\u003e\n  \u003cp\u003eThe FS-M2005 operates as a two-channel, top-reading fluorescence microplate reader. It uses LED excitation and an SiPMT detector to measure dsDNA, ssDNA, RNA, microRNA, and protein assays. Blue excitation is provided at 457–483 nm with green emission detection at 520–540 nm, while red excitation is provided at 622–638 nm with red emission detection at 672–712 nm.\u003c\/p\u003e\n  \u003cp\u003eThe instrument uses a 0.3 mL 96-well flat-bottom black ELISA plate measuring 128 × 86 × 15 mm. Sample volume can be set between 1 and 20 µL, and the combined sample and working-solution volume must be 200 µL per well. Experiment protocols, well positions, standards, blanks, sample information, and measurement results are managed through the supplied PC software. Results can be saved and exported in Excel format.\u003c\/p\u003e\n  \u003cp\u003eThis 96-well fluorometer is for research use only and is not intended for diagnostic or therapeutic procedures.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eSpecification\u003c\/h2\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:680px; border-collapse:collapse;\"\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eProduct Name\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter Fluorometer S96\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eProduct Model\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-M2005\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eInstrument Type\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e96-well fluorometer\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSample Throughput\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e96 positions\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSample Volume\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1–20 µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eTotal Reaction Volume\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e200 µL per well\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eCompatible Plate\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e0.3 mL 96-well flat-bottom black ELISA plate\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eCompatible Plate Dimensions\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e128 × 86 × 15 mm; consumable height must not exceed 15 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eWhole-Plate Test Time\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e55 seconds\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eLight Source\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eLED\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eFluorescence Channels\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eExcitation Wavelengths\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBlue: 457–483 nm; Red: 622–638 nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eEmission Wavelengths\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eGreen: 520–540 nm; Red: 672–712 nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDetector\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eSiPMT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDetection Method\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eTop detection\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSupported Sample Types\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003edsDNA, ssDNA, RNA, microRNA, and proteins\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSensitivity\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003edsDNA: 0.05 ng\/µL; ssDNA: 0.1 ng\/µL; RNA: 0.5 ng\/µL; microRNA: 0.1 ng\/µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDNA HS Detection Range\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e0.01–100 ng\/µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDNA BR Detection Range\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1–1000 ng\/µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eRNA Detection Range\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e0.25–100 ng\/µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eRNA BR Detection Range\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1–1000 ng\/µL\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eCalibration\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e2-point calibration\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDynamic Range\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e5 orders of magnitude\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eCommunication Interface\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBluetooth and serial port\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSoftware Languages\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eChinese and English\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eSoftware Temperature Setting\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eAmbient temperature to 37°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003ePower\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eDC 24 V, 2.5 A; 60 W maximum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eOperating Environment\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e15–30°C; less than 75% RH; indoor use only\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eTransport and Storage Temperature\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e−20–60°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eOperating Altitude\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eUp to 2,000 m above sea level\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eDimensions\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e274 × 180 × 106 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eWeight\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e2.7 kg\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eIntended Use\u003c\/th\u003e\n          \u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFor research use only\u003c\/td\u003e\n        \u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFeatures\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e96-well sample throughput:\u003c\/strong\u003e The instrument provides 96 sample positions for high-throughput fluorescence measurement.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLow sample-volume requirement:\u003c\/strong\u003e Each measurement uses 1–20 µL of sample.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e55-second whole-plate reading:\u003c\/strong\u003e A complete plate can be measured in 55 seconds.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eTwo fluorescence channels:\u003c\/strong\u003e The optical system provides blue and red excitation channels with green and red emission detection.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMultiple supported analytes:\u003c\/strong\u003e Test items include dsDNA, ssDNA, RNA, microRNA, proteins, oligo, blue-light scanning, and red-light scanning.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSiPMT top-reading detection:\u003c\/strong\u003e Fluorescence is measured from the top of the 96-well plate using an SiPMT detector.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexible well configuration:\u003c\/strong\u003e The software supports SAMPLE, STANDARD, BLANK, and RFU well types.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtocol management:\u003c\/strong\u003e Users can create, save, and delete experimental protocols and modify sample information and well positions.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eResult management:\u003c\/strong\u003e Experimental data can be imported, saved, deleted, annotated, and exported in Excel format.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eChinese and English software:\u003c\/strong\u003e The PC software interface supports Chinese and English language selection.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003ePackage Contents\u003c\/h3\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:620px; border-collapse:collapse;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eItem\u003c\/th\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eQuantity\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFluorescence Reader\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 unit\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003ePower cord\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eUSB flash drive containing the user manual, communication protocol, and software installation package\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003ePacking list\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eUSB cable\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003ePower adapter\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBlack ELISA plate\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\n  \u003ch3\u003eRecommended Assay Kits\u003c\/h3\u003e\n  \u003cp\u003eThe user guide lists the following StarLighter and Thermo Fisher assay kits for use with the 96-well fluorometer.\u003c\/p\u003e\n  \u003cdiv style=\"width:100%; overflow-x:auto; -webkit-overflow-scrolling:touch;\"\u003e\n    \u003ctable style=\"width:100%; min-width:760px; border-collapse:collapse;\"\u003e\n      \u003cthead\u003e\n        \u003ctr\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eAssay Kit\u003c\/th\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eManufacturer\u003c\/th\u003e\n          \u003cth style=\"border:1px solid #d9d9d9; padding:10px; text-align:left;\"\u003eCatalog Number\u003c\/th\u003e\n        \u003c\/tr\u003e\n      \u003c\/thead\u003e\n      \u003ctbody\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter dsDNA HS Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1002\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter dsDNA BR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1004\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter 1× dsDNA HS Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1005\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter RNA HS Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1006\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter RNA BR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1007\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eStarLighter ssDNA Assay Kit-V2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eBeijing ForeverStar Biotech\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eFS-T1008-V2\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003edsDNA HS Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ32851\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit dsDNA BR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ32850\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit ssDNA Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ10212\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit RNA HS Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ32852\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit Protein BR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eA50668 \/ A50669\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit RNA BR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ10210\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003ctr\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQubit RNA XR Assay Kit\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eThermo Fisher\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d9d9d9; padding:10px;\"\u003eQ33223\u003c\/td\u003e\n\u003c\/tr\u003e\n      \u003c\/tbody\u003e\n    \u003c\/table\u003e\n  \u003c\/div\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eApplication\u003c\/h2\u003e\n  \u003cp\u003eThe StarLighter S96 is designed for fluorescence-based quantitative detection using a 96-well flat-bottom black microplate. Supported test applications stated in the user guide include:\u003c\/p\u003e\n  \u003cul\u003e\n    \u003cli\u003edsDNA quantitative detection\u003c\/li\u003e\n    \u003cli\u003essDNA quantitative detection\u003c\/li\u003e\n    \u003cli\u003eRNA quantitative detection\u003c\/li\u003e\n    \u003cli\u003emicroRNA quantitative detection\u003c\/li\u003e\n    \u003cli\u003eProtein quantitative detection\u003c\/li\u003e\n    \u003cli\u003eOligo measurement\u003c\/li\u003e\n    \u003cli\u003eBlue-light fluorescence scanning\u003c\/li\u003e\n    \u003cli\u003eRed-light fluorescence scanning\u003c\/li\u003e\n    \u003cli\u003eRFU fluorescence-value measurement\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eThe instrument is intended for indoor laboratory research use only. It is not intended for diagnostic or therapeutic procedures.\u003c\/p\u003e\n\u003c\/section\u003e\n\n\u003csection\u003e\n  \u003ch2\u003eFAQ\u003c\/h2\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eWhat is the StarLighter S96 FS-M2005?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe StarLighter S96 FS-M2005 is a 96-well fluorometer designed for quantitative fluorescence detection of dsDNA, ssDNA, RNA, microRNA, and proteins. It uses two fluorescence channels, LED excitation, top detection, and an SiPMT detector.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eHow many samples can the FS-M2005 measure per run?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe instrument provides 96 sample positions and completes a whole-plate measurement in 55 seconds.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eWhat sample volume and microplate are required?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe sample volume can be set from 1 to 20 µL. The combined sample and working-solution volume must be 200 µL per well. The instrument uses a 0.3 mL 96-well flat-bottom black ELISA plate measuring 128 × 86 × 15 mm, with a maximum consumable height of 15 mm.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eWhat are the sensitivity and detection ranges?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe specified sensitivities are 0.05 ng\/µL for dsDNA, 0.1 ng\/µL for ssDNA, 0.5 ng\/µL for RNA, and 0.1 ng\/µL for microRNA. The detection ranges are 0.01–100 ng\/µL for DNA HS, 1–1000 ng\/µL for DNA BR, 0.25–100 ng\/µL for RNA, and 1–1000 ng\/µL for RNA BR.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eWhat fluorescence wavelengths does the instrument use?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe blue excitation channel covers 457–483 nm with green emission detection at 520–540 nm. The red excitation channel covers 622–638 nm with red emission detection at 672–712 nm.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eWhich assay kits are listed for use with the fluorometer?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eThe user guide lists StarLighter dsDNA HS, dsDNA BR, 1× dsDNA HS, RNA HS, RNA BR, and ssDNA Assay Kit-V2 products. It also lists specific Thermo Fisher dsDNA, ssDNA, RNA, and Protein assay kits with their catalog numbers.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eCan the results be exported to Excel?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eYes. The PC software supports protocol management, standard-curve calculations, result storage, experiment notes, historical-data import, and Excel-format data export.\u003c\/p\u003e\n  \u003c\/details\u003e\n\n  \u003cdetails\u003e\n    \u003csummary\u003e\u003cstrong\u003eIs the StarLighter S96 intended for diagnostic use?\u003c\/strong\u003e\u003c\/summary\u003e\n    \u003cp\u003eNo. The StarLighter S96 FS-M2005 is for research use only and is not intended for diagnostic or therapeutic procedures.\u003c\/p\u003e\n  \u003c\/details\u003e\n\u003c\/section\u003e","brand":"Qihengxing","offers":[{"title":"Default Title","offer_id":53189699109045,"sku":"FS-M2005","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/starlighter-s96-fs-m2005-96-well-fluorometer.png?v=1788157628","url":"https:\/\/biofargo.com\/products\/s96-96-well-fluorometer-fs-m2005-starlighter","provider":"Biofargo","version":"1.0","type":"link"}