{"product_id":"s96-96-well-fluorometer-for-dna-rna-and-protein-quantification","title":"S96 96-Well Fluorometer for DNA, RNA and Protein Quantification","description":"\u003cstyle\u003e\n  .bf-rich .josh-faq {\n    background: #fff;\n    color: #000;\n    font-family: \"IBM Plex Sans\", sans-serif;\n  }\n\n  .bf-rich .josh-faq__inner { padding: 30px 300px 60px 30px; }\n  .bf-rich .josh-faq__item { border-bottom: 1px solid #e5e7eb; padding: 0; }\n  .bf-rich .josh-faq__item:first-child { border-top: 1px solid #e5e7eb; }\n\n  .bf-rich .josh-faq__question {\n    width: 100%;\n    margin: 0;\n    padding: 20px 0;\n    display: flex;\n    align-items: center;\n    justify-content: space-between;\n    gap: 16px;\n    color: #505052;\n    background: none;\n    border: 0;\n    font: 700 16px\/1.4 \"IBM Plex Sans\", sans-serif;\n    text-align: left;\n    cursor: pointer;\n    list-style: none;\n  }\n\n  .bf-rich .josh-faq__question::-webkit-details-marker { display: none; }\n  .bf-rich .josh-faq__question:hover { color: #505052; }\n\n  .bf-rich .josh-faq__icon {\n    position: relative;\n    width: 20px;\n    height: 20px;\n    flex: 0 0 20px;\n    transition: transform .25s ease;\n  }\n\n  .bf-rich .josh-faq__icon::before,\n  .bf-rich .josh-faq__icon::after {\n    position: absolute;\n    content: \"\";\n    background: currentColor;\n    border-radius: 2px;\n    transition: opacity .25s ease, transform .25s ease;\n  }\n\n  .bf-rich .josh-faq__icon::before {\n    top: 50%;\n    left: 0;\n    width: 100%;\n    height: 2px;\n    transform: translateY(-50%);\n  }\n\n  .bf-rich .josh-faq__icon::after {\n    top: 0;\n    left: 50%;\n    width: 2px;\n    height: 100%;\n    transform: translateX(-50%);\n  }\n\n  .bf-rich .josh-faq__item[open] .josh-faq__icon::after {\n    opacity: 0;\n    transform: translateX(-50%) rotate(90deg);\n  }\n\n  .bf-rich .josh-faq__answer {\n    max-width: 860px;\n    padding: 0 0 20px;\n    color: #505052;\n    font: 400 16px\/1.6 \"IBM Plex Sans\", sans-serif;\n  }\n\n  .bf-rich .josh-faq__answer p { margin: 0 0 15px; color: #505052; font: inherit; }\n  .bf-rich .josh-faq__answer p:last-child { margin-bottom: 0; }\n  .bf-rich .josh-faq__answer ul { margin: 8px 0 12px; padding-left: 22px; }\n  .bf-rich .josh-faq__answer li { margin-bottom: 6px; font: inherit; list-style-type: disc; }\n\n  @media (max-width: 767px) {\n    .bf-rich .josh-faq__inner { padding: 24px 0 40px; }\n    .bf-rich .josh-faq__question { padding: 16px 0; font-size: 15px; }\n    .bf-rich .josh-faq__answer { font-size: 15px; }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"bf-rich\"\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe StarLighter Fluorometer S96 is a compact fluorescence reader designed for quantitative detection of DNA, RNA, microRNA, and proteins. It processes up to 96 samples using a 0.3 mL 96-well flat-bottom black ELISA plate and requires 1–20 μL of sample per well.\u003c\/p\u003e\n\u003cp\u003eThe instrument uses two fluorescence channels, LED light sources, a SiPMT detector, and top-reading detection. A complete 96-well plate can be read in 55 seconds. Supported test items include dsDNA, ssDNA, RNA, microRNA, proteins, and fluorescence intensity measurements.\u003c\/p\u003e\n\u003cp\u003eSamples are combined with the appropriate working solution to a total volume of 200 μL per well. The instrument is operated through PC software that supports protocol creation, sample and well configuration, result review, data import, and Excel-format data export.\u003c\/p\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic or therapeutic procedures.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 90%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eStarLighter Fluorometer S96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eFS-M2005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSample Volume\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1–20 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTotal Reaction Volume\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e200 μL per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSample Throughput\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eCompatible Consumable\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.3 mL 96-well flat-bottom black ELISA plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eCompatible Plate Dimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e128 × 86 × 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eMaximum Consumable Height\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRead Time\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e55 seconds per whole plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eLED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eFluorescence Channels\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlue Excitation Wavelength\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e457–483 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRed Excitation Wavelength\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e622–638 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eGreen Emission Wavelength\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e520–540 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRed Emission Wavelength\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e672–712 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDetector\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSiPMT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDetection Method\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eTop detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eSample Types\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003edsDNA, ssDNA, RNA, microRNA, and proteins\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003edsDNA Sensitivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.05 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003essDNA Sensitivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNA Sensitivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.5 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003emicroRNA Sensitivity\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003edsDNA HS Detection Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.01–100 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003edsDNA BR Detection Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1–1000 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNA Detection Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.25–100 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eRNA BR Detection Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1–1000 ng\/μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eCalibration\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDynamic Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e5 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBluetooth and serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDC 24 V, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e15–30°C, \u0026lt;75% RH, indoor use only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e274 × 180 × 106 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e2.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e96-Sample Throughput: The instrument processes up to 96 samples using a 0.3 mL 96-well flat-bottom black ELISA plate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast Whole-Plate Reading: A complete 96-well plate can be read in 55 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow Sample Input: Each reaction requires 1–20 μL of sample, with working solution added to a total volume of 200 μL per well.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo Fluorescence Channels: The instrument provides blue and red excitation channels with green and red emission detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple Sample Types: Supported sample types include dsDNA, ssDNA, RNA, microRNA, and proteins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTop-Reading Detection: Fluorescence is measured from the top of the microplate using a SiPMT detector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTwo-Point Calibration: Quantitative measurements are generated using two-point calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFive-Order Dynamic Range: The instrument provides a dynamic range of five orders of magnitude.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePC Software Operation: The software supports protocol creation, well selection, sample information entry, experiment control, result review, data import, and data export.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBilingual Software: The software interface supports Chinese and English.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcel Data Export: Saved experimental results can be exported in Excel format.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003edsDNA Quantification:\u003c\/strong\u003e Quantitative fluorescence measurement of double-stranded DNA samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003essDNA Quantification:\u003c\/strong\u003e Quantitative fluorescence measurement of single-stranded DNA samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRNA Quantification:\u003c\/strong\u003e Quantitative fluorescence measurement of RNA samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003emicroRNA Quantification:\u003c\/strong\u003e Quantitative fluorescence measurement of microRNA samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtein Quantification:\u003c\/strong\u003e Quantitative fluorescence measurement of protein samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRFU Measurement:\u003c\/strong\u003e Measurement of fluorescence intensity without a standard curve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\u003cp\u003eCommon questions about the StarLighter Fluorometer S96.\u003c\/p\u003e\n\u003cdiv class=\"josh-faq\"\u003e\n\u003csection class=\"josh-faq__inner\"\u003e\n\u003cdiv class=\"josh-faq__list\"\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eWhat can the StarLighter Fluorometer S96 measure? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eThe instrument is designed for quantitative fluorescence detection of dsDNA, ssDNA, RNA, microRNA, and proteins. It can also measure fluorescence intensity in RFU mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eHow many samples can be measured in one run? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eThe instrument supports up to 96 samples using a 0.3 mL 96-well flat-bottom black ELISA plate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eHow long does it take to read a complete plate? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eA complete 96-well plate can be read in 55 seconds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eHow much sample is required per well? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eEach well requires 1–20 μL of sample. Add 180–199 μL of working solution so that the total volume in each well is 200 μL.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eWhat microplate is compatible with the instrument? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eUse a 0.3 mL 96-well flat-bottom black ELISA plate measuring 128 × 86 × 15 mm. The height of the consumable must not exceed 15 mm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eDoes the instrument require a computer? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eYes. The instrument must be connected to a computer using the supplied USB cable. The PC software is used to create protocols, configure wells, run experiments, review results, and export data.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eHow long should the instrument stabilize after power-on? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eAllow the instrument to stabilize for 15 minutes after power-on before use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"josh-faq__item\"\u003e\n\u003csummary class=\"josh-faq__question\"\u003eIs the instrument intended for diagnostic use? \u003cspan class=\"josh-faq__icon\"\u003e\u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"josh-faq__answer\"\u003e\n\u003cp\u003eNo. The instrument is for research use only and is not intended for diagnostic or therapeutic procedures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" type=\"application\/pdf\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Fluorometer_S96-User_guide-Biofargo.pdf?v=1790144258\" target=\"_blank\"\u003e\u003cstrong\u003eProduct User Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Qihengxing","offers":[{"title":"Default Title","offer_id":53370539311285,"sku":"FS-M2005","price":6600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/S96_96-Well_Fluorometer.jpg?v=1790146192","url":"https:\/\/biofargo.com\/products\/s96-96-well-fluorometer-for-dna-rna-and-protein-quantification","provider":"Biofargo","version":"1.0","type":"link"}