{"product_id":"rat-noradrenaline-elisa-kit","title":"Rat Noradrenaline (Norepinephrine) ELISA Kit","description":"\u003c!-- =========================\nPRODUCT DESCRIPTION\n========================= --\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eAccurate measurement of \u003cstrong\u003enoradrenaline (norepinephrine, NE)\u003c\/strong\u003e levels is important for understanding catecholamine regulation, sympathetic nervous system activity, and neuroendocrine responses in animal research models. Changes in norepinephrine concentration may reflect alterations in stress response pathways, autonomic regulation, cardiovascular function, and neurotransmitter metabolism. Reliable quantification of rat NE levels requires a sensitive and reproducible assay capable of analyzing complex biological samples.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Noradrenaline (Norepinephrine) ELISA Kit\u003c\/strong\u003e is designed for quantitative detection of noradrenaline levels in rat biological samples using a \u003cstrong\u003edouble antibody sandwich ELISA method\u003c\/strong\u003e. This research-use-only ELISA kit provides a convenient solution for researchers performing \u003cstrong\u003erat norepinephrine analysis\u003c\/strong\u003e in serum, plasma, cell culture supernatants, and tissue homogenates.\u003c\/p\u003e\n\u003cp\u003eNoradrenaline, also known as norepinephrine, is a major \u003cstrong\u003ecatecholamine neurotransmitter\u003c\/strong\u003e involved in neuronal signaling, sympathetic nervous system activation, and physiological stress responses. Measuring NE concentration in rat experimental samples can support studies focused on neuroscience, stress biology, cardiovascular regulation, pharmacological evaluation, and neuroendocrine mechanisms.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Norepinephrine ELISA Kit\u003c\/strong\u003e utilizes pre-coated microplate wells, HRP-labeled detection antibodies, and TMB colorimetric detection technology. After antigen-antibody binding and enzymatic reaction, the optical density is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e, and sample concentrations are calculated according to the generated standard curve.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003eRat Noradrenaline ELISA Kit\u003c\/strong\u003e is intended for \u003cstrong\u003eResearch Use Only (RUO)\u003c\/strong\u003e and is not designed for clinical diagnosis, therapeutic applications, or human testing.\u003c\/p\u003e\n\u003c!-- =========================\nSPECIFICATIONS\n========================= --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"8\" border=\"1\" style=\"width: 90%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRat Noradrenaline (Norepinephrine) ELISA Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlternative Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRat Norepinephrine ELISA Kit; Rat NE ELISA Kit; Noradrenaline (NE) ELISA Assay Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYX-140500R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTarget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNoradrenaline \/ Norepinephrine (NE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDouble Antibody Sandwich ELISA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eColorimetric ELISA Detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRat Serum, Rat Plasma, Cell Culture Supernatant, Rat Tissue Homogenate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–8 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Concentrations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0, 0.5, 1, 2, 4, 8 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Dilution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-fold dilution before calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2–8°C, protected from light and moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResearch Use Only (RUO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- =========================\nFEATURES\n========================= --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat-Specific Noradrenaline Detection:\u003c\/strong\u003e Designed for quantitative measurement of \u003cstrong\u003erat norepinephrine (NE)\u003c\/strong\u003e levels in experimental biological samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDouble Antibody Sandwich ELISA Format:\u003c\/strong\u003e Uses antibody-based capture and HRP-labeled detection systems to provide reliable quantitative analysis of noradrenaline concentrations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensitive Catecholamine Measurement:\u003c\/strong\u003e Provides a detection sensitivity of less than \u003cstrong\u003e0.1 ng\/mL\u003c\/strong\u003e for studying low-abundance neurotransmitter biomarkers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Biological Sample Compatibility:\u003c\/strong\u003e Suitable for rat serum, plasma, tissue homogenates, and cell culture supernatants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandard Curve-Based Quantification:\u003c\/strong\u003e Includes calibrated NE standards for calculating sample concentrations through OD450 measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eColorimetric Microplate Detection:\u003c\/strong\u003e Compatible with standard microplate readers using 450 nm absorbance detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Applications in Catecholamine Biology:\u003c\/strong\u003e Supports neuroscience, stress response, cardiovascular, and pharmacological research involving noradrenaline signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Use Only:\u003c\/strong\u003e For laboratory research applications only and not intended for diagnostic or therapeutic use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- =========================\nASSAY PRINCIPLE\n========================= --\u003e\n\u003ch2\u003eAssay Principle\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Noradrenaline (Norepinephrine) ELISA Kit\u003c\/strong\u003e is based on a \u003cstrong\u003edouble antibody sandwich ELISA principle\u003c\/strong\u003e. Microplate wells are pre-coated with antibodies specific to noradrenaline. When rat samples or standards are added, NE binds to the capture antibodies immobilized on the plate.\u003c\/p\u003e\n\u003cp\u003eAfter incubation and washing, an \u003cstrong\u003eHRP-conjugated detection antibody\u003c\/strong\u003e is added to form an antibody-antigen-antibody complex. Following additional washing steps, TMB substrate is introduced. HRP catalyzes the color reaction, and the intensity of the generated color is measured at \u003cstrong\u003e450 nm\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe optical density value is proportional to the concentration of noradrenaline present in the sample. Sample concentrations are determined by comparing measured OD values with the NE standard curve.\u003c\/p\u003e\n\u003c!-- =========================\nAPPLICATIONS\n========================= --\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Noradrenaline ELISA Kit\u003c\/strong\u003e provides quantitative detection of norepinephrine for a variety of laboratory animal research applications involving catecholamine signaling, autonomic regulation, and physiological responses.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat Neuroscience Research:\u003c\/strong\u003e Measurement of norepinephrine levels to investigate neurotransmitter regulation, neuronal signaling pathways, and neurochemical changes in rat models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat Stress Response Studies:\u003c\/strong\u003e Analysis of NE concentration changes associated with physiological stress, environmental stimulation, and stress-related biological responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSympathetic Nervous System Research:\u003c\/strong\u003e Evaluation of sympathetic activation and autonomic nervous system regulation through quantitative rat norepinephrine detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCardiovascular Research:\u003c\/strong\u003e Investigation of catecholamine-related mechanisms involved in cardiovascular regulation, adrenergic signaling, and vascular responses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNeuroendocrine Studies:\u003c\/strong\u003e Research on hormone-neurotransmitter interactions and biological pathways involving catecholamine regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePharmacological Research:\u003c\/strong\u003e Assessment of drug-induced changes in noradrenaline metabolism and neurotransmitter-related pathways in rat models.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAnimal Model Studies:\u003c\/strong\u003e Quantitative monitoring of norepinephrine levels in rat experimental models for physiological and biochemical research.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBiomarker Analysis:\u003c\/strong\u003e Supports laboratory investigation of NE as a catecholamine biomarker in biological samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- =========================\nSAMPLE TYPES\n========================= --\u003e\n\u003ch2\u003eSample Types\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Noradrenaline (Norepinephrine) ELISA Kit\u003c\/strong\u003e is compatible with commonly used rat biological samples for catecholamine research. Proper sample preparation is essential for obtaining accurate and reproducible norepinephrine measurements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat Serum:\u003c\/strong\u003e Serum samples collected using appropriate tubes and centrifuged to separate serum from blood cells before analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat Plasma:\u003c\/strong\u003e Plasma samples collected with EDTA, citrate, or heparin anticoagulants for norepinephrine quantification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRat Tissue Homogenate:\u003c\/strong\u003e Tissue samples homogenized with physiological saline and centrifuged to obtain supernatant for NE detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCell Culture Supernatant:\u003c\/strong\u003e Cell-derived biological fluids processed by centrifugation to remove particles and suitable for ELISA analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOther Rat Biological Samples:\u003c\/strong\u003e Additional experimental samples may be evaluated according to specific research requirements and sample preparation procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- =========================\nASSAY WORKFLOW\n========================= --\u003e\n\u003ch2\u003eAssay Workflow\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Norepinephrine ELISA Kit\u003c\/strong\u003e provides a straightforward microplate-based workflow for quantitative NE analysis.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003eBring all reagents and samples to room temperature before starting the assay. Remove the required microplate strips from the sealed package and equilibrate for approximately 20 minutes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd \u003cstrong\u003e50 μL of NE standards\u003c\/strong\u003e into standard wells to generate the calibration curve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd \u003cstrong\u003e10 μL of rat sample\u003c\/strong\u003e followed by \u003cstrong\u003e40 μL of sample diluent\u003c\/strong\u003e into sample wells.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd \u003cstrong\u003e100 μL of HRP-conjugated detection antibody\u003c\/strong\u003e into each well except blank wells, then incubate at \u003cstrong\u003e37°C for 60 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWash the plate thoroughly to remove unbound components. Proper washing is important for reducing background signal and improving assay consistency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd \u003cstrong\u003e50 μL substrate solution A\u003c\/strong\u003e and \u003cstrong\u003e50 μL substrate solution B\u003c\/strong\u003e to each well, then incubate at \u003cstrong\u003e37°C for 15 minutes protected from light\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdd \u003cstrong\u003e50 μL stop solution\u003c\/strong\u003e to terminate the reaction and measure absorbance at \u003cstrong\u003e450 nm\u003c\/strong\u003e within 15 minutes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalculate rat norepinephrine concentration using the standard curve generated from the provided NE standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c!-- =========================\nPERFORMANCE CHARACTERISTICS\n========================= --\u003e\n\u003ch2\u003ePerformance Characteristics\u003c\/h2\u003e\n\u003ctable style=\"width: 90%; border-collapse: collapse;\" border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard curve correlation coefficient (R) ≥ 0.9900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1 ng\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecificity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo significant cross-reactivity with other soluble structural analogs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrecision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntra-assay and inter-assay coefficient of variation \u0026lt;15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2–8°C, avoid light and moisture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValidity Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- =========================\nFAQ\n========================= --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the Rat Noradrenaline (Norepinephrine) ELISA Kit used for?\u003c\/summary\u003e\n\u003cp\u003eThe \u003cstrong\u003eRat Noradrenaline ELISA Kit\u003c\/strong\u003e is used for quantitative measurement of norepinephrine (NE) levels in rat biological samples. It supports research applications including neuroscience studies, stress response analysis, cardiovascular research, and catecholamine pathway investigations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat samples can be tested with a Rat Norepinephrine ELISA Kit?\u003c\/summary\u003e\n\u003cp\u003eThis \u003cstrong\u003eRat Norepinephrine ELISA Kit\u003c\/strong\u003e is suitable for rat serum, rat plasma, cell culture supernatants, and rat tissue homogenates. Samples should be properly prepared and processed according to the recommended protocol.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the detection principle of this Rat NE ELISA Kit?\u003c\/summary\u003e\n\u003cp\u003eThe kit uses a \u003cstrong\u003edouble antibody sandwich ELISA method\u003c\/strong\u003e. Noradrenaline in samples is captured by immobilized antibodies and detected using an HRP-labeled detection antibody. The resulting TMB color reaction is measured at 450 nm to determine NE concentration.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhy measure norepinephrine levels in rat models?\u003c\/summary\u003e\n\u003cp\u003eNorepinephrine is an important catecholamine neurotransmitter involved in sympathetic nervous system activity and physiological stress responses. Measuring rat NE levels can help researchers evaluate changes in neurochemical regulation, autonomic function, and stress-related pathways.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the standard concentration range of this Rat Noradrenaline ELISA Kit?\u003c\/summary\u003e\n\u003cp\u003eThe provided NE standards include concentrations of \u003cstrong\u003e0, 0.5, 1, 2, 4, and 8 ng\/mL\u003c\/strong\u003e. Sample concentrations are calculated by comparing measured OD450 values with the generated standard curve.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat equipment is required for the Rat Norepinephrine ELISA assay?\u003c\/summary\u003e\n\u003cp\u003eThe assay requires a microplate reader capable of measuring absorbance at \u003cstrong\u003e450 nm\u003c\/strong\u003e, precision pipettes, disposable pipette tips, and a 37°C incubator or temperature-controlled device.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan this Rat Noradrenaline ELISA Kit be used for clinical diagnosis?\u003c\/summary\u003e\n\u003cp\u003eNo. This product is intended for \u003cstrong\u003eResearch Use Only (RUO)\u003c\/strong\u003e and is not approved for diagnostic, therapeutic, or human testing applications.\u003c\/p\u003e\n\u003c\/details\u003e","brand":"Yuan Xin","offers":[{"title":"48T","offer_id":52776338358453,"sku":"YX-140500R-48T","price":360.0,"currency_code":"USD","in_stock":true},{"title":"96T","offer_id":52776331509941,"sku":"YX-140500R-96T","price":540.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Rat_Noradrenaline_Norepinephrine_ELISA_Kit.jpg?v=1783492155","url":"https:\/\/biofargo.com\/products\/rat-noradrenaline-elisa-kit","provider":"Biofargo","version":"1.0","type":"link"}