{"product_id":"mini-two-gel-wet-transfer-system-for-protein-blotting","title":"Mini Two-Gel Wet Transfer System for Protein Blotting","description":"\u003cstyle\u003e\n  .biofargo-product {\n    max-width: 1000px;\n    margin: 0 auto;\n    padding: 0;\n    color: #333333;\n    font-family: Arial, Helvetica, sans-serif;\n    font-size: 16px;\n    line-height: 1.7;\n  }\n\n  .biofargo-product h2 {\n    margin: 34px 0 14px;\n    padding: 0;\n    color: #333333;\n    font-size: 24px;\n    line-height: 1.3;\n    font-weight: 700;\n  }\n\n  .biofargo-product section:first-child h2 {\n    margin-top: 0;\n  }\n\n  .biofargo-product p {\n    margin: 0 0 14px;\n  }\n\n  .biofargo-product ul {\n    margin: 10px 0 0;\n    padding-left: 24px;\n  }\n\n  .biofargo-product li {\n    margin-bottom: 9px;\n  }\n\n  .biofargo-table-wrap {\n    display: block;\n    width: 100%;\n    max-width: 100%;\n    overflow-x: auto;\n    border: 1px solid #999999;\n    border-radius: 3px;\n    -webkit-overflow-scrolling: touch;\n  }\n\n  .biofargo-spec-table {\n    width: 100%;\n    min-width: 620px;\n    margin: 0;\n    border: 0;\n    border-collapse: collapse;\n    background: #ffffff;\n  }\n\n  .biofargo-spec-table th,\n  .biofargo-spec-table td {\n    padding: 10px 14px;\n    vertical-align: middle;\n    border-right: 1px solid #999999;\n    border-bottom: 1px solid #999999;\n  }\n\n  .biofargo-spec-table th:last-child,\n  .biofargo-spec-table td:last-child {\n    border-right: 0;\n  }\n\n  .biofargo-spec-table tbody tr:last-child td {\n    border-bottom: 0;\n  }\n\n  .biofargo-spec-table thead th {\n    color: #ffffff;\n    background: #0b5da9;\n    text-align: center;\n    font-weight: 700;\n  }\n\n  .biofargo-spec-table thead th:first-child,\n  .biofargo-spec-table tbody td:first-child {\n    width: 36%;\n  }\n\n  .biofargo-spec-table tbody td:first-child {\n    background: #f1f2f3;\n    text-align: center;\n    font-weight: 700;\n  }\n\n  .biofargo-spec-table tbody td:nth-child(2) {\n    background: #ffffff;\n    text-align: center;\n  }\n\n  .biofargo-faq {\n    width: 100%;\n    border-top: 1px solid #dddddd;\n  }\n\n  .biofargo-faq details {\n    margin: 0;\n    padding: 0;\n    border: 0;\n    border-bottom: 1px solid #dddddd;\n    border-radius: 0;\n    background: transparent;\n  }\n\n  .biofargo-faq summary {\n    padding: 12px 0;\n    color: #333333;\n    background: transparent;\n    cursor: pointer;\n    font-weight: 700;\n    line-height: 1.5;\n  }\n\n  .biofargo-faq details p {\n    margin: 0;\n    padding: 0 0 14px 18px;\n    color: #444444;\n  }\n\n  @media (max-width: 600px) {\n    .biofargo-product {\n      font-size: 15px;\n    }\n\n    .biofargo-product h2 {\n      font-size: 21px;\n    }\n\n    .biofargo-table-wrap {\n      overflow-x: auto;\n    }\n\n    .biofargo-spec-table {\n      min-width: 580px;\n    }\n\n    .biofargo-spec-table th,\n    .biofargo-spec-table td {\n      padding: 9px 12px;\n      font-size: 14px;\n    }\n\n    .biofargo-faq summary {\n      padding: 11px 0;\n    }\n  }\n\u003c\/style\u003e\n\u003carticle class=\"biofargo-product\"\u003e\n\u003csection id=\"description\"\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eLaboratories transferring protein samples from small gels may need to process more than one gel while maintaining the correct transfer orientation and controlling the heat generated during the transfer process. This mini wet transfer system is designed for rapid, high-quality blot transfer of small gels and transfer electrophoresis of protein samples.\u003c\/p\u003e\n\u003cp\u003eThe two gel transfer system accommodates two gel holder sandwich transfer cassettes. Two 75 × 100 mm gels can be transferred simultaneously within one hour, while lower-intensity operation supports overnight transfer.\u003c\/p\u003e\n\u003cp\u003eThe electrode wires are positioned 4 cm apart. This close electrode spacing produces a strong electric field for efficient protein transfer. The electrophoretic protein transfer system uses 99.99% high-purity platinum electrode wire for conductivity and corrosion resistance.\u003c\/p\u003e\n\u003cp\u003eRed and black markings identify the transfer cassettes and electrodes, helping users maintain the correct gel orientation during transfer. A dedicated open gel sandwich cassette supports straightforward operation, while the included blue ice box absorbs heat generated during the transfer process.\u003c\/p\u003e\n\u003cp\u003eThe mini gel transfer tank is manufactured from high-transparency injection-molded polycarbonate. It is compatible with the buffer tank and cover of the corresponding vertical electrophoresis tank.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specification\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"biofargo-table-wrap\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable class=\"biofargo-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMini wet transfer system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Method\u003c\/td\u003e\n\u003ctd\u003eWet transfer electrophoresis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eBlot transfer of small gels and transfer electrophoresis of protein samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Area\u003c\/td\u003e\n\u003ctd\u003e100 × 75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel Capacity\u003c\/td\u003e\n\u003ctd\u003eTwo gels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGel Size\u003c\/td\u003e\n\u003ctd\u003e75 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Cassettes\u003c\/td\u003e\n\u003ctd\u003eTwo gel holder sandwich transfer cassettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Distance\u003c\/td\u003e\n\u003ctd\u003e4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Wire\u003c\/td\u003e\n\u003ctd\u003e99.99% high-purity platinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank Construction\u003c\/td\u003e\n\u003ctd\u003eHigh-transparency injection-molded polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransfer Options\u003c\/td\u003e\n\u003ctd\u003eTwo gels within one hour or lower-intensity overnight transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrientation Identification\u003c\/td\u003e\n\u003ctd\u003eRed and black markings on the transfer cassettes and electrodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Unit\u003c\/td\u003e\n\u003ctd\u003eBlue ice box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCompatible with the buffer tank and cover of the corresponding vertical electrophoresis tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Buffer Tank\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Top Cover\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Electrophoretic Wire\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Electrotransfer Core Module\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Gel Holder Cassettes\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Blotting Filter Pads\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Cooling Unit\u003c\/td\u003e\n\u003ctd\u003e1 blue ice box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"features\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimultaneous two-gel transfer:\u003c\/strong\u003e Two 75 × 100 mm gels can be transferred at the same time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid and overnight transfer options:\u003c\/strong\u003e The mini blotting system supports transfer within one hour or lower-intensity overnight transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClose electrode spacing:\u003c\/strong\u003e The electrode wires are positioned 4 cm apart to produce a strong electric field for efficient protein transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-purity platinum electrode wire:\u003c\/strong\u003e The 99.99% high-purity platinum electrode wire provides conductivity and corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor-coded transfer orientation:\u003c\/strong\u003e Red and black markings on the transfer cassettes and electrodes help maintain the correct gel orientation during transfer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen gel sandwich cassettes:\u003c\/strong\u003e The dedicated open cassette design supports straightforward transfer sandwich operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated cooling unit:\u003c\/strong\u003e The included blue ice box absorbs heat generated during the transfer process.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent polycarbonate tank:\u003c\/strong\u003e The tank is manufactured from high-transparency injection-molded polycarbonate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared tank compatibility:\u003c\/strong\u003e The wet transfer module is compatible with the buffer tank and cover of the corresponding vertical electrophoresis tank.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection id=\"application\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRapid, high-quality blot transfer of small gels.\u003c\/li\u003e\n\u003cli\u003eTransfer electrophoresis of protein samples.\u003c\/li\u003e\n\u003cli\u003eSimultaneous transfer of two 75 × 100 mm gels.\u003c\/li\u003e\n\u003cli\u003eProtein transfer completed within one hour.\u003c\/li\u003e\n\u003cli\u003eLower-intensity overnight transfer.\u003c\/li\u003e\n\u003cli\u003eTransfer operation using the buffer tank and cover of the corresponding vertical electrophoresis tank.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection id=\"faq\"\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"biofargo-faq\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is this mini wet transfer system used for?\u003c\/summary\u003e\n\u003cp\u003eIt is used for rapid, high-quality blot transfer of small gels and transfer electrophoresis of protein samples.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow many gels can the transfer system process?\u003c\/summary\u003e\n\u003cp\u003eThe two gel transfer system accommodates two gel holder sandwich transfer cassettes and can transfer two gels simultaneously.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat gel size can the mini gel transfer tank accommodate?\u003c\/summary\u003e\n\u003cp\u003eThe system is designed to transfer two 75 × 100 mm gels.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the transfer area?\u003c\/summary\u003e\n\u003cp\u003eThe transfer area is 100 × 75 mm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow long does the protein transfer process take?\u003c\/summary\u003e\n\u003cp\u003eTwo 75 × 100 mm gels can be transferred simultaneously within one hour. The system also supports lower-intensity overnight transfer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the system support overnight transfer?\u003c\/summary\u003e\n\u003cp\u003eYes. In addition to transfer within one hour, the system can be used for lower-intensity overnight transfer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the distance between the electrode wires?\u003c\/summary\u003e\n\u003cp\u003eThe electrode wires are positioned 4 cm apart to produce a strong electric field for efficient protein transfer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat material is used for the electrode wire?\u003c\/summary\u003e\n\u003cp\u003eThe electrophoretic protein transfer system uses 99.99% high-purity platinum electrode wire for conductivity and corrosion resistance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow does the system identify the correct transfer orientation?\u003c\/summary\u003e\n\u003cp\u003eRed and black markings identify the transfer cassettes and electrodes, helping users maintain the correct gel orientation during transfer.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat type of transfer cassette is included?\u003c\/summary\u003e\n\u003cp\u003eThe system includes two dedicated open gel holder sandwich transfer cassettes.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the transfer tank include a cooling unit?\u003c\/summary\u003e\n\u003cp\u003eYes. One blue ice box is included to absorb heat generated during the transfer process.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the transfer tank made from?\u003c\/summary\u003e\n\u003cp\u003eThe tank is made from high-transparency injection-molded polycarbonate.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eIs the transfer module compatible with a vertical electrophoresis tank?\u003c\/summary\u003e\n\u003cp\u003eThe transfer module is compatible with the buffer tank and cover of the corresponding vertical electrophoresis tank.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow many blotting filter pads are included?\u003c\/summary\u003e\n\u003cp\u003eFour blotting filter pads are included.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat components are supplied with the system?\u003c\/summary\u003e\n\u003cp\u003eThe supplied components include one buffer tank, one top cover, one electrophoretic wire, one electrotransfer core module, two gel holder sandwich transfer cassettes, four blotting filter pads and one blue ice box.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"ZKYY","offers":[{"title":"Default Title","offer_id":53263995732149,"sku":"BF-BT02","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/mini-two-gel-wet-transfer-system.jpg?v=1789378293","url":"https:\/\/biofargo.com\/products\/mini-two-gel-wet-transfer-system-for-protein-blotting","provider":"Biofargo","version":"1.0","type":"link"}