{"product_id":"mini-four-gel-vertical-electrophoresis-tank","title":"Mini Four Gel Vertical Electrophoresis Tank","description":"\u003cstyle\u003e\n  .biofargo-product {\n    max-width: 1000px;\n    margin: 0 auto;\n    padding: 0;\n    color: #333333;\n    font-family: Arial, Helvetica, sans-serif;\n    font-size: 16px;\n    line-height: 1.7;\n  }\n\n  .biofargo-product h2 {\n    margin: 34px 0 14px;\n    padding: 0;\n    color: #333333;\n    font-size: 24px;\n    line-height: 1.3;\n    font-weight: 700;\n  }\n\n  .biofargo-product section:first-child h2 {\n    margin-top: 0;\n  }\n\n  .biofargo-product p {\n    margin: 0 0 14px;\n  }\n\n  .biofargo-product ul {\n    margin: 10px 0 0;\n    padding-left: 24px;\n  }\n\n  .biofargo-product li {\n    margin-bottom: 9px;\n  }\n\n  .biofargo-table-wrap {\n    display: block;\n    width: 100%;\n    max-width: 100%;\n    overflow-x: auto;\n    border: 1px solid #999999;\n    border-radius: 3px;\n    -webkit-overflow-scrolling: touch;\n  }\n\n  .biofargo-spec-table {\n    width: 100%;\n    min-width: 620px;\n    margin: 0;\n    border: 0;\n    border-collapse: collapse;\n    background: #ffffff;\n  }\n\n  .biofargo-spec-table th,\n  .biofargo-spec-table td {\n    padding: 10px 14px;\n    vertical-align: middle;\n    border-right: 1px solid #999999;\n    border-bottom: 1px solid #999999;\n  }\n\n  .biofargo-spec-table th:last-child,\n  .biofargo-spec-table td:last-child {\n    border-right: 0;\n  }\n\n  .biofargo-spec-table tbody tr:last-child td {\n    border-bottom: 0;\n  }\n\n  .biofargo-spec-table thead th {\n    color: #ffffff;\n    background: #0b5da9;\n    text-align: center;\n    font-weight: 700;\n  }\n\n  .biofargo-spec-table thead th:first-child,\n  .biofargo-spec-table tbody td:first-child {\n    width: 36%;\n  }\n\n  .biofargo-spec-table tbody td:first-child {\n    background: #f1f2f3;\n    text-align: center;\n    font-weight: 700;\n  }\n\n  .biofargo-spec-table tbody td:nth-child(2) {\n    background: #ffffff;\n    text-align: center;\n  }\n\n  .biofargo-faq {\n    width: 100%;\n    border-top: 1px solid #dddddd;\n  }\n\n  .biofargo-faq details {\n    margin: 0;\n    padding: 0;\n    border: 0;\n    border-bottom: 1px solid #dddddd;\n    border-radius: 0;\n    background: transparent;\n  }\n\n  .biofargo-faq summary {\n    padding: 12px 0;\n    color: #333333;\n    background: transparent;\n    cursor: pointer;\n    font-weight: 700;\n    line-height: 1.5;\n  }\n\n  .biofargo-faq details p {\n    margin: 0;\n    padding: 0 0 14px 18px;\n    color: #444444;\n  }\n\n  @media (max-width: 600px) {\n    .biofargo-product {\n      font-size: 15px;\n    }\n\n    .biofargo-product h2 {\n      font-size: 21px;\n    }\n\n    .biofargo-table-wrap {\n      overflow-x: auto;\n    }\n\n    .biofargo-spec-table {\n      min-width: 580px;\n    }\n\n    .biofargo-spec-table th,\n    .biofargo-spec-table td {\n      padding: 9px 12px;\n      font-size: 14px;\n    }\n\n    .biofargo-faq summary {\n      padding: 11px 0;\n    }\n  }\n\u003c\/style\u003e\n\u003carticle class=\"biofargo-product\"\u003e\n\u003csection id=\"description\"\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eLaboratories processing several protein or nucleic acid samples may need to run multiple gels while maintaining consistent glass-plate alignment and reliable gel preparation. This mini four gel vertical electrophoresis tank provides a flexible system for running between one and four gels in a single experimental setup.\u003c\/p\u003e\n\u003cp\u003eThe system supports both precast gels and hand-cast gels. An edge cushion fixed to the long glass plate assists with accurate plate alignment and helps reduce gel leakage. The cam-lock rubber frame is designed for convenient operation and plate alignment during gel preparation.\u003c\/p\u003e\n\u003cp\u003eSpecial plastic well combs do not inhibit the gel polymerization reaction. Their built-in ridges support uniform gel polymerization. A sample-loading guide helps reduce missed lanes and repeated sample loading, while the high-purity platinum electrode wire provides conductive performance.\u003c\/p\u003e\n\u003cp\u003eThe four gel vertical electrophoresis system can accommodate one to four precast gels and complete electrophoresis of up to four small precast gels within one hour.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection id=\"specification\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"biofargo-table-wrap\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable class=\"biofargo-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eItem\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMini four gel vertical electrophoresis tank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Gels\u003c\/td\u003e\n\u003ctd\u003e1–4 gels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Gel Thickness\u003c\/td\u003e\n\u003ctd\u003e1.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Gel Thickness\u003c\/td\u003e\n\u003ctd\u003e0.75 mm and 1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Comb\u003c\/td\u003e\n\u003ctd\u003e1.0 mm, 10-well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Combs\u003c\/td\u003e\n\u003ctd\u003e0.75 mm, 1.0 mm or 1.5 mm; 10-well or 15-well options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Glass Plate\u003c\/td\u003e\n\u003ctd\u003e10.1 × 7.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLong Glass Plate\u003c\/td\u003e\n\u003ctd\u003e10.1 × 8.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHand-cast Gel Size\u003c\/td\u003e\n\u003ctd\u003e8.3 × 7.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecast Gel Size\u003c\/td\u003e\n\u003ctd\u003e8.6 × 6.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection id=\"features\"\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible one-to-four-gel operation:\u003c\/strong\u003e Select between one and four gels according to the experimental workload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecast and hand-cast gel support:\u003c\/strong\u003e The mini vertical electrophoresis cell accommodates both gel formats.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecast gel compatibility:\u003c\/strong\u003e Designed for compatibility with domestic and international brands of precast gel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlass-plate alignment:\u003c\/strong\u003e The edge cushion fixed to the long glass plate supports accurate alignment and helps reduce gel leakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCam-lock clamping frame:\u003c\/strong\u003e The rubber frame is designed for convenient operation and accurate glass-plate alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolymerization-compatible combs:\u003c\/strong\u003e Special plastic well combs do not inhibit gel polymerization, and their built-in ridges support uniform polymerization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-purity platinum electrode wire:\u003c\/strong\u003e The electrode wire supports conductive performance during electrophoresis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample-loading guide:\u003c\/strong\u003e The guide helps reduce missed lanes and repeated sample loading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection id=\"application\"\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeparation, purification and preparation of protein samples.\u003c\/li\u003e\n\u003cli\u003eAnalytical protein electrophoresis and protein purity identification.\u003c\/li\u003e\n\u003cli\u003eAnalysis of complex protein samples.\u003c\/li\u003e\n\u003cli\u003eSeparation, purification and preparation of nucleic acid samples.\u003c\/li\u003e\n\u003cli\u003eNucleic acid electrophoresis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection id=\"faq\"\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cdiv class=\"biofargo-faq\"\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is a mini four gel vertical electrophoresis tank used for?\u003c\/summary\u003e\n\u003cp\u003eIt is used for the separation, purification and preparation of protein and nucleic acid samples. It also supports analytical protein electrophoresis, protein purity identification, complex protein sample analysis and nucleic acid electrophoresis.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow many gels can the vertical electrophoresis system run?\u003c\/summary\u003e\n\u003cp\u003eThe system can accommodate between one and four gels according to the experimental requirement.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the electrophoresis tank support precast and hand-cast gels?\u003c\/summary\u003e\n\u003cp\u003eYes. The system supports hand-cast gels measuring 8.3 × 7.3 cm and precast gels measuring 8.6 × 6.8 cm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat gel thickness is supplied as standard?\u003c\/summary\u003e\n\u003cp\u003eThe standard gel thickness is 1.0 mm. Components for 0.75 mm and 1.5 mm gel thicknesses are available as optional configurations.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat comb configurations are available?\u003c\/summary\u003e\n\u003cp\u003eThe standard configuration uses a 1.0 mm 10-well comb. Optional configurations include 0.75 mm, 1.0 mm and 1.5 mm combs with 10-well or 15-well formats.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow does the sample-loading guide assist gel electrophoresis?\u003c\/summary\u003e\n\u003cp\u003eThe sample-loading guide helps direct sample loading and reduces the possibility of missing a lane or loading the same lane repeatedly.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/article\u003e","brand":"ZKYY","offers":[{"title":"Default Title","offer_id":53264009035957,"sku":"BF-VT04","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/mini-four-gel-vertical-electrophoresis-tank.jpg?v=1789378628","url":"https:\/\/biofargo.com\/products\/mini-four-gel-vertical-electrophoresis-tank","provider":"Biofargo","version":"1.0","type":"link"}