{"product_id":"ids-i10-and-ids-isys","title":"IDS-i10 and IDS-iSYS","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eIDS-i10\u003c\/strong\u003e and \u003cstrong\u003eIDS-iSYS Multi-Discipline Automated System\u003c\/strong\u003e are compact random access instruments for automated processing of chemiluminescence immunoassays (ChLIA) used in autoimmune, allergy, and infection diagnostics, as well as antigen detection. Continuous sample loading, and for the IDS-i10 also connection to a lab track system, allows each patient sample to be processed individually with minimal effort and short reaction times.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003ePreferred processing of emergency (STAT) samples gives laboratories with different requirements and sample volumes a high degree of flexibility in routine operation.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eRandom access instruments for batch, continuous, and STAT loading\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eMinimal calibration effort due to stored master curves\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConnection to a laboratory track system possible for the IDS-i10\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutoimmune, allergy, infection parameters, and antigen detection on one instrument\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eShort reaction times for fast and reliable results in just 25 minutes, depending on the test\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh throughput of up to 120 samples per hour\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConvenient and reliable operation through barcode recognition of samples and test- and lot-specific information, including stored standard curve\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Material\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSerum, plasma, urine or saliva (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eNumber of Loading Positions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e120 positions for samples, calibrators and controls (6 racks with 20 positions)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eNumber of Parameters\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 15 different immunoassay cartridges\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTime to First Result\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026lt; 25 minutes (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 120 tests\/hour (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePrimary tubes: 4.5 mL, 6 mL, 8.5 mL, 10 mL; secondary tubes: 5 mL; microvials: 500 μL, 2 mL\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eLuminometer\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eWavelengths from 300 to 500 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSpectrophotometer\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSpectrophotometer with LED technology and 12 wavelength filters\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volumes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4 μL – 300 μL (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIntegrated reader in sample compartment as well as for reagent cartridge barcodes\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM interface, bi-directional\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1050 × 750 × 700 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e103 kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eRandom Access Flexibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports batch, continuous, and STAT loading for efficient handling of routine and urgent samples.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFast Turnaround Time\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eDelivers results in less than 25 minutes, depending on the assay, for rapid clinical decisions.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh Throughput Performance\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProcesses up to 120 tests per hour for medium- to high-volume laboratories.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMulti-Discipline Testing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports autoimmune, allergy, infection diagnostics, and antigen detection on a single platform.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMinimal Calibration Effort\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eStored master calibration curves reduce setup time and improve consistency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated barcode recognition for samples and reagents ensures workflow security and data integrity.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eContinuous Sample Loading\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports uninterrupted workflow, with optional lab track integration for the IDS-i10.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWide Sample Compatibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports serum, plasma, urine, and saliva depending on the assay requirements.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePrecision Optical System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEquipped with a luminometer and LED-based spectrophotometer for reliable signal detection.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Pipetting Range\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eHandles volumes from 4 μL to 300 μL for broad assay versatility.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunodiagnostics:\u003c\/strong\u003e Detection of autoimmune diseases through chemiluminescence immunoassays.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Testing:\u003c\/strong\u003e Quantitative and qualitative analysis of allergy-related biomarkers.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Diagnostics:\u003c\/strong\u003e Identification of infectious agents and immune responses in clinical samples.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAntigen Detection:\u003c\/strong\u003e Rapid screening and monitoring of disease-specific antigens.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eRoutine Laboratory Automation:\u003c\/strong\u003e Ideal for laboratories requiring continuous, high-throughput immunoassay processing.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eSTAT Sample Processing:\u003c\/strong\u003e Prioritized testing for emergency samples in hospital and clinical laboratory environments.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375872405685,"sku":"IDS-ANA-I10ISYS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/IDS-i10_and_IDS-iSYS.jpg?v=1774245092","url":"https:\/\/biofargo.com\/products\/ids-i10-and-ids-isys","provider":"Biofargo","version":"1.0","type":"link"}