{"product_id":"hr1800-iia2-n-class-ii-a2-biosafety-cabinet","title":"NSF Series Biological Safety Cabinet - HAIer","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- =========================\nDESCRIPTION\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px; border-bottom: 2px solid #eee; padding-bottom: 20px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 20px; font-size: 24px;\"\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eMaintaining a stable and controlled environment is critical for sensitive biological workflows such as cell culture, biopharmaceutical research, and advanced life science applications. Variations in airflow performance, insufficient filtration efficiency, or inconsistent protection levels may affect sample integrity and laboratory safety during daily operations.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eHR1800-IIA2-N Class II Type A2 Biological Safety Cabinet\u003c\/strong\u003e is a large-format \u003cstrong\u003eClass II A2 biosafety cabinet\u003c\/strong\u003e designed to provide reliable protection for products, personnel, and the surrounding laboratory environment. With a wide 1800 mm working area, ULPA U15 filtration, dual airflow sensors, and microprocessor-controlled airflow management, this laboratory biosafety cabinet supports demanding cell culture and biotechnology workflows.\u003c\/p\u003e\n\u003cp\u003eDesigned for modern research laboratories, the HR1800-IIA2-N combines uniform airflow distribution, low-noise dual DC centrifugal fans, and an ergonomic stainless steel workspace to improve operational comfort while maintaining consistent biosafety performance. The cabinet is suitable for applications requiring a \u003cstrong\u003ecell culture biosafety cabinet\u003c\/strong\u003e, including biopharmaceutical research, biotechnology laboratories, and advanced biological studies.\u003c\/p\u003e\n\u003cp\u003eThe N Series Class II Type A2 Biological Safety Cabinet is available with NSF\/ANSI 49 certified configurations and incorporates advanced monitoring functions for airflow velocity, filter service life, operational status, and alarm conditions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nSPECIFICATION\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 25px; font-size: 24px;\"\u003eSpecification\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; border: 1px solid #999; border-radius: 4px;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; table-layout: fixed; min-width: 980px; font-size: 14px; color: #222;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"background: #0056a6; color: #fff; font-weight: bold; border: 1px solid #999; text-align: center;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"background: #0056a6; color: #fff; font-weight: bold; border: 1px solid #999; text-align: center;\"\u003eHR1800-IIA2-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"8\" style=\"background: #f2f7ff; color: #1d5fbf; font-weight: bold; font-size: 16px; vertical-align: middle; border: 1px solid #999; text-align: center;\"\u003eGeneral Specifications\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eCabinet Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eClass II Type A2 Biological Safety Cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eWorking Voltage \u0026amp; Frequency\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e100~230 V \/ 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eNominal Power Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e440 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eHeat Load\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e1500 BTU\/Hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eAirflow Circulation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e70% Downflow \/ 30% Exhaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eMain Filter Efficiency\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eULPA U15, 99.9995% @ 0.12 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eExhaust Filter Efficiency\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eULPA U15, 99.9995% @ 0.12 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eFilter Brand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eAAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"7\" style=\"background: #f2f7ff; color: #1d5fbf; font-weight: bold; font-size: 16px; vertical-align: middle; border: 1px solid #999; text-align: center;\"\u003ePerformance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eDownflow Velocity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e0.35 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eInflow Velocity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e0.53 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eInflow Volume\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e768 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eLighting Intensity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e1292 Lux\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eFan Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eDual DC Centrifugal Fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eFan Brand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eEBM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eSound Level\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e63 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" style=\"background: #f2f7ff; color: #1d5fbf; font-weight: bold; font-size: 16px; vertical-align: middle; border: 1px solid #999; text-align: center;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eInternal Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e1830 × 600 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eExternal Dimensions (W×D×H)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e2038 × 945 × 1700 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eSash Opening\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e200 mm (Maximum 460 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eSupport Stand\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e680 mm Standard \/ 680-900 mm Adjustable Optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eWork Surface\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eOne-piece 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" style=\"background: #f2f7ff; color: #1d5fbf; font-weight: bold; font-size: 16px; vertical-align: middle; border: 1px solid #999; text-align: center;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eUL NSF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eAirflow Sensors\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eDual Wind Speed Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eControl System\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003eMicroprocessor Controlled Airflow System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #999; padding: 8px 12px; text-align: center;\"\u003eUV Timer Function\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #999; text-align: center;\"\u003e0-24 Hours Automatic On\/Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nFEATURES\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 25px; font-size: 24px;\"\u003eFeatures\u003c\/h2\u003e\n\u003cul style=\"list-style: none; padding: 0; margin: 0; display: grid; grid-template-columns: repeat(auto-fit,minmax(300px,1fr)); gap: 20px;\"\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eULPA U15 Filtration System\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eThe HR1800-IIA2-N uses ULPA U15 filters with 99.9995% efficiency at 0.12 μm to provide high cleanliness airflow for demanding biological workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eDual Airflow Sensor Monitoring\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eDual wind speed sensors continuously monitor working area airflow and exhaust airflow, allowing automatic adjustment through the microprocessor control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eMicroprocessor Controlled Airflow\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eReal-time airflow monitoring helps maintain stable downflow and inflow performance during laboratory operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eLarge Cell Culture Workspace\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eThe 1800 mm wide working area provides additional space for cell culture vessels, instruments, and biological sample handling workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eLow Noise Dual DC Fans\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eIndependent dual DC centrifugal fans deliver uniform airflow distribution with improved energy efficiency and reduced operating noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli style=\"background: #fdfdfd; border: 1px solid #eee; padding: 20px; border-radius: 8px;\"\u003e\n\u003cp style=\"font-size: 18px; color: #0056a6; font-weight: bold; margin: 0 0 8px;\"\u003eEasy-to-Clean Stainless Steel Interior\u003c\/p\u003e\n\u003cp style=\"margin: 0; font-size: 14px;\"\u003eThe one-piece stainless steel liner and 304 stainless steel work surface minimize cleaning dead zones and simplify maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nAPPLICATIONS\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 20px; font-size: 24px;\"\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eThe HR1800-IIA2-N Class II Type A2 Biological Safety Cabinet is designed for laboratories requiring reliable personnel, product, and environmental protection during biological workflows.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCell Culture Research:\u003c\/strong\u003e Suitable for mammalian cell culture, stem cell research, and routine biological sample handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBiopharmaceutical Development:\u003c\/strong\u003e Supports research laboratories involved in biologics development and process research.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBiotechnology Laboratories:\u003c\/strong\u003e Provides controlled airflow protection for advanced life science applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAcademic Research Facilities:\u003c\/strong\u003e Suitable for universities and research institutes conducting biological studies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMolecular Biology Workflows:\u003c\/strong\u003e Supports sensitive sample preparation and contamination-controlled procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLife Science Laboratories:\u003c\/strong\u003e Designed for general biological research requiring a Class II A2 biosafety cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\n\u003c!-- =========================\nDOCUMENTS\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 20px; font-size: 24px;\"\u003eDocuments\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 15px;\"\u003e\n  \u003c!-- Product Brochure Placeholder --\u003e\n\u003cdiv style=\"border: 1px solid #e1e1e1; border-radius: 8px; padding: 15px; background: #fff; display: flex; flex-direction: column; justify-content: space-between; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"\u003e\n\u003cp style=\"margin: 0 0 15px 0; font-weight: bold; color: #444; font-size: 15px;\"\u003eProduct Brochure\u003c\/p\u003e\n\u003ca style=\"background: #0056a6; color: #fff; text-decoration: none; text-align: center; padding: 10px; border-radius: 4px; font-size: 13px; font-weight: bold; display: flex; align-items: center; justify-content: center;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Laboratory_Protection_Clean_Air_Solutions_31-10-2025_806c72aa-d19f-4052-9ba6-5ca0dc449ad2.pdf?v=1783686828\"\u003e \u003cspan style=\"margin-right: 8px;\"\u003e▼\u003c\/span\u003e DOWNLOAD PDF \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c!-- Flyer Placeholder --\u003e\n\u003cdiv style=\"border: 1px solid #e1e1e1; border-radius: 8px; padding: 15px; background: #fff; display: flex; flex-direction: column; justify-content: space-between; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"\u003e\n\u003cp style=\"margin: 0 0 15px 0; font-weight: bold; color: #444; font-size: 15px;\"\u003eProduct  Flyer\u003c\/p\u003e\n\u003ca style=\"background: #0056a6; color: #fff; text-decoration: none; text-align: center; padding: 10px; border-radius: 4px; font-size: 13px; font-weight: bold; display: flex; align-items: center; justify-content: center;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/NSF_N_20Series_20Class_20II_20Type_20A2_20Biological_20Safety_20Cabinet_20HR900-IIA2-N_20HR1200-IIA2-N_20HR1500-IIA2-N_20HR1800-IIA2-N.pdf?v=1783687000\"\u003e \u003cspan style=\"margin-right: 8px;\"\u003e▼\u003c\/span\u003e DOWNLOAD PDF \u003c\/a\u003e\n\u003c\/div\u003e\n  \n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nCERTIFICATIONS\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 20px; font-size: 24px;\"\u003eCertifications\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit,minmax(280px,1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"border: 1px solid #e1e1e1; border-radius: 8px; padding: 15px; background: #fff; display: flex; flex-direction: column; justify-content: space-between; box-shadow: 0 2px 4px rgba(0,0,0,0.05);\"\u003e\n\u003cp style=\"margin: 0 0 15px 0; font-weight: bold; color: #444; font-size: 15px;\"\u003eCertification Documents\u003c\/p\u003e\n\u003ca style=\"background: #0056a6; color: #fff; text-decoration: none; text-align: center; padding: 10px; border-radius: 4px; font-size: 13px; font-weight: bold; display: flex; align-items: center; justify-content: center;\" href=\"https:\/\/biofargo.com\/pages\/contact-us\"\u003e \u003cspan style=\"margin-right: 8px;\"\u003e▼\u003c\/span\u003e ASK FOR CERTIFICATIONS \u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nFAQ\n========================= --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\"color: #0056a6; padding-left: 15px; margin-bottom: 20px; font-size: 24px;\"\u003eFAQ\u003c\/h2\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eWhat is a Class II Type A2 Biological Safety Cabinet?\u003c\/summary\u003e\n\u003cp\u003eA Class II Type A2 Biological Safety Cabinet is a laboratory safety enclosure designed to provide protection for the operator, product, and environment through controlled airflow and high-efficiency filtration. It is commonly used for cell culture, biotechnology research, and biological laboratory applications.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eWhat applications is the HR1800-IIA2-N biosafety cabinet suitable for?\u003c\/summary\u003e\n\u003cp\u003eThe HR1800-IIA2-N is suitable for cell culture laboratories, biopharmaceutical research, biotechnology applications, academic research facilities, and other life science workflows requiring a Class II A2 biosafety cabinet.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eWhat is the difference between a Class II A2 biosafety cabinet and a laminar flow hood?\u003c\/summary\u003e\n\u003cp\u003eA Class II A2 biosafety cabinet provides protection for personnel, products, and the environment through controlled inward airflow and filtered exhaust. A laminar flow hood mainly protects the sample and does not provide the same level of operator and environmental protection.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eWhy does the HR1800-IIA2-N use ULPA U15 filtration?\u003c\/summary\u003e\n\u003cp\u003eThe HR1800-IIA2-N uses ULPA U15 filters with a typical efficiency of 99.9995% at 0.12 μm. The filtration system helps maintain high cleanliness airflow for sensitive biological laboratory procedures.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eHow does the airflow control system maintain cabinet performance?\u003c\/summary\u003e\n\u003cp\u003eThe HR1800-IIA2-N uses dual wind speed sensors and a microprocessor control system to monitor airflow conditions in real time. The system automatically adjusts fan speed to help maintain stable airflow performance.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eIs the HR1800-IIA2-N suitable for large-scale cell culture workflows?\u003c\/summary\u003e\n\u003cp\u003eYes. With an 1800 mm wide working area, the HR1800-IIA2-N provides additional workspace for cell culture vessels, laboratory equipment, and biological sample handling workflows.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border: 1px solid #ddd; padding: 15px; margin-bottom: 10px; border-radius: 6px;\"\u003e\n\u003csummary style=\"font-weight: bold; color: #0056a6; cursor: pointer;\"\u003eWhat type of filter is used in the HR1800-IIA2-N Biological Safety Cabinet?\u003c\/summary\u003e\n\u003cp\u003eThe cabinet uses ULPA U15 filters for both supply and exhaust filtration. The typical filtration efficiency is 99.9995% at 0.12 μm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/section\u003e\n\u003c!-- =========================\nPRODUCT SCHEMA\n========================= --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- =========================\nFAQ SCHEMA\n========================= --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Haier Biomedical","offers":[{"title":"Default Title","offer_id":52785539645621,"sku":"HR1800-IIA2-N","price":14700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/3_649a2f70-7959-4f52-a099-3c85244a3e2d.jpg?v=1783686750","url":"https:\/\/biofargo.com\/products\/hr1800-iia2-n-class-ii-a2-biosafety-cabinet","provider":"Biofargo","version":"1.0","type":"link"}