{"product_id":"eurostar-iii-plus-controlled-light-intensity-for-reliable-ifa-diagnostics","title":"EUROStar III Plus LED Fluorescence Microscope – Controlled Light Intensity for Reproducible IFA Imaging","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eEUROStar III Plus\u003c\/strong\u003e LED fluorescence microscope is specifically designed for indirect immunofluorescence applications. A camera can be directly connected to the integrated photo tube for seamless digital image acquisition, while a 50\/50 beam splitter enables simultaneous viewing through ocular and camera without switching.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe system supports digital image capture and analysis via EUROPicture software. An optional immunofluorescence positioning system (IF-PS) minimizes positioning errors and improves result accuracy.\u003c\/p\u003e\n\u003cp\u003eEquipped with a halogen lamp for transmitted light microscopy (bright and dark field) and upgrade capability for phase contrast, the microscope offers flexible functionality for diverse laboratory applications.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eRegulated LED ensures constant fluorescence excitation for reproducible results\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eLong lifespan exceeding 50,000 hours with low power consumption\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eMercury-free design for environmentally friendly operation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDigital imaging with optional camera and EUROPicture software\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e50\/50 beam splitter enables simultaneous ocular and camera observation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Specifications --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eLED Light Source (Excitation)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e460–490 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Life\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eMinimum 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e7.36 × 16.14 × 17.68 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e21.16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStable LED Excitation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eRegulated 460–490 nm LED ensures consistent fluorescence intensity and reproducible results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUltra-Long Lifespan\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eOver 50,000 hours of operation reduces maintenance and eliminates frequent lamp replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eInstant Illumination\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eProvides full light intensity immediately after startup with low energy consumption.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMercury-Free Design\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eEnvironmentally friendly system without hazardous mercury lamps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDigital Imaging Integration\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eDirect camera connection enables seamless image capture and analysis with EUROPicture software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003e50\/50 Beam Splitter\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eAllows simultaneous viewing through ocular and camera without switching.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIF Positioning System (Optional)\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eReduces positioning errors and improves accuracy in microscopy result documentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDual-Mode Microscopy\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eIncludes halogen lamp for bright and dark field microscopy with upgrade capability for phase contrast.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eIFA Analysis:\u003c\/strong\u003e Visualization of antibody-antigen interactions in immunofluorescence assays.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAutoimmune Research:\u003c\/strong\u003e \u003cstrong\u003eIdentification\u003c\/strong\u003e and analysis of ANA, ANCA, and related fluorescence patterns.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eLaboratory Imaging:\u003c\/strong\u003e Routine fluorescence microscopy with reliable and standardized image acquisition.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eDigital Documentation:\u003c\/strong\u003e Image capture, storage, and analysis using EUROPicture software.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCell \u0026amp; Tissue Analysis:\u003c\/strong\u003e Observation of fluorescently labeled cells, tissues, and substrates.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eEducation \u0026amp; Training:\u003c\/strong\u003e Ideal for teaching fluorescence microscopy with real-time digital visualization.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375769809077,"sku":"EU-MIC-ES3P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROStar_III_Plus_Controlled_Light_Intensity_for_Reliable_IFA_Diagnostics.jpg?v=1774232908","url":"https:\/\/biofargo.com\/products\/eurostar-iii-plus-controlled-light-intensity-for-reliable-ifa-diagnostics","provider":"Biofargo","version":"1.0","type":"link"}