{"product_id":"europattern-microscope-for-in-vitro-diagnostic-use","title":"EUROPattern Microscope Computer-aided Immunofluorescence Microscopy (CAIFM)","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROPattern Suite\u003c\/strong\u003e automates immunofluorescence microscopy, enhancing diagnostic result reporting and seamlessly integrating with EUROLabOffice for flexible laboratory workflows.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eDesigned for high-throughput environments, the system minimizes manual handling and enables standardized IFA diagnostics with exceptional speed and efficiency.\u003c\/p\u003e\n            \u003cp\u003eThe suite combines a fully automated microscope with a slide magazine (up to 500 substrate fields per run) and advanced pattern recognition software for accurate classification and evaluation.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated microscopy with on-screen reporting system, eliminating the need for a darkroom\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003ePattern recognition and titer determination for multiple substrates\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eExtended walk-away time with automated processing of up to 500 positions per run\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh-throughput imaging with over 250 fluorescence images evaluated per hour\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable traceability through automatic slide identification via matrix codes\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003ePower Supply\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e110–240 V, 60 W, 50\/60 Hz\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eLED Light Source (Constant)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e620–630 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ecLED Light Source (Constant Excitation)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e460–490 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e20.08 × 25.98 × 33.46 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e180.78 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Microscopy\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomates the entire IFA imaging workflow, eliminating manual microscopy and removing the need for a darkroom.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePattern Recognition \u0026amp; Titer Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eIntegrated software enables automatic fluorescence pattern classification and quantitative titer determination.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh-Throughput Imaging\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eCaptures and evaluates over 250 fluorescence images per hour for efficient large-scale diagnostics.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLarge Capacity Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses up to 500 substrate fields per run, enabling extended walk-away automation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eSoftware Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSeamlessly integrates with EUROLabOffice for flexible data management and reporting workflows.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eTraceability \u0026amp; Reliability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomatic slide identification via matrix codes ensures full traceability and reduces human error.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReproducible Results\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eMinimizes manual variability, delivering consistent and standardized immunofluorescence diagnostics.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Detection and classification of autoantibodies using IFA (e.g., ANA, ANCA).\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunology Laboratories:\u003c\/strong\u003e High-throughput routine screening and confirmation of fluorescence-based tests.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eIn Vitro Diagnostic (IVD) Workflows:\u003c\/strong\u003e Standardized automated microscopy for regulated diagnostic environments.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e Evaluation of antibody responses using fluorescence-based assays.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e Integration into LIS for automated interpretation, reporting, and data management.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch \u0026amp; Translational Studies:\u003c\/strong\u003e Fluorescence pattern analysis and antibody profiling in immunology research.\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375743955125,"sku":"EU-MIC-EPML","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROPattern_Microscope_for_In_Vitro_Diagnostic_Use.jpg?v=1774231335","url":"https:\/\/biofargo.com\/products\/europattern-microscope-for-in-vitro-diagnostic-use","provider":"Biofargo","version":"1.0","type":"link"}