{"product_id":"eurolabworkstation-ifa-for-in-vitro-diagnostic-use","title":"EUROLabWorkstation IFA Full Automation of Indirect Immunofluorescence","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n    \n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROLabWorkstation IFA\u003c\/strong\u003e heralds a new era in IFA automation. With this new development EUROIMMUN enables fully automated and standardized processing with highest capacity and highest efficiency for laboratories with high sample throughput. Up to 750 substrate fields and more than 700 samples can be analyzed at high throughput with just one worklist. The system was developed by EUROIMMUN with a focus on data integrity and minimisation of manual processes. This ensures brilliant fluorescence signals without background for the automatically mounted slides.\u003c\/p\u003e\n            \u003cp\u003eThe software can be operated comfortably and intuitively via a touch screen and guides the user through the entire process. Complete traceability is guaranteed at all times, since the matrix codes of the slides and the barcodes of samples, reagents and accessories are automatically detected in each step of the process.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated processing of EUROIMMUN immunofluorescence tests from primary sample to mounted slide\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHighest capacity of up to 750 substrate fields and more than 700 samples in a single worklist\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHighest efficiency due to 10 washable pipetting needles and complementary accessories, as well as separation of pipetting and transport steps for flexible time management\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible workflows owing to freely selectable loading of the 45 tracks with samples, reagents and dilution plates\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eBrilliant fluorescence signals – each substrate field is washed without the risk of cross contamination using directed liquid flow in a standardised and gentle procedure\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum, CSF, and DBS\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 700 samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 750 reaction fields (combination of slides with 10 and 50 reaction fields possible)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eParameter Capacity per Run\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 75\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Washing Unit\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOne each for slides with 10 and 50 reaction fields\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eReagent Tray Washing Unit\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 dispensing needles and 11 aspiration needles\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 200 tests per hour\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volume\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 μl – 1100 μl, 1 μl increments\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eAutomated registration of samples, reagents, dilution plates, slides, reagent trays and cover glass holders\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eTouchscreen PC with EUROLabWorkstation IFA software\u003cbr\u003eMicrosoft® Windows® 10 LTSB\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM via EUROLabOffice\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e114.96 × 31.93 × 33.82 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e992.08 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWorkflow optimization\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e45 sample and reagent tracks for freely selectable loading | Slides with 10 and 50 reaction fields | Spatial separation of liquid handling and incubation | Fully automated washing and mounting.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_576a7ac2-8a55-4962-b952-def1a1a0c207.jpg?v=1774228471\" alt=\"Workflow Optimization\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePrecise \u0026amp; Efficient Pipetting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e10 coated stainless steel needles | Precision pumps | Optimised routes | Liquid level detection | Multishot function for reagents.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features02.jpg?v=1774228471\" alt=\"Pipetting Efficiency\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eInnovative Washing Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eControlled liquid flow | Two integrated washing units | Reagent tray cleaning | Automatic mounting medium dispensing.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features03.jpg?v=1774228471\" alt=\"Washing Technology\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eConvenient Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eTouch-screen PC | Intuitive GUI | Real-time flow display | Software-supported maintenance.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features04.jpg?v=1774228471\" alt=\"Operation\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n          \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eProcess Status Overview\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eDetailed status on run times, resources and slides; ID-based memory; Exact pending time.\u003c\/p\u003e\n        \n            \u003c\/div\u003e\n          \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eProcess Security A-Z\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eMulti-user rights; Transparent traceability; Gapless allocation of samples and reagents.\u003c\/p\u003e\n        \n            \u003c\/div\u003e\n        \u003c\/div\u003e\n\n       \n  \n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"column-count: 1; gap: 30px;\"\u003e\n            \u003cp style=\"margin-bottom: 20px; font-style: italic;\"\u003eThe EUROLabWorkstation IFA is designed for fully automated indirect immunofluorescence (IFA) workflows in high-throughput environments...\u003c\/p\u003e\n            \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Automated detection of ANA, ANCA, anti-dsDNA.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e High-throughput viral and bacterial screening.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical Routine Testing:\u003c\/strong\u003e Improved turnaround for hospital diagnostic labs.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eReference Laboratories:\u003c\/strong\u003e Standardized workflows \u0026amp; LIS integration.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eResearch \u0026amp; Translational:\u003c\/strong\u003e Large-scale immunological studies.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eEpidemiological Surveillance:\u003c\/strong\u003e Rapid population-level antibody screening.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e End-to-end processing with minimal human error.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Platforms:\u003c\/strong\u003e \u0026gt;200 tests per hour capacity.\u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375729864885,"sku":"EU-LAB-ELWIF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROLabWorkstation_IFA_for_In_Vitro_Diagnostic_Use.jpg?v=1774228832","url":"https:\/\/biofargo.com\/products\/eurolabworkstation-ifa-for-in-vitro-diagnostic-use","provider":"Biofargo","version":"1.0","type":"link"}