{"product_id":"euroblot-one-automated-immunoblot-workstation-solution","title":"EUROBlot One Automated Immunoblot Workstation Solution","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROBlotOne\u003c\/strong\u003e is a compact tabletop device for complete immunoblot processing. After fast, software-guided loading, the system performs sample identification and dilution, as well as all incubation and wash steps automatically.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eEight reagent channels allow combined testing from autoimmune and infection diagnostics in one run, as well as allergy testing on the same device. Incubated strips are automatically dried, photographed, and evaluated using EUROLineScan software.\u003c\/p\u003e\n            \u003cp\u003eTest requests and results can be communicated bidirectionally with an LIS or EUROLabOffice 4.0 for seamless laboratory integration.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated processing of up to 44 immunoblots in one run, from sample identification to final result\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eIntegrated drying unit for fast strip evaluation and high reproducibility\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh security through automatic barcode identification of samples\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible combination of autoimmune and infection parameters in one run, with autoimmune, infection, and allergy diagnostics on one device\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eIntuitive software for secure and convenient operation\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable automated blot strip evaluation using EUROLineScan software\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum and CSF\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePatient Sample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 44\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eControl Positions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTest Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e44 strips\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 8–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIntegrated code scanner for identification of samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eMicrosoft® Windows® 10 Pro\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eBi-directional via EUROLineScan\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e318.90 × 20.87 × 19.49 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e88.18 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Workflow\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnd-to-end automation from sample identification to final result for up to 44 immunoblot strips per run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Drying System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBuilt-in drying unit enables rapid strip processing and highly reproducible results.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic barcode scanning ensures secure sample identification and reduces manual errors.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMultiplex Testing Flexibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports combined autoimmune, infection, and allergy assays on a single device.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntelligent Software Control\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSoftware-guided operation provides secure, intuitive, and convenient workflow management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated Imaging \u0026amp; Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBlot strips are automatically photographed and evaluated with EUROLineScan software.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Connectivity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBi-directional communication with LIS or EUROLabOffice supports seamless laboratory integration.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Detection of autoantibodies for ANA, ENA, and other autoimmune markers.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Identification of pathogen-specific antibodies for viral, bacterial, and parasitic infections.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Diagnostics:\u003c\/strong\u003e Multiparametric analysis of allergen-specific antibodies in clinical samples.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunology Laboratories:\u003c\/strong\u003e Ideal for routine immunoblot processing with medium throughput requirements.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eReference \u0026amp; Diagnostic Labs:\u003c\/strong\u003e Automated immunoblot workflows for improved reproducibility and efficiency.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Applications:\u003c\/strong\u003e Suitable for immunoblot-based biomarker studies and assay development.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375916708021,"sku":"EU-LAB-BLO1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROBlot_One_Automated_Immunoblot_Workstation_Solution.jpg?v=1774245924","url":"https:\/\/biofargo.com\/products\/euroblot-one-automated-immunoblot-workstation-solution","provider":"Biofargo","version":"1.0","type":"link"}