{"product_id":"car-tcr-transgene-copy-number-quantitation-kit","title":"CAR\/TCR Transgene Copy Number Quantitation Kit SHENTEK®","description":"\u003cstyle type=\"text\/css\"\u003e\n.shentek-wrapper {\n    font-family: 'Segoe UI', Roboto, Helvetica, Arial, sans-serif;\n    color: #2c3e50;\n    line-height: 1.7;\n    margin: 0 auto;\n    background: #fff;\n    padding: 10px;\n}\n\n.shentek-header-bar {\n    background-color: #0056b3;\n    border-radius: 8px;\n    padding: 20px;\n    display: flex;\n    flex-wrap: wrap;\n    justify-content: space-around;\n    align-items: center;\n    color: #ffffff;\n    margin-bottom: 30px;\n    box-shadow: 0 4px 6px rgba(0, 0, 0, 0.1);\n}\n\n.shentek-header-item {\n    text-align: center;\n    padding: 10px;\n    min-width: 200px;\n}\n\n.shentek-header-item--bordered {\n    \n    border-right: 1px solid rgba(255, 255, 255, 0.2);\n}\n\n.shentek-header-label {\n    font-size: 14px;\n    opacity: 0.9;\n    margin-bottom: 5px;\n}\n\n.shentek-header-value {\n    font-size: 18px;\n    font-weight: bold;\n}\n\n.shentek-section {\n    margin-bottom: 45px;\n}\n\n.shentek-section--divider {\n    border-bottom: 2px solid #f0f4f8;\n    padding-bottom: 25px;\n    margin-bottom: 40px;\n}\n\n.shentek-section--card {\n    background: #fcfdfe;\n    border: 1px solid #d1d5db;\n    border-radius: 12px;\n    padding: 30px;\n}\n\n.shentek-title {\n    color: #0056b3;\n    font-size: 24px;\n    margin-top: 0;\n    display: flex;\n    align-items: center;\n}\n\n.shentek-title-bar {\n    background: #0056b3;\n    width: 4px;\n    height: 24px;\n    margin-right: 12px;\n    display: inline-block;\n}\n\n.shentek-subtitle {\n    color: #2d3748;\n    font-size: 20px;\n    margin-bottom: 20px;\n}\n\n.shentek-subtitle--bar {\n    \n    padding-left: 15px;\n    margin-bottom: 25px;\n}\n\n.shentek-subtitle--icon {\n    margin-top: 0;\n    display: flex;\n    align-items: center;\n}\n\n.shentek-subtitle-icon {\n    margin-right: 12px;\n}\n\n.shentek-heading {\n    color: #2d3748;\n    font-size: 18px;\n    \n    padding-left: 12px;\n    margin-bottom: 15px;\n}\n\n.shentek-text {\n    font-size: 16px;\n    color: #4a5568;\n    margin-top: 15px;\n}\n\n.shentek-table-wrapper {\n    overflow-x: auto;\n}\n\n.shentek-table {\n    width: 100%;\n    border-collapse: collapse;\n    border: 1px solid #e2e8f0;\n    font-size: 15px;\n}\n\n.shentek-table thead tr {\n    background-color: #0056b3;\n    color: #fff;\n    text-align: left;\n}\n\n.shentek-table th {\n    padding: 15px;\n}\n\n.shentek-table td {\n    padding: 12px 15px;\n    border-bottom: 1px solid #e2e8f0;\n}\n\n.shentek-table td:first-child {\n    font-weight: 600;\n    background: #f8fafc;\n}\n\n.shentek-table .shentek-text-danger {\n    color: #c53030;\n    font-weight: 600;\n}\n\n.shentek-grid {\n    display: grid;\n    gap: 30px;\n}\n\n.shentek-grid--2col {\n    grid-template-columns: repeat(auto-fit, minmax(450px, 1fr));\n}\n\n.shentek-grid--4col {\n    grid-template-columns: repeat(auto-fit, minmax(240px, 1fr));\n    gap: 20px;\n}\n\n.shentek-grid--downloads {\n    grid-template-columns: repeat(auto-fit, minmax(300px, 1fr));\n    gap: 15px;\n}\n\n.shentek-list {\n    padding-left: 20px;\n    font-size: 14.5px;\n    color: #4a5568;\n}\n\n.shentek-list li {\n    margin-bottom: 8px;\n}\n\n.shentek-list li:last-child {\n    margin-bottom: 0;\n}\n\n.shentek-box {\n    background: #f8fafc;\n    padding: 15px;\n    border-radius: 6px;\n    font-size: 13.5px;\n    color: #4a5568;\n    border: 1px solid #e2e8f0;\n}\n\n.shentek-box-row {\n    display: flex;\n    justify-content: space-between;\n    padding: 6px 0;\n    border-bottom: 1px dashed #cbd5e1;\n}\n\n.shentek-box-note {\n    margin-top: 10px;\n    font-size: 12px;\n    color: #64748b;\n    font-style: italic;\n}\n\n.shentek-box--warning {\n    background: #fff5f5;\n    border: 1px solid #feb2b2;\n    color: #c53030;\n}\n\n.shentek-box--warning p {\n    margin: 0;\n}\n\n.shentek-box--warning p + p {\n    margin-top: 8px;\n}\n\n.shentek-card {\n    border: 1px solid #e2e8f0;\n    border-radius: 8px;\n    padding: 20px;\n    text-align: center;\n    background: #fff;\n}\n\n.shentek-card-title {\n    font-size: 14px;\n    margin: 0 0 15px 0;\n    height: 40px;\n    color: #2d3748;\n}\n\n.shentek-btn {\n    display: block;\n    padding: 8px;\n    background: #0056b3;\n    color: #fff;\n    text-decoration: none;\n    border-radius: 4px;\n    font-size: 13px;\n    font-weight: 600;\n}\n\n.shentek-download-link {\n    display: flex;\n    align-items: center;\n    background: #fff;\n    padding: 12px 18px;\n    border-radius: 6px;\n    border: 1px solid #cbd5e1;\n    text-decoration: none;\n    color: #334155;\n    font-size: 14px;\n    font-weight: 500;\n}\n\n.shentek-download-link .shentek-pdf-icon {\n    color: #ef4444;\n    font-weight: bold;\n    margin-right: 10px;\n}\n\n.shentek-download-link .shentek-arrow {\n    margin-left: auto;\n    color: #94a3b8;\n}\n\n.shentek-faq {\n    border: 1px solid #e2e8f0;\n    border-radius: 8px;\n    overflow: hidden;\n}\n\n.shentek-faq-item {\n    padding: 15px 20px;\n    border-bottom: 1px solid #e2e8f0;\n}\n\n.shentek-faq-item:last-child {\n    border-bottom: none;\n}\n\n.shentek-faq-item--alt {\n    background-color: #f8fafc;\n}\n\n.shentek-faq-question {\n    font-weight: bold;\n    color: #0056b3;\n    margin-bottom: 5px;\n}\n\n.shentek-faq-answer {\n    font-size: 14px;\n    color: #4a5568;\n}\n\n.shentek-notice {\n    background-color: #fffbeb;\n    border: 1px solid #fde68a;\n    border-radius: 8px;\n    padding: 20px;\n    margin-top: 30px;\n    margin-bottom: 30px;\n}\n\n.shentek-notice-header {\n    display: flex;\n    align-items: center;\n    gap: 8px;\n    margin-bottom: 12px;\n}\n\n.shentek-notice-icon {\n    width: 20px;\n    height: 20px;\n    color: #d97706;\n    flex-shrink: 0;\n}\n\n.shentek-notice-title {\n    font-weight: bold;\n    color: #78350f;\n    margin: 0;\n    font-size: 16px;\n}\n\n.shentek-notice-body {\n    margin-left: 28px;\n}\n\n.shentek-notice-item {\n    display: flex;\n    align-items: flex-start;\n    gap: 8px;\n    margin-bottom: 10px;\n}\n\n.shentek-notice-item:last-child {\n    margin-bottom: 0;\n}\n\n.shentek-notice-check {\n    color: #d97706;\n    font-weight: bold;\n    flex-shrink: 0;\n}\n\n.shentek-notice-text {\n    margin: 0;\n    font-size: 14px;\n    color: #374151;\n    line-height: 1.5;\n}\n\u003c\/style\u003e\n\n\u003cdiv class=\"shentek-wrapper\"\u003e\n    \u003cdiv class=\"shentek-header-bar\"\u003e\n        \u003cdiv class=\"shentek-header-item\"\u003e\n            \u003cdiv class=\"shentek-header-label\"\u003e Detection Method\u003c\/div\u003e\n            \u003cdiv class=\"shentek-header-value\"\u003eqPCR\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"shentek-header-item shentek-header-item--bordered\"\u003e\n            \u003cdiv class=\"shentek-header-label\"\u003e Assay Time\u003c\/div\u003e\n            \u003cdiv class=\"shentek-header-value\"\u003eRefer to manual\u003c\/div\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"shentek-header-item\"\u003e\n            \u003cdiv class=\"shentek-header-label\"\u003e Storage Temperature\u003c\/div\u003e\n            \u003cdiv class=\"shentek-header-value\"\u003e-20 °C (stable for 24 months)\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003csection class=\"shentek-section shentek-section--divider\"\u003e\n        \u003ch2 class=\"shentek-title\"\u003e\n            \n            Product Description\n        \u003c\/h2\u003e\n        \u003cp class=\"shentek-text\"\u003eSHENTEK® CAR\/TCR Transgene Copy Number Quantitation Kit is designed to quantify the copy number of target genes in human cell products derived from common HIV-1 lentiviral vectors (e.g., CAR or TCR genes integrated in CAR-T and TCR-T cell genomes). The kit uses a multiplex qPCR assay to detect DNA sequences related to the integration\/expression elements on the transfer plasmid and a Single Copy Gene (SCG) in human cells, enabling calculation of average copies of target gene per cell. The kit includes a company-produced reference standard and an internal positive control (IPC). The assay is intended for rapid, specific, reliable and universal lentiviral vector applications. For Research Use Only.\u003c\/p\u003e\n    \u003c\/section\u003e\n\n    \u003csection class=\"shentek-section\"\u003e\n        \u003ch3 class=\"shentek-subtitle\"\u003eTechnical Specifications\u003c\/h3\u003e\n        \u003cdiv class=\"shentek-table-wrapper\"\u003e\n            \u003ctable class=\"shentek-table\"\u003e\n                \u003cthead\u003e\n                    \u003ctr\u003e\n                        \u003cth\u003eParameter\u003c\/th\u003e\n                        \u003cth\u003eDetails\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eProduct number\u003c\/td\u003e\n                        \u003ctd\u003eSK030221CA100\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eIntended reactions\u003c\/td\u003e\n                        \u003ctd class=\"shentek-text-danger\"\u003eReagents for 100 reactions\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eReference standard initial concentration\u003c\/td\u003e\n                        \u003ctd class=\"shentek-text-danger\"\u003eCAR\/TCR Control initial copy number: 2.33 × 10^8 copies\/μL\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eStandard curve serial dilutions (copies\/μL)\u003c\/td\u003e\n                        \u003ctd\u003eST1: 2.33 × 10^6; ST2: 2.33 × 10^5; ST3: 2.33 × 10^4; ST4: 2.33 × 10^3; ST5: 2.33 × 10^2\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eReaction volume\u003c\/td\u003e\n                        \u003ctd\u003eTotal reaction volume 30 μL (20 μL qPCR MIX + 10 μL template)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eqPCR MIX composition (per reaction)\u003c\/td\u003e\n                        \u003ctd\u003eqPCR Reaction Buffer 15.9 μL; CAR\/TCR Primer \u0026amp; Probe MIX 2.8 μL; IPC MIX 1.3 μL (total 20 μL)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eThermal cycling program\u003c\/td\u003e\n                        \u003ctd\u003eActivation 95 °C 10:00 (1 cycle); Denaturation 95 °C 00:15 (40 cycles); Annealing\/Extension 60 °C 01:00 (fluorescence read)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eReporter dyes \/ targets\u003c\/td\u003e\n                        \u003ctd\u003eCAR\/TCR target: FAM; SCG: CY5; IPC: VIC; ROX as passive reference\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eCt \/ analysis settings\u003c\/td\u003e\n                        \u003ctd\u003eManual Ct threshold 0.02; Automatic baseline; verify slope\/intercept\/R² for standard curve\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eAcceptance criteria for IPC\u003c\/td\u003e\n                        \u003ctd\u003eMean Ct-IPC of sample should be within ±1.0 of the NCS Ct-IPC; significant increase indicates inhibition\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eRecommended DNA input per well\u003c\/td\u003e\n                        \u003ctd\u003eRecommended 5 ng to 30 ng total DNA per well (adjust based on preliminary experiments)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eCalculation formula\u003c\/td\u003e\n                        \u003ctd class=\"shentek-text-danger\"\u003eCAR or TCR copies\/cell = 2 × (CAR or TCR \/ SCG)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr\u003e\n                        \u003ctd\u003eSample types\u003c\/td\u003e\n                        \u003ctd\u003ePurified genomic DNA from CAR-T, TCR-T or other cells with lentiviral integration\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection class=\"shentek-section\"\u003e\n        \u003cdiv class=\"shentek-grid shentek-grid--2col\"\u003e\n            \u003cdiv\u003e\n                \u003ch3 class=\"shentek-heading\"\u003eFeatures\u003c\/h3\u003e\n                \u003cul class=\"shentek-list\"\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eMultiplex absolute quantitation:\u003c\/strong\u003e Simultaneous detection of CAR\/TCR target, single copy gene (SCG) and IPC in the same reaction for absolute copy number determination using a standard curve.\u003c\/li\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eReference standard included:\u003c\/strong\u003e Proprietary reference standard supplied and pre-dilution scheme provided for a 5-point standard curve.\u003c\/li\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eReady-to-use primer \u0026amp; probe mixes:\u003c\/strong\u003e Pre-formulated CAR\/TCR Primer \u0026amp; Probe MIX and IPC MIX simplify assay setup and reduce pipetting error.\u003c\/li\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eCompatible with common qPCR platforms:\u003c\/strong\u003e Validated for use on SHENTEK-96S, ABI 7500, LineGene 9600plus, CFX96 and similar real-time PCR instruments.\u003c\/li\u003e\n                    \u003cli\u003e\n\u003cstrong\u003eDesigned for lentiviral vector applications:\u003c\/strong\u003e Optimized for quantifying transgene copy numbers from HIV-1 derived lentiviral vectors (CAR\/TCR).\u003c\/li\u003e\n                \u003c\/ul\u003e\n            \u003c\/div\u003e\n            \u003cdiv\u003e\n                \u003ch3 class=\"shentek-heading\"\u003eApplications\u003c\/h3\u003e\n                \u003cul class=\"shentek-list\"\u003e\n                    \u003cli\u003eQuantification of CAR or TCR transgene copy number in CAR-T and TCR-T cell products\u003c\/li\u003e\n                    \u003cli\u003eLentiviral vector integration assessment\u003c\/li\u003e\n                    \u003cli\u003ePreclinical and research cell therapy product characterization\u003c\/li\u003e\n                    \u003cli\u003eQuality control and batch testing for gene-modified cell products (research use)\u003c\/li\u003e\n                \u003c\/ul\u003e\n            \u003c\/div\u003e\n            \u003cdiv\u003e\n                \u003ch3 class=\"shentek-heading\"\u003eKit Contents\u003c\/h3\u003e\n                \u003cdiv class=\"shentek-box\"\u003e\n                    \u003cdiv class=\"shentek-box-row\"\u003e\n                        \u003cspan\u003eqPCR Reaction Buffer (NNB001) 850 μL × 2 tubes\u003c\/span\u003e\u003cstrong\u003e-20 °C, protect from light\u003c\/strong\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv class=\"shentek-box-row\"\u003e\n                        \u003cspan\u003eCAR\/TCR Primer \u0026amp; Probe MIX (NNC032) 300 μL × 1 tube\u003c\/span\u003e\u003cstrong\u003e-20 °C\u003c\/strong\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv class=\"shentek-box-row\"\u003e\n                        \u003cspan\u003eIPC MIX (NNC066) 150 μL × 1 tube\u003c\/span\u003e\u003cstrong\u003e-20 °C\u003c\/strong\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv class=\"shentek-box-row\"\u003e\n                        \u003cspan\u003eDNA Dilution Buffer (DDB) (NND001) 1.5 mL × 3 tubes\u003c\/span\u003e\u003cstrong\u003e2–8 °C (store remaining DDB at 2–8 °C); -20 °C for long term per kit table\u003c\/strong\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv class=\"shentek-box-row\"\u003e\n                        \u003cspan\u003eCAR\/TCR Control (NNA022) 50 μL × 1 tube\u003c\/span\u003e\u003cstrong\u003e-20 °C\u003c\/strong\u003e\n                    \u003c\/div\u003e\n                    \u003cdiv class=\"shentek-box-note\"\u003e* Total: 100 reactions | Method: qPCR (multiplex absolute quantitation, standard curve)\u003c\/div\u003e\n                \u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cdiv\u003e\n                \u003ch3 class=\"shentek-heading\"\u003eAttention\u003c\/h3\u003e\n                \u003cdiv class=\"shentek-box shentek-box--warning\"\u003e\n                    \u003cp\u003e• For Research Use Only (RUO). Not for use in diagnostic procedures.\u003c\/p\u003e\n                    \u003cp\u003e• Read Material Safety Data Sheets (MSDS) and follow handling instructions; wear protective eyewear, mask, clothing and gloves.\u003c\/p\u003e\n                    \u003cp\u003e• Work in a clean environment: irradiate bench, pipettes and tubes with UV for 30 minutes and disinfect with 75% ethanol to avoid contamination.\u003c\/p\u003e\n                    \u003cp\u003e• Avoid assay inhibitors; monitor IPC Ct — if sample IPC Ct is significantly higher than NCS IPC Ct, sample may be inhibitory.\u003c\/p\u003e\n                    \u003cp\u003e• NTC and NCS Ct should be larger than the mean Ct of the lowest standard concentration.\u003c\/p\u003e\n                    \u003cp\u003e• Prepare and run triplicates for standards, NTC, NCS and test samples where possible.\u003c\/p\u003e\n                    \u003cp\u003e• Recommended sample input per well: 5 ng–30 ng total DNA (optimize as needed).\u003c\/p\u003e\n                    \u003cp\u003e• Store kit components as labeled (-20 °C) and protect from light; kit stable up to 24 months. If DDB is cloudy, heat to 37 °C until clear.\u003c\/p\u003e\n                    \u003cp\u003e• Seal plates\/tubes, mix and briefly centrifuge before running; follow instrument-specific setup and analysis instructions.\u003c\/p\u003e\n                \u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \n    \u003csection class=\"shentek-section shentek-section--lg\"\u003e\n        \u003ch3 class=\"shentek-subtitle shentek-subtitle--bar\"\u003eQuality Management \u0026amp; Certifications\u003c\/h3\u003e\n        \u003cdiv class=\"shentek-grid shentek-grid--4col\"\u003e\n            \u003cdiv class=\"shentek-card\"\u003e\n                \u003ch4 class=\"shentek-card-title\"\u003eQuality System\u003c\/h4\u003e\n                \u003ca class=\"shentek-btn\" href=\"#\"\u003eDownload QMS\u003c\/a\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-card\"\u003e\n                \u003ch4 class=\"shentek-card-title\"\u003eQMS (ISO, GMP)\u003c\/h4\u003e\n                \u003ca class=\"shentek-btn\" href=\"#\"\u003eDownload Certificate\u003c\/a\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-card\"\u003e\n                \u003ch4 class=\"shentek-card-title\"\u003eQuality Advantages\u003c\/h4\u003e\n                \u003ca class=\"shentek-btn\" href=\"#\"\u003eView Report\u003c\/a\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-card\"\u003e\n                \u003ch4 class=\"shentek-card-title\"\u003eQuality Control Process\u003c\/h4\u003e\n                \u003ca class=\"shentek-btn\" href=\"#\"\u003eDownload Process\u003c\/a\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\u003csection class=\"shentek-section shentek-section--card\"\u003e\n        \u003ch3 class=\"shentek-subtitle shentek-subtitle--icon\"\u003e\n            \u003cspan class=\"shentek-subtitle-icon\"\u003e📂\u003c\/span\u003e Technical Resources \u0026amp; Downloads\n        \u003c\/h3\u003e\n        \u003cdiv class=\"shentek-grid shentek-grid--downloads\"\u003e\n            \u003ca class=\"shentek-download-link\" href=\"https:\/\/files.biofargo.com\/shentek\/coa\/SK030221CA100.pdf\" target=\"_blank\"\u003e\n                \u003cspan class=\"shentek-pdf-icon\"\u003ePDF\u003c\/span\u003e Product Manual \u003cspan class=\"shentek-arrow\"\u003e↓\u003c\/span\u003e\n            \u003c\/a\u003e\n            \u003ca class=\"shentek-download-link\" href=\"https:\/\/files.biofargo.com\/shentek\/msds\/SK030221CA100.pdf\" target=\"_blank\"\u003e\n                \u003cspan class=\"shentek-pdf-icon\"\u003ePDF\u003c\/span\u003e MSDS \/ SDS \u003cspan class=\"shentek-arrow\"\u003e↓\u003c\/span\u003e\n            \u003c\/a\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection class=\"shentek-section\"\u003e\n        \u003ch3 class=\"shentek-subtitle shentek-subtitle--bar\"\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n        \u003cdiv class=\"shentek-faq\"\u003e\n            \u003cdiv class=\"shentek-faq-item shentek-faq-item--alt\"\u003e\n                \u003cdiv class=\"shentek-faq-question\"\u003eQ1: What sample type and amount should I use for the assay?\u003c\/div\u003e\n                \u003cdiv class=\"shentek-faq-answer\"\u003eUse purified genomic DNA from CAR-T, TCR-T or other cells with lentiviral integration. The recommended total DNA per well is between 5 ng and 30 ng; adjust based on preliminary experiments.\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-faq-item\"\u003e\n                \u003cdiv class=\"shentek-faq-question\"\u003eQ2: How is transgene copies per cell calculated?\u003c\/div\u003e\n                \u003cdiv class=\"shentek-faq-answer\"\u003eCalculate CAR or TCR copies per cell using the formula: CAR or TCR copies\/cell = 2 × (CAR or TCR \/ SCG), where CAR\/TCR and SCG quantities are measured from the standard curve (copies\/μL).\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-faq-item shentek-faq-item--alt\"\u003e\n                \u003cdiv class=\"shentek-faq-question\"\u003eQ3: What are the qPCR thermal cycling conditions?\u003c\/div\u003e\n                \u003cdiv class=\"shentek-faq-answer\"\u003eActivation 95 °C for 10:00 (1 cycle); Denaturation 95 °C for 00:15 (40 cycles); Annealing\/Extension 60 °C for 01:00 with fluorescence read during this step.\u003c\/div\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-faq-item\"\u003e\n                \u003cdiv class=\"shentek-faq-question\"\u003eQ4: How should I interpret IPC and control results?\u003c\/div\u003e\n                \u003cdiv class=\"shentek-faq-answer\"\u003eMean Ct-IPC of sample should be within ±1.0 of the NCS Ct-IPC; a significantly higher IPC Ct indicates possible inhibition. NTC and NCS Ct values should be larger than the mean Ct of the lowest standard.\u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003cdiv class=\"shentek-notice\"\u003e\n        \u003cdiv class=\"shentek-notice-header\"\u003e\n            \u003csvg class=\"shentek-notice-icon\" viewbox=\"0 0 20 20\" fill=\"currentColor\"\u003e\n                \u003cpath fill-rule=\"evenodd\" d=\"M8.257 3.099c.765-1.36 2.722-1.36 3.486 0l5.58 9.92c.75 1.334-.213 2.98-1.742 2.98H4.42c-1.53 0-2.493-1.646-1.743-2.98l5.58-9.92zM11 13a1 1 0 11-2 0 1 1 0 012 0zm-1-8a1 1 0 00-1 1v3a1 1 0 002 0V6a1 1 0 00-1-1z\" clip-rule=\"evenodd\"\u003e\u003c\/path\u003e\n            \u003c\/svg\u003e\n            \u003ch3 class=\"shentek-notice-title\"\u003eResearch Use Only\u003c\/h3\u003e\n        \u003c\/div\u003e\n        \u003cdiv class=\"shentek-notice-body\"\u003e\n            \u003cdiv class=\"shentek-notice-item\"\u003e\n                \u003cspan class=\"shentek-notice-check\"\u003e✔\u003c\/span\u003e\n                \u003cp class=\"shentek-notice-text\"\u003e\u003cstrong\u003eResearch Use Only (RUO)\u003c\/strong\u003e – This product is intended\n                    for laboratory research purposes only and not for clinical or regulatory diagnostic use.\u003c\/p\u003e\n            \u003c\/div\u003e\n            \u003cdiv class=\"shentek-notice-item\"\u003e\n                \u003cspan class=\"shentek-notice-check\"\u003e✔\u003c\/span\u003e\n                \u003cp class=\"shentek-notice-text\"\u003eNot intended for use in USDA or FDA regulated diagnostic testing or\n                    official compliance testing.\u003c\/p\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"SHENTEK","offers":[{"title":"100 Reactions","offer_id":45181277864117,"sku":"SK030221CA100","price":1751.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/CARTCRTransgeneCopyNumberQuantitationKitSHENTEK.jpg?v=1757316229","url":"https:\/\/biofargo.com\/products\/car-tcr-transgene-copy-number-quantitation-kit","provider":"Biofargo","version":"1.0","type":"link"}