{"product_id":"auto-pure-20b-automated-cell-isolation-system-with-flexible-throughput","title":"Auto-Pure 20B Automated Cell Isolation System With Flexible Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe Auto-Pure 20B automated magnetic bead cell isolation system is designed for efficient PBMC isolation, supporting the Revvity T-SPOT™.TB test and T-Cell Select™ reagent kit. A dedicated protocol enables rapid and automated processing of peripheral blood mononuclear cells.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe system utilizes magnetic rod technology to perform mixing, binding, washing, and elution steps, ensuring consistent purification performance.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eBuilt-in flexibility:\u003c\/strong\u003e Strip-based operation allows variable batch sizes, optimizing consumable usage and improving workflow efficiency.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eEasy operation with minimal maintenance requirements\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e7-inch full-color touchscreen interface with shortcut keys\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eWalk-away operation: up to 20 samples processed in under 45 minutes\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDrawer-based design for convenient loading\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003ePre-loaded T-Cell Select reagent protocol\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eIntegrated lighting and exhaust system\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eUV sterilization function for contamination control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Specifications --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProcessing Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e3.5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Quantity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1–20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProtocol Storage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePre-loaded T-Cell Select reagent protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eExternal Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUSB, Ethernet port, Wi-Fi, built-in SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eEnvironmental temperature: 10–35 °C\u003cbr\u003eRelative humidity: ≤ 70 %\u003cbr\u003eInput voltage: AC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e400 × 520 × 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eAutomated PBMC Isolation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eMagnetic bead-based system enables efficient and reproducible PBMC purification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eMagnetic Rod Technology\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomates mixing, binding, washing, and elution for consistent results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eHigh Throughput Efficiency\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses up to 20 samples in under 45 minutes with minimal hands-on time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eFlexible Operation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eStrip-based workflow supports variable batch sizes and optimized reagent usage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003ePreloaded Protocols\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eIncludes dedicated T-cell isolation protocol for standardized workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eUser-Friendly Interface\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003e7-inch touchscreen with intuitive controls for easy operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eEnhanced Safety\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eUV sterilization, internal lighting, and exhaust system support contamination control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eCompact Design\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eSpace-saving benchtop system with convenient drawer-based loading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eTB Immunology Testing:\u003c\/strong\u003e PBMC isolation for T-cell based tuberculosis assays such as ELISPOT workflows.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCell Isolation \u0026amp; Preparation:\u003c\/strong\u003e Enrichment of mononuclear cells for downstream immunological analysis.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical Laboratory Automation:\u003c\/strong\u003e Standardized sample preparation for diagnostic workflows.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eImmunology Research:\u003c\/strong\u003e PBMC preparation for cytokine studies and immune monitoring.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Processing:\u003c\/strong\u003e Rapid handling of multiple samples for routine and research applications.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377865748661,"sku":"Auto-Pure 20B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Auto-Pure_20B_Automated_Cell_Isolation_System_With_Flexible_Throughput.jpg?v=1774319588","url":"https:\/\/biofargo.com\/products\/auto-pure-20b-automated-cell-isolation-system-with-flexible-throughput","provider":"Biofargo","version":"1.0","type":"link"}