{"title":"Imaging \u0026 Testing","description":"","products":[{"product_id":"uv-visible-spectrophotometer","title":"UV\/Visible Spectrophotometer - Tungsten lamp \u0026 deuterium lamp - 4010120102","description":"\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUser Friendly Operation and Information Rich LCD Display: The large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.\u003c\/li\u003e\n\u003cli\u003eOn-Board Data Storage: The System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.\u003c\/li\u003e\n\u003cli\u003eData can be restored after a sudden power failure.\u003c\/li\u003e\n\u003cli\u003eAuto setting wavelength: To set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.\u003c\/li\u003e\n\u003cli\u003eAutomatic Switching: Tungsten\u0026amp; Deuterium lamps switching is automatic. Selectable from a wavelength range of  190 to 1100nm.\u003c\/li\u003e\n\u003cli\u003ePC control through application software: The spectrophotometer is fully equipped and capable of executing all functions in stand-alone mode. The optional application software 'Wave Professional' provides computer control for the spectrophotometer(through the built-in USB port), apart from other functions such as spectrum scan, Time scan(kinetics), multi-wavelength scanning \u0026amp; Nucleic Acid \/Protein measurement. (SP-V1100\/SP-UV1100)\u003c\/li\u003e\n\u003cli\u003eLarge sample compartment: To accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 90%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e\u003cstrong\u003eSP-UV1100\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eOptical System\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eSingle Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eTungsten \u0026amp; Deuterium lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e2.0nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e 190-1100nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e±0.5nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e≤0.3nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e -0.3-3.0A, 0-200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e±0.002A@0.5A,\u003cbr\u003e ±0.004A@1.0A,\u003cbr\u003e±0.3%T@100%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cdiv\u003ePhotometric Repeatability\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e≤0.001A@0.5A,\u003cbr\u003e≤0.002A@1.0A,\u003cbr\u003e≤0.15%T@100%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eStability\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e≤0.002A\/h @500nm\u003cbr\u003e(after preheat 2 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eStray Light\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e≤0.05%T@220\u0026amp;360nm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eSample Compartment\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e4-position,10mm\u003cbr\u003epath-length cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eDisplay \u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eUSB Port \u0026amp; Parallel Port (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e110\/220VAC,50\/60Hz,120W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eDimension (L * W * H)\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e490 * 360 * 210mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 30px; text-align: center; vertical-align: middle;\"\u003e14kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DLAB","offers":[{"title":"Default Title","offer_id":40299190976693,"sku":"4010120102","price":3839.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/products\/SP-UV1100.jpg?v=1732886041"},{"product_id":"lcd-spectrophotometer-tungsten-lamp-dlab-sp-v1000","title":"SP-V1000 LCD  Spectrophotometer-Tungsten Lamp","description":"\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003eKey Features\u003c\/h2\u003e\n\u003ch3\u003eUser Friendly Operation and Information Rich LCD Display:\u003c\/h3\u003e\n\u003cp\u003eThe large  128  x  64  dots, backlit LCD screen with adjustable brightness control displays a large array of data also in graphical format.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eOn-Board Data Storage: \u003c\/h3\u003e\n\u003cp\u003eThe System can save the test results, up to 200 groups of data and 200 standard curves in the RAM memory.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003eData can be restored after a sudden power failure.\u003c\/h3\u003e\n\u003ch3\u003e\n\u003cbr\u003eAuto setting wavelength: \u003c\/h3\u003e\n\u003cp\u003eTo set wavelength automatically to calibrate the system through arrow keys to avoid operation errors.\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003ePC control through application software: \u003c\/h3\u003e\n\u003cp\u003eThe spectrophotometer is fully equipped and capable of executing all functions in stand-alone mode. The optional application software 'Wave Professional' provides computer control for the spectrophotometer(through the built-in USB port), apart from other functions such as spectrum scan, Time scan(kinetics), multiwavelength scanning \u0026amp; Nucleic Acid \/Protein measurement. (SP-V1100\/SP-UV1100)\u003c\/p\u003e\n\u003ch3\u003e\n\u003cbr\u003eLarge sample compartment: \u003c\/h3\u003e\n\u003cp\u003eTo accommodate 5–100mm path length cuvettes with optional holders. A variety of optional accessories are available.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; height: 342px;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eSpecifications\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eSP-V1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eOptical Systen\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eSingle Beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eSpectral Bandwidth\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e4.0nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e325-1000nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e±2nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWavelength Repeatability\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e≤1nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ePhotometric Range\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e-0.3-3.0A， 0-200%T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ePhotometric Accuracy\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e\n\u003cdiv\u003e±0.003A@0.5A,\u003c\/div\u003e\n\u003cdiv\u003e±0.006A@1.0A,\u003c\/div\u003e\n\u003cdiv\u003e±0.5%T@100%T\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ePhotometric Repeatability\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e\n\u003cdiv\u003e≤0.0015A@0.5A,\u003c\/div\u003e\n\u003cdiv\u003e≤0.003A@1.0A,\u003c\/div\u003e\n\u003cdiv\u003e≤0.25%T@100%T\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eStability\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e≤0.002A\/h @500nm\u003cbr\u003e(after preheat 2 hours)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eStray Light\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e≤0.2%T@360nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eSample Compartment\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e4-position,10mm\u003cbr\u003epathlength cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eDisplay\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eOutput \u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eUSB Port\u0026amp;Parallel Port (Printer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e110\/220VAC, 50\/60Hz,80W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eDimension (L×W×H)\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e490×360×210mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e12kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DLAB","offers":[{"title":"SP-V1000","offer_id":52339085607093,"sku":"4010210103","price":1328.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/products\/8921628330940_.pic_hd.jpg?v=1732875925"},{"product_id":"e-blot-western-blot-imaging-system","title":"E-Blot Touch Imager","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003csection class=\"elementor-section elementor-top-section elementor-element elementor-element-18b8c7d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"18b8c7d\" data-element_type=\"section\"\u003e\n\u003cdiv class=\"elementor-container elementor-column-gap-default\"\u003e\n\u003cdiv class=\"elementor-row\"\u003e\n\u003cdiv class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-538fd4b\" data-id=\"538fd4b\" data-element_type=\"column\"\u003e\n\u003cdiv class=\"elementor-column-wrap elementor-element-populated\"\u003e\n\u003cdiv class=\"elementor-widget-wrap\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-ea73045 elementor-widget elementor-widget-text-editor\" data-id=\"ea73045\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\n\u003cdiv\u003e\n\u003cdiv id=\"7157083500053528582\" class=\"js-message-item message-item message-not-self message-item-first message-is-p2p message-me-read message-comment text-message\" data-position=\"126\" data-badge-count=\"127\"\u003e\n\u003cdiv class=\"message-right\"\u003e\n\u003cdiv class=\"message-section\"\u003e\n\u003cdiv class=\"MessageContextMenuTrigger MessageContextMenuTrigger--scene-chat message-section-left is-reply message-section-newFileCard\" data-element=\"message-section-left\"\u003e\n\u003cdiv class=\"message-content-container\"\u003e\n\u003cdiv class=\"message-content\"\u003e\n\u003cdiv class=\"message-text\"\u003e\n\u003cdiv class=\"limit-height-container\"\u003e\n\u003cdiv class=\"wrapper\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"richTextContainer\"\u003e\n\u003cspan class=\"text-only\" data-eleid=\"3-0\" style=\"color: rgb(0, 0, 0); font-size: 0.875rem;\"\u003e\u003cstrong\u003eRequest for a quotation or a demo:\u003c\/strong\u003e \u003c\/span\u003e\u003ca class=\"link rich-text-anchor __anchor-intercept-flag__\" href=\"mailto:contact@biofargo.com\" data-eleid=\"3-1\" style=\"color: #000000;\" target=\"_blank\"\u003econtact@biofargo.com\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"richTextContainer\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"message-section-right\"\u003e\n\u003ch2 class=\"toolbar-panel\" data-lock-ui=\"true\"\u003eSpecification\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003ctable border=\"1\" style=\"width: 90%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eCapture mode\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eAuto\/Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eFull well capacity\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e1,250,000.00 electrons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eData transferring speed\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e1000Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eLight Sources control\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eChemoluminescenee,Epi.white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eStart up waiting\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eExposure time\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e\u0026gt;95% Samples are imaged within 1sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003ePhoto sensor chip\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e158cm\u003csup\u003e2\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eUser account management\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eMulti-user management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eNet weight\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e4.35 KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eDimenslon （L x Wx H）\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e27cmx20.6cmx5.4cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e100-250V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e4-30℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003eOperating humidity\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 3px; text-align: center; vertical-align: middle;\"\u003e10-85% relative humidity(noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWestern Blot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSouthern Blot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNorthern Blot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDot Blot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsotope Image\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eE-Blot Touch imager makes chemiluminescence imaging simple and easy.\u003cbr\u003eThe revolutionary touch chemiluminescence imaging technology of e-Blot takes full advantage of the high sensitivity of the chemiluminescence method, overcomes many shortcomings of cold CDD imaging, and improves the imaging sensitivity, 2-3 logs higher quantitative range and efficiency, leading western imaging into a whole new era.\u003c\/p\u003e\n\u003ch2\u003eBenefits of E-Blot touch imager\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e2 orders of magnitude higher than cooled CCD on sensitivity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 orders of magnitude higher than cooled CCD on quantita-tive range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMore than 95% of the samples are imaged within seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for direct isotope imaging at low cost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact size, saves 90% of space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo need to optimize te imaging.One-click to get ideal result\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal-indestructive contact imaging - the first instrument to achieve absolute sensitivity unmatched by compression technology:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv data-docx-has-block-data=\"false\" data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\"\u003e\n\u003cdiv data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\" data-docx-has-block-data=\"false\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-doxusuWeeeoWS0GE88Wd9wmwLac\"\u003e\n\u003cul class=\"list-bullet1\" start=\"1\"\u003e\u003c\/ul\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-doxuscMiIqE4QIYKeGcChFkN49b\"\u003e\u003cspan style=\"color: #000000;\"\u003e1) optical film imaging 2) cold ccd imaging 3) E-blot contact imaging\u003c\/span\u003e\u003c\/div\u003e\n\u003ch2 class=\"ace-line ace-line old-record-id-doxuscMiIqE4QIYKeGcChFkN49b\"\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cimg src=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0521\/5312\/2997\/files\/1280X1280_480x480.png?v=1666362191\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eCompared with other brands\u003c\/h2\u003e\n\u003cdiv data-docx-has-block-data=\"false\" data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\"\u003e\n\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cimg src=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0521\/5312\/2997\/files\/1280X1280-2_480x480.png?v=1666362329\" alt=\"\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cvideo controls=\"controls\" width=\"80%\"\u003e\n  \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/c2e6da5aabba4f29a1854506e956c38d.mp4\"\u003e\nYour browser does not support the video tag.\n\u003c\/source\u003e\u003c\/video\u003e\n\u003c\/div\u003e\n\u003cp class=\"ace-line ace-line old-record-id-doxusuWeeeoWS0GE88Wd9wmwLac\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"ace-line ace-line old-record-id-doxusuWeeeoWS0GE88Wd9wmwLac\"\u003eResource\u003c\/h2\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-doxusuWeeeoWS0GE88Wd9wmwLac\"\u003e\n\u003cp data-docx-has-block-data=\"false\" data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0521\/5312\/2997\/files\/Touch_Imager_Brochure_2365091a-f78c-47bc-a716-b72efb640946.pdf?v=1666363055\" style=\"color: rgb(43, 0, 255);\" type=\"application\/pdf\" target=\"_blank\"\u003eeBlot\u003csup\u003eTM\u003c\/sup\u003e Quick Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv data-docx-has-block-data=\"false\" data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\"\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0521\/5312\/2997\/files\/211202.pdf?v=1666363054\" type=\"application\/pdf\" target=\"_blank\"\u003eeBlot\u003csup\u003eTM\u003c\/sup\u003e Manual\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv data-docx-has-block-data=\"false\" data-page-id=\"doxusv94Mp3ytJwB0dIEUIgbOIf\"\u003e\n\u003cspan style=\"color: #000000;\"\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e \u003ca style=\"color: rgb(43, 0, 255);\" href=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0521\/5312\/2997\/files\/210401.pdf?v=1666363066\" type=\"application\/pdf\" target=\"_blank\"\u003eeBlot\u003csup\u003eTM\u003c\/sup\u003e L1 Flyer\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e \u003c\/span\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-doxuscMiIqE4QIYKeGcChFkN49b\"\u003e\n\u003cspan style=\"color: #000000;\" data-lark-record-data='{\"rootId\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"text\":{\"initialAttributedTexts\":{\"text\":{\"0\":\"Compared with other brands:\"},\"attribs\":{\"0\":\"*0*1+r\"}},\"apool\":{\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"],\"1\":[\"bold\",\"true\"]},\"nextNum\":2}},\"type\":\"ordered\",\"referenceRecordMap\":{},\"extra\":{\"mention_page_title\":{},\"external_mention_url\":{}},\"isKeepQuoteContainer\":false,\"isCut\":false}' data-lark-record-format=\"docx\/text\" class=\"lark-record-clipboard\"\u003e \u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan style=\"color: #000000;\" class=\"lark-record-clipboard\" data-lark-record-format=\"docx\/record\" data-lark-record-data='{\"isCut\":false,\"rootId\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"parentId\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"blockIds\":[22,23,24,25,26,27,28,29,30],\"recordIds\":[\"doxusMqEGU0su0wCQ8bJAgJd4ke\",\"doxuseeOA6saUek885XOV7my9dV\",\"doxusWEsewY4IcusugQjuScGjee\",\"doxus6EqWSoemouWU3IJb7UAknp\",\"doxus0meuSqei4WguwbHaFSUt1e\",\"doxusQi4oW2kuoei40u9ySvzOth\",\"doxus6oK4UUMykI86y8sLSIcOkh\",\"doxusKEQKAAsUw80uQ1W9FIdQ9d\",\"doxuscMiIqE4QIYKeGcChFkN49b\"],\"recordMap\":{\"doxusMqEGU0su0wCQ8bJAgJd4ke\":{\"id\":\"doxusMqEGU0su0wCQ8bJAgJd4ke\",\"snapshot\":{\"type\":\"ordered\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"initialAttributedTexts\":{\"text\":{\"0\":\"Benefits of e-Blot touch imager:\"},\"attribs\":{\"0\":\"*0*1+p*0*1*2+6*0*1+1\"}},\"apool\":{\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"],\"1\":[\"bold\",\"true\"],\"2\":[\"grammarly-data\",\"{\\\"id\\\":\\\"208b19ba-2d57-44f5-8527-88c0eb34a23a\\\",\\\"operation\\\":\\\"replace\\\",\\\"origin_text\\\":\\\"imager\\\",\\\"replace_text\\\":\\\"imagery\\\",\\\"rule_id\\\":\\\"1001\\\",\\\"rule_description\\\":\\\"Possible Spelling Issue@02166619759123100000000000000000000ffffdcdaad48dbcd4a@en@25@0\\\",\\\"is_ignore\\\":0}\"]},\"nextNum\":3}},\"align\":\"\",\"folded\":false,\"seq\":\"6\"}},\"doxuseeOA6saUek885XOV7my9dV\":{\"id\":\"doxuseeOA6saUek885XOV7my9dV\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":1,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+1o\"},\"text\":{\"0\":\"2 orders of magnitude higher than cooled CCD on sensitivity.\"}}},\"align\":\"\",\"folded\":false}},\"doxusWEsewY4IcusugQjuScGjee\":{\"id\":\"doxusWEsewY4IcusugQjuScGjee\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":2,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"],\"1\":[\"grammarly-data\",\"{\\\"id\\\":\\\"d6af1067-bf4c-4e88-8256-ca723ed24d2e\\\",\\\"operation\\\":\\\"replace\\\",\\\"origin_text\\\":\\\"quantita\\\",\\\"replace_text\\\":\\\"quantity\\\",\\\"rule_id\\\":\\\"1001\\\",\\\"rule_description\\\":\\\"Possible Spelling Issue@02166619747385400000000000000000000ffffdcdaad480c7266@en@108@0\\\",\\\"is_ignore\\\":0}\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+1c*0*1+8*0+c\"},\"text\":{\"0\":\"2 orders of magnitude higher than cooled CCD on quantita-tive range.\"}}},\"align\":\"\",\"folded\":false}},\"doxus6EqWSoemouWU3IJb7UAknp\":{\"id\":\"doxus6EqWSoemouWU3IJb7UAknp\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":1,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+1j\"},\"text\":{\"0\":\"More than 95% of the samples are imaged within seconds.\"}}},\"align\":\"\",\"folded\":false}},\"doxus0meuSqei4WguwbHaFSUt1e\":{\"id\":\"doxus0meuSqei4WguwbHaFSUt1e\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":1,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+1c\"},\"text\":{\"0\":\"Suitable for direct isotope imaging at low cost.\"}}},\"align\":\"\",\"folded\":false}},\"doxusQi4oW2kuoei40u9ySvzOth\":{\"id\":\"doxusQi4oW2kuoei40u9ySvzOth\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":1,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+x\"},\"text\":{\"0\":\"Compact size, saves 90% of space.\"}}},\"align\":\"\",\"folded\":false}},\"doxus6oK4UUMykI86y8sLSIcOkh\":{\"id\":\"doxus6oK4UUMykI86y8sLSIcOkh\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":2,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"],\"1\":[\"grammarly-data\",\"{\\\"id\\\":\\\"6bee5f60-aadd-4601-8449-c3851dc0043d\\\",\\\"operation\\\":\\\"replace\\\",\\\"origin_text\\\":\\\"te\\\",\\\"replace_text\\\":\\\"the\\\",\\\"rule_id\\\":\\\"1001\\\",\\\"rule_description\\\":\\\"Possible Spelling Issue@02166619747385400000000000000000000ffffdcdaad480c7266@en@282@0\\\",\\\"is_ignore\\\":0}\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+k*0*1+2*0+12\"},\"text\":{\"0\":\"No need to optimize te imaging.One-click to get ideal result\"}}},\"align\":\"\",\"folded\":false}},\"doxusKEQKAAsUw80uQ1W9FIdQ9d\":{\"id\":\"doxusKEQKAAsUw80uQ1W9FIdQ9d\",\"snapshot\":{\"type\":\"bullet\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"apool\":{\"nextNum\":2,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"],\"1\":[\"grammarly-data\",\"{\\\"id\\\":\\\"f2a3e2e3-5401-4c02-ae80-a7d1a5394dbf\\\",\\\"operation\\\":\\\"replace\\\",\\\"origin_text\\\":\\\"indestructive\\\",\\\"replace_text\\\":\\\" instructive\\\",\\\"rule_id\\\":\\\"1001\\\",\\\"rule_description\\\":\\\"Possible Spelling Issue@02166619765262000000000000000000000ffffdcdaad486b5c17@en@7@0\\\",\\\"is_ignore\\\":0}\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+7*0*1+d*0+30\"},\"text\":{\"0\":\"Signal-indestructive contact imaging - the first instrument to achieve absolute sensitivity unmatched by compression technology:\"}}},\"align\":\"\",\"folded\":false}},\"doxuscMiIqE4QIYKeGcChFkN49b\":{\"id\":\"doxuscMiIqE4QIYKeGcChFkN49b\",\"snapshot\":{\"type\":\"text\",\"parent_id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"comments\":[],\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[],\"text\":{\"initialAttributedTexts\":{\"text\":{\"0\":\"     1) optical film imaging     2) cold ccd imaging    3) E-blot contact imaging\"},\"attribs\":{\"0\":\"*0+29\"}},\"apool\":{\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]},\"nextNum\":1}},\"align\":\"\",\"folded\":false}},\"doxusv94Mp3ytJwB0dIEUIgbOIf\":{\"id\":\"doxusv94Mp3ytJwB0dIEUIgbOIf\",\"snapshot\":{\"type\":\"page\",\"parent_id\":\"\",\"comments\":null,\"locked\":false,\"hidden\":false,\"author\":\"6995243663240462342\",\"children\":[\"doxusGmcqUOM0weQkSUS5JyH8Ld\",\"doxusASeakqkiSQq2T3uZMCATnB\",\"doxusWk0e44CUYCEYSWLl7wHmhf\",\"doxus4EA8iqU8MaeswhuFze6LSf\",\"doxusMMkyOYMMUIggc72I9ERjgc\",\"doxuskc6sqeSi4eeaYT4VcTQR1g\",\"doxusqyG2ucioEGo0A3FYioxjyd\",\"doxusIyyqoGAWKmMQ27a3dUkcid\",\"doxusQiiEKuOgMC6q8EQ4Seeiec\",\"doxusGUEmyE6KkG8CGQjgJXWBKb\",\"doxus0OUg02wsQ4eOcpNbgYnede\",\"doxusIWYoqq4AiAQKYtxxU8s6ce\",\"doxusiEcYyukqUy8sa6JfovehRh\",\"doxusGqMewi2waKEIQNxTOfHPsg\",\"doxusoWM280c8M2G0AHCjE8hATf\",\"doxusuWeeeoWS0GE88Wd9wmwLac\",\"doxusQCwsyI0Gu88cGk509onGgf\",\"doxusgQWCMsuWEaYCMXLnYiKEUb\",\"doxusqQ8wOqQMU4qCCGn2rboAjh\",\"doxusMqEGU0su0wCQ8bJAgJd4ke\",\"doxuseeOA6saUek885XOV7my9dV\",\"doxusWEsewY4IcusugQjuScGjee\",\"doxus6EqWSoemouWU3IJb7UAknp\",\"doxus0meuSqei4WguwbHaFSUt1e\",\"doxusQi4oW2kuoei40u9ySvzOth\",\"doxus6oK4UUMykI86y8sLSIcOkh\",\"doxusKEQKAAsUw80uQ1W9FIdQ9d\",\"doxuscMiIqE4QIYKeGcChFkN49b\",\"doxusekmYGSGuksIqqeMBwuVzyw\",\"doxusqA2GgWSaEoIacljuNZbDU2\",\"doxusUUEaii0u4qWAYRctwU4J1b\",\"doxus6s8uEYYw0kG4cbGmYx4Ykh\",\"doxusEQIMeME2kgEKMtaAUikg1g\",\"doxuscemYSyAA0CGmgxGXlGogih\",\"doxus4AQmIiSi2uWKk3r2OtrUEg\",\"doxusCy68IMkcsg0GuE6EWe9KXg\",\"doxuseSieimQEOgGgUbuLfEL2QS\",\"doxus6cAuYGM04uMCG8wG9GaWOh\",\"doxus0OSwukmI0cUUgRa4aK9D8f\",\"doxusQoa8aMYSOk0CK2ujXykwMd\",\"doxus0GQS6k02suSagffMGryE0f\"],\"text\":{\"apool\":{\"nextNum\":1,\"numToAttrib\":{\"0\":[\"author\",\"6995243663240462342\"]}},\"initialAttributedTexts\":{\"attribs\":{\"0\":\"*0+9\"},\"text\":{\"0\":\"E-Blot 上架\"}}},\"align\":\"\"}}},\"payloadMap\":{\"doxuscMiIqE4QIYKeGcChFkN49b\":{\"level\":1}},\"extra\":{\"mention_page_title\":{},\"external_mention_url\":{}},\"isKeepQuoteContainer\":false,\"pasteFlag\":\"06fc8c77-3845-4305-90bb-294d610defcd\"}'\u003e \u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"elementor-section elementor-top-section elementor-element elementor-element-9da8126 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9da8126\" data-element_type=\"section\"\u003e\n\u003cdiv class=\"elementor-container elementor-column-gap-default\"\u003e\n\u003cdiv class=\"elementor-row\"\u003e\n\u003cdiv class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-051eb9c\" data-id=\"051eb9c\" data-element_type=\"column\"\u003e\n\u003cdiv class=\"elementor-column-wrap elementor-element-populated\"\u003e\n\u003cdiv class=\"elementor-widget-wrap\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-4beb9da elementor-widget elementor-widget-text-editor\" data-id=\"4beb9da\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"elementor-text-editor elementor-clearfix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"e-BLOT","offers":[{"title":"Default Title","offer_id":42451631931573,"sku":"eblot","price":43260.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1500.jpg?v=1753531879"},{"product_id":"tgreen-transilluminator","title":"TGreen Transilluminator","description":"\u003ch2\u003e\u003cspan\u003eDescription\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eTGreen Transilluminator adopts LED blue light source, amber filter and 470-520 nm excitation light material, which can be used for observation and cutting of gels loaded with GFP protein, or nucleic acid stained with a variety of safety dyes\/ EB. The TGreen Transilluminator can achieve perfect gel observation and cutting effect with no ultraviolet radiation, and provide a safe and humanized laboratory environment. This instrument can also be applied to other fluorescence observation with excitation wavelengths of 470-520 nm, such as proteins, small animals and plants with GFP tag.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e1. High sensitivity: When used with GeneGreen, as low as 0.5 ng (1000 bp) dsDNA can be observed.\u003c\/p\u003e\n\u003cp\u003e2. Safe: Blue light source has no damage to human body, gel and sample.\u003c\/p\u003e\n\u003cp\u003e3. Wide application range: Compatible fluorescent dyes include GeneGreen, GelRed, GelGreen, SYBR Green I, SYBR Safe, Goldview, SYBR Gold, SYPRO Ruby, SYPRO Orange, SYPRO Tangerine, eGFP, Cy2, FITC, EB etc.\u003c\/p\u003e\n\u003cp\u003e4. Long service life: The service life of LED lamps is 50,000 hours.\u003c\/p\u003e\n\u003cp\u003e5. Humanization: Multi-angle rotation of filter facilitates gel cutting.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; height: 162px;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eDimension (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e210 L x 210 W x 30 H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eViewing surface\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e120 x 70 (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e470 (nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eAmber filter\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ethe amber filter is wrapped in a metal frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eLED arrangement\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ethe matrix provides double-sided lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eLED lifetime\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e50000 (h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e24V DC, 2.5 A power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eMaximum adapted gel size\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e110 x 60 (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18px;\"\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 50%; height: 18px; text-align: center;\"\u003e2.3 (kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eComponent\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e1. TGreen Transilluminator: 1 set\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eInstrument Installation\u003c\/h2\u003e\n\u003cp\u003eCarefully open the package and the shield of the TGreen Transilluminator as follows:\u003cbr data-mce-fragment=\"1\"\u003e1. First remove the top foam.\u003cbr data-mce-fragment=\"1\"\u003e2. Remove the instrument from two foam shell and put it on the stable level.\u003cbr data-mce-fragment=\"1\"\u003e3. Remove the plastic protective film from the transparent glass viewing surface and amber filter.\u003c\/p\u003e\n\u003ch2\u003eInstallation and Use\u003c\/h2\u003e\n\u003cp\u003eThe instrument must be placed on the workbench, and there shall not be obstacles within 10 cm around the instrument to keep ventilation.\u003cbr data-mce-fragment=\"1\"\u003eConnect the instrument to the power supply, and the adapter provides 24V DC\u003cbr data-mce-fragment=\"1\"\u003evoltage.\u003c\/p\u003e\n\u003ch2\u003ePrecautions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDo not pour liquid directly on the instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not block vents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower off immediately after use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlace in proper area to prevent injury to the operator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe sample surface of the TGreen Transilluminator is a glass plate for cutting gels. After use, use bleach or industrial alcohol to clean the surface of the TGreen Transilluminator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTGreen Transilluminator is equipped with thermal protection to prevent overheating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlways wear disposable gloves during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eUsage of the Instrument\u003c\/h2\u003e\n\u003cp\u003ePut gel\/sample in the transparent glass support. It is suggested to wear gloves to prevent skin from contacting gel and dye directly. Turn on the switch, and the LED light in the unit starts to light on the glass support. Turn off the power after viewing the sample or cutting the gel.\u003c\/p\u003e\n\u003cdiv id=\"display-search-keyword\" style=\"display:none\"\u003etransil\u003c\/div\u003e","brand":"Tiangen","offers":[{"title":"Default Title","offer_id":43709123526837,"sku":"OSE-470","price":1020.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/TGreen-Transilluminator-400x400.jpg?v=1732884619"},{"product_id":"trinocular-microscope-eyepiece10x-23mmadjustable-viewing-no-built-in-lightsource-10-5-inch-android-smart-all-in-one-1-pcs-case","title":"Trinocular Microscope-Eyepiece with 10X magnification and 23mm adjustable viewing-No built-in lightsource-10.5 inch Android smart all-in-one-1 unit per case","description":"\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrinocular Microscope, Eyepiece10X\/23mm(adjustable viewing)\u003c\/li\u003e\n\u003cli\u003eNo built-in lightsource\u003c\/li\u003e\n\u003cli\u003e10.5 inch Android smart all-in-oneYW5699B\u003c\/li\u003e\n\u003cli\u003e0.5x camera C interface SZ-0.5x Cwith four-zone control ring HS-72\u003c\/li\u003e\n\u003cli\u003e1-yearwarranty\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Biologix","offers":[{"title":"Default Title","offer_id":43964474851509,"sku":"DK-31023CK","price":1978.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/4187621797.jpg?v=1732885354"},{"product_id":"trinocular-microscope-eyepiece-10x-23mmadjustable-viewing-with-10-5-inch-android-smart-all-in-one-1-piece-case","title":"Trinocular Microscope-Eyepiece with 10X magnification and 23mm adjustable viewing-With 10.5 inch Android smart all-in-one-1 unit per case","description":"\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrinocular Microscope, eyepiece 10X\/23mm(adjust-able viewing)\u003c\/li\u003e\n\u003cli\u003eExternal bottom light source and ring light, 3W-LEDlight source, and external double goose tube light source are available\u003c\/li\u003e\n\u003cli\u003e1-year warranty\u003c\/li\u003e\n\u003cli\u003eDK-31023CS: with 10.5inch Android smart all-in-one\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 99.646%; height: 43px;\" data-mce-style=\"border-collapse: collapse; width: 99.646%; height: 43px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 15.0442%;\"\u003e\n\u003cp\u003eCat #\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 26.1947%;\"\u003e\n\u003cp\u003eProduct\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 17.8761%;\"\u003e\n\u003cp\u003eEyepieces(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 40.708%;\"\u003e\n\u003cp\u003eLight Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 35px;\"\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 15.0442%;\"\u003e\n\u003cp\u003eDK-31023CS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 26.1947%;\"\u003e\n\u003cp\u003eTrinocular Microscope\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 17.8761%;\"\u003e\n\u003cp\u003e10X\/23\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center; height: 35px; width: 40.708%;\"\u003e\n\u003cp\u003e3W-LED light source and ring light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biologix","offers":[{"title":"Default Title","offer_id":43964474949813,"sku":"DK-31023CS","price":2102.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/4187568418.jpg?v=1732885357"},{"product_id":"trinocular-microscope-eyepiece-10x-23mmadjustable-viewing-with-external-double-goose-tube-light-source-1-piece-case","title":"Trinocular Microscope-Eyepiece with 10X magnification and 23mm adjustable viewing-With external double goose tube light source-1 unit per case","description":"\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrinocular Microscope, eyepiece 10X\/23mm(adjust-able viewing)\u003c\/li\u003e\n\u003cli\u003eExternal bottom light source and ring light, 3W-LEDlight source, and external double goose tube light source are available\u003c\/li\u003e\n\u003cli\u003e1-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eOrdering Information\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eCat #\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eProduct\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eEyepieces(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eLight Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eDK-31023\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eTrinocular Microscope\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003e10X\/23\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\n\u003cp\u003eExternal double goose tube light source LED-06W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biologix","offers":[{"title":"Default Title","offer_id":43964474982581,"sku":"DK-31023","price":1068.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/4187569486.jpg?v=1732885359"},{"product_id":"trinocular-microscope-eyepiece-10x-23mmadjustable-viewing-with-intelligent-measuring-camera-1-pcs-case","title":"Trinocular Microscope-Eyepiece with 10X magnification and 23mm adjustable viewing-With intelligent measuring camera-1 unit per case","description":"\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTrinocular Microscope, eyepiece 10X\/23mm(adjust-able viewing)\u003c\/li\u003e\n\u003cli\u003eExternal bottom light source and ring light, 3W-LEDlight source, and external double goose tube light source are available\u003c\/li\u003e\n\u003cli\u003e1-year warranty\u003c\/li\u003e\n\u003cli\u003eDK-31023C: with intelligent measuring camera\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%; height: 140px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 70px;\"\u003e\n\u003ctd style=\"width: 13.7447%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eCat #\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.8612%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eProduct\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.2511%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eEyepieces(mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 46.0028%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eLight Source\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 70px;\"\u003e\n\u003ctd style=\"width: 13.7447%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eDK-31023C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 22.8612%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eTrinocular Microscope\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 17.2511%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003e10X\/23\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 46.0028%; text-align: center; line-height: 70px; height: 70px;\"\u003e\n\u003cp\u003eExternal bottom ight source and ring light\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biologix","offers":[{"title":"Default Title","offer_id":43964475736245,"sku":"DK-31023C","price":1631.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/4185425371.jpg?v=1732885361"},{"product_id":"tgem-ultra-spectrophotometer-tiangen","title":"TGem Ultra Spectrophotometer - Tiangen","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe TGem Ultra is an all-in-one full wavelength micro UV-Vis spectrophotometer with a pedestal that can detect micro amount of samples from 0.5-2 ul with very high accuracy and reproducibility. In pedestal test, based on the surface tension, the sample retains between the two measuring fibers, allowing the instrument to detect higher concentrations of samples without dilution, and to adjust the pathlength between the fibers in real time for more accurate assay data. The flagship version (OSE-260-06) is equipped with a cuvette measurement module for enzyme kinetic analysis and measurement of low concentration samples.\u003c\/p\u003e\n\u003ch2 class=\"bold\"\u003eCatalog Number \/ Packaging\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003e\u003cstrong\u003eCat.no.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003e\u003cstrong\u003ePackage\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eOSE-260-03\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eSet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eOSE-260-05\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eSet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eOSE-260-06\u003c\/td\u003e\n\u003ctd style=\"width: 50%; text-align: center;\"\u003eSet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMicrosample input: only 0.5-2 ul is required for base loading, saving\u003c\/p\u003e\n\u003cp\u003eprecious samples.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic test: Automatic test can start when the pedestal arm is down.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide measurement range: the pedestal test concentration range is 2-27500\u003c\/p\u003e\n\u003cp\u003eng\/ul.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFull wavelength test: it can detect in the wavelength range of 185-910 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEasy to operate: built-in 7-inch high-resolution color capacitive touchscreen, and the friendly operation interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePerformance Parameters\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 98.1297%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProduct name \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTGem Pro Spectrophotometer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTGem Ultra Spectrophotometer (Standard) \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"202\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTGem Ultra Spectrophotometer (Cuvette) \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003eOSE-260-03\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003eOSE-260-05\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"202\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003eOSE-260-06\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eTest unit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003eLinear CCD array\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"400\" colspan=\"2\" style=\"width: 46.6228%; text-align: center;\"\u003e\n\u003cp\u003eLinear CCD array\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eMinimum sample volume (μl)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e0.5\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003ePathlength (mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003eAutomatic switch between 0.03\/0.05\/0.1\/0.2\/1.0 mm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eWavelength range (nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e230\/260\/280\/340\/600 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"400\" colspan=\"2\" style=\"width: 46.6228%; text-align: center;\"\u003e\n\u003cp\u003e185-910 nm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eWavelength accuracy (nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e±1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eSpectral resolution (nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e≤1.8 (FWHMat Hg 253.7 nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eAbsorbance accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003eThe greater value between: 0.002Abs (1 mm optical range), or 1% CV\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eAbsorbance precision\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e2% (at 0.64 A at 350 nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"400\" colspan=\"2\" style=\"width: 46.6228%; text-align: center;\"\u003e\n\u003cp\u003e3% (at 0.64 A at 350 nm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003ePedestal minimum test concentration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e2 ng\/μl dsDNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003ePedestal maximum test concentration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e27500 ng\/μl dsDNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eTest time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"186\" colspan=\"1\" style=\"width: 25.7143%; text-align: center;\"\u003e \u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"2\" style=\"width: 46.6228%; text-align: center;\"\u003e\n\u003cp\u003e≤ 5 sec \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"37\" rowspan=\"4\" style=\"width: 9.20635%; text-align: center;\"\u003eCuvette\u003c\/td\u003e\n\u003ctd width=\"148\" style=\"width: 15.7143%; text-align: center;\"\u003e\n\u003cp\u003eHeating temperature (℃)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e37±0.5℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"202\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e37±0.5℃\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"37\" style=\"width: 15.7143%; text-align: center;\"\u003e\n\u003cp\u003eStirring speed (RPM)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"148\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e10-900 RPM 10-speed adjustable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e10-900 RPM 10-speed adjustable\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"37\" style=\"width: 15.7143%; text-align: center;\"\u003e\n\u003cp\u003eAbsorbance range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"148\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e0-1.5A (10 mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e0-1.5A (10 mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"37\" style=\"width: 15.7143%; text-align: center;\"\u003e\n\u003cp\u003eMinimum test concentration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"148\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e0.2 ng\/μl dsDNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003eNone\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e0.2 ng\/μl dsDNA\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eDisplay\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e7-inch, 1280*800 pixel color display, capacitive touch screen, open for gesture operation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eOperating System\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003eAndroid\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eInternal storage space\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003e8 GB\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eData Interface\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"562\" colspan=\"3\" style=\"width: 72.3371%; text-align: center;\"\u003e\n\u003cp\u003eUSB, WIFI\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"400\" colspan=\"2\" style=\"width: 46.6228%; text-align: center;\"\u003e\n\u003cp\u003eAC110V-220V, 50Hz\/60Hz (power adapter)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\" colspan=\"2\" style=\"width: 24.9206%; text-align: center;\"\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"162\" style=\"width: 25.7143%; text-align: center;\"\u003e\n\u003cp\u003e2.3 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"198\" style=\"width: 24.6032%; text-align: center;\"\u003e\n\u003cp\u003e2.2 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"202\" style=\"width: 22.0196%; text-align: center;\"\u003e\n\u003cp\u003e2.3 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cp\u003e\u003cvideo style=\"width: 600px; height: 300px;\" controls=\"controls\"\u003e\n     \u003csource type=\"video\/mp4\" src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/6f3c477ebde144c59030d3028c672f49.mp4\"\u003e\u003c\/video\u003e\u003c\/p\u003e","brand":"Tiangen","offers":[{"title":"OSE-260-03","offer_id":44751783264437,"sku":"OSE-260-03","price":8034.0,"currency_code":"USD","in_stock":true},{"title":"OSE-260-05","offer_id":44751783297205,"sku":"OSE-260-05","price":10094.0,"currency_code":"USD","in_stock":true},{"title":"OSE-260-06","offer_id":44751783329973,"sku":"OSE-260-06","price":11124.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/20608e25-2231-4f51-8de2-05e4592c9ad5.jpg?v=1732884570"},{"product_id":"tgreen-transilluminator-1","title":"TGreen Transilluminator","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eTGreen Transilluminator adopts LED blue light source, amber filter and 470-520 nm excitation light material, which can be used for observation and cutting of gels loaded with GFP protein, or nucleic acid stained with a variety of safety dyes\/ EB. The TGreen Transilluminator can achieve perfect gel observation and cutting effect with no ultraviolet radiation, and provide a safe and humanized laboratory environment.\u003c\/p\u003e\n\u003cp\u003eThis instrument can also be applied to other fluorescence observation with excitation wavelengths of 470-520 nm, such as proteins, small animals and plants with GFP tag.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e High sensitivity: When used with GeneGreen, as low as 0.5 ng (1000 bp) dsDNA can be observed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafe: Blue light source has no damage to human body, gel and sample.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide application range: Compatible fluorescent dyes include GeneGreen, GelRed, GelGreen, SYBR Green I, SYBR Safe, Goldview, SYBR Gold, SYPRO Ruby, SYPRO Orange, SYPRO Tangerine, eGFP, Cy2, FITC, EB etc.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLong service life: The service life of LED lamps is 50,000 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumanization: Multi-angle rotation of filter facilitates gel cutting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 90%; border-collapse: collapse;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eOSE-470\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eOSE-470L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eDimension (DxWxH)\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e210 mmx210 mmx30 mm\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e280 mmx340 mmx80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e2.3 kg\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eTransmission light source\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eBlue LED, wavelength 470 nm\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eBlue LED, wavelength 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eSensitivity\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e0.5 ng (1000 bp) DNA\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e0.5 ng (1000 bp) DNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eObservation area (DxW)\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e120 mmx70 mm\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003e200 mmx160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003ePower adapter\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eDC 12 V,2.5 A\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eDC 12 V, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eAdjustable light intensity\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"width: 33.3333%; height: 3px; text-align: center; vertical-align: middle;\"\u003eStrong\/Weak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eOptional Matching Consumables\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eGel Cutter (OSE-GC)\u003c\/p\u003e\n\u003cp\u003eWith TIANGEN's unique Gel Cutter (OSE-GC), gel-cutting is no longer troublesome. With a simple press and push, The gel block can be directly transfer to the EP tube, and the whole gel-cutting process can be completed.\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/20201104091956_75785_600x600.jpg?v=1741594428\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003ch2 style=\"text-align: start;\"\u003eDocuments\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/OSE-470-TGreen_Transilluminator-OS221024.pdf?v=1741595576\" type=\"application\/pdf\" target=\"_blank\"\u003e\u003cstrong\u003eOSE-470-TGreen Transilluminator-OS221024\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv id=\"display-search-keyword\" style=\"display:none\"\u003etransil\u003c\/div\u003e","brand":"Tiangen","offers":[{"title":"OSE-470","offer_id":45165860257973,"sku":"","price":1020.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_ae1a6d1e-a46c-469e-982d-87f980da3dad.jpg?v=1741595095"},{"product_id":"chemi-dog-5200t-imaging-system","title":"Chemi Dog 5200T Imaging System","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Chemi Dog 5200T Imaging System is a high-performance chemiluminescence and protein gel imaging system designed for sensitive detection of Western blot signals and routine gel documentation. Engineered for research laboratories, it combines ultra-high sensitivity imaging, intelligent automation, and a compact benchtop design to deliver reliable and reproducible results.\u003c\/p\u003e\n\u003cp\u003eEquipped with an advanced scientific-grade optical system and automatic aperture control, the Chemi Dog 5200T adapts seamlessly to different imaging modes. Its intelligent sample tray recognition system enables fully automated image acquisition with a single touch, minimizing user intervention while maximizing imaging consistency and data quality.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 90%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; vertical-align: middle; width: 50%;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; vertical-align: middle; width: 50%;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eProduct Model\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eChemi Dog 5200T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eApplications\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eChemiluminescence Imaging, Protein Gel Imaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eCamera System\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eScientific research-grade ultra-clear optical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eImaging Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003e6.0 Megapixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eBit Depth\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003e65,536 (16-bit grayscale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eLED Excitation Source\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eTrans-white, Epi-white\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eTransilluminator\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eAutomatic control sample platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eMaximum Imaging Area\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003e12 × 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eSample Trays\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eAutomatic recognition of White Tray and Blot Tray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eTouch Screen\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003e12.1-inch multi-touch display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003eInstrument Dimensions (L × W × H)\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 50%; vertical-align: middle;\"\u003e40 × 45 × 42 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-High Sensitivity Detection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOptimized for low-abundance protein detection in chemiluminescent Western blot applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScientific-Grade Optical System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHigh-quality optics ensure sharp images, low background noise, and accurate signal quantification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Automation Workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAutomatic aperture adjustment and sample tray recognition enable one-click image acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Imaging Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports chemiluminescence imaging as well as visible-light protein gel documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Touchscreen Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBuilt-in 12.1\" multi-touch screen allows intuitive operation without an external computer.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Benchtop Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSpace-saving footprint suitable for individual labs, shared core facilities, and teaching laboratories.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWestern blot chemiluminescence imaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtein gel documentation (SDS-PAGE, native PAGE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBlot membrane visualization and cutting guidance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine protein expression and validation studies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAcademic research and biotechnology laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"abclonal","offers":[{"title":"Default Title","offer_id":52209705189557,"sku":"chemi dog 5200T","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/640_eb97f081-2a13-44b5-9a1d-d588b79b030f.jpg?v=1770109664"},{"product_id":"dph100-benchtop-classical-series-single-parameter","title":"DPH100 BENCHTOP – Classical Series (Single Parameter)","description":"\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 90%;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003epH\/mV, ℃ | mV (ORP), ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003epH Measurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(-2.00 ~ 20.00) pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.01 pH ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e1, 2, or 3 points automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003epH ATC Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(0.0 ~ 100.0) ℃ \/ (32.0 ~ 212.0) °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eORP Measurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(-1999.9 ~ +1999.9) mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0.1 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.1% F.S ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eConductivity Measurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eConductivity ATC Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Measurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Saturation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Automatic Barometric Pressure Compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Automatic Temperature Compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eDO Manual Salinity Compensation\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTemperature Measurement Range\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e(0.0 ~ 100.0) ℃ \/ (32.0 ~ 212.0) °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e±0.2 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eData Export\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eFlash disk \/ Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eDC 12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"text-align: center;\"\u003eTest Kit\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eMeter; Plastic ATC pH probe D201T; pH buffer solution: pH 4.00 \/ 7.00 \/ 10.01, 50 mL each; Power adaptor: 1 pc; Flexible probe holder DF01: 1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-res 7″ display screen with white backlight, easy to read\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic calibration, ATC measurement, parameter setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic reading stable indication, calibration indication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData storage: 450 readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData export: Flash disk \/ Wireless printer (the printer is optional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipped with a flexible probe holder and pH buffer solutions for convenient use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection class: IP54\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompoments\u003c\/h2\u003e\n\u003cp\u003e1.DPH100 Meter\u003c\/p\u003e\n\u003cp\u003e2.D201T ATC plastic pH probe\u003c\/p\u003e\n\u003cp\u003e3.pH buffer solution: pH4.00\/7.00\/10.01, 50mL, one for each\u003c\/p\u003e\n\u003cp\u003e4.DF01 Flexible probe holder: 1pc\u003c\/p\u003e\n\u003cp\u003e5.DA01 Power adaptor\u003c\/p\u003e","brand":"DLAB","offers":[{"title":"DPH100","offer_id":52340984840373,"sku":"4090010200","price":339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Classicalseries.jpg?v=1773302512"},{"product_id":"eurolabworkstation-ifa-for-in-vitro-diagnostic-use","title":"EUROLabWorkstation IFA Full Automation of Indirect Immunofluorescence","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n    \n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROLabWorkstation IFA\u003c\/strong\u003e heralds a new era in IFA automation. With this new development EUROIMMUN enables fully automated and standardized processing with highest capacity and highest efficiency for laboratories with high sample throughput. Up to 750 substrate fields and more than 700 samples can be analyzed at high throughput with just one worklist. The system was developed by EUROIMMUN with a focus on data integrity and minimisation of manual processes. This ensures brilliant fluorescence signals without background for the automatically mounted slides.\u003c\/p\u003e\n            \u003cp\u003eThe software can be operated comfortably and intuitively via a touch screen and guides the user through the entire process. Complete traceability is guaranteed at all times, since the matrix codes of the slides and the barcodes of samples, reagents and accessories are automatically detected in each step of the process.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated processing of EUROIMMUN immunofluorescence tests from primary sample to mounted slide\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHighest capacity of up to 750 substrate fields and more than 700 samples in a single worklist\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHighest efficiency due to 10 washable pipetting needles and complementary accessories, as well as separation of pipetting and transport steps for flexible time management\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible workflows owing to freely selectable loading of the 45 tracks with samples, reagents and dilution plates\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eBrilliant fluorescence signals – each substrate field is washed without the risk of cross contamination using directed liquid flow in a standardised and gentle procedure\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum, CSF, and DBS\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 700 samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 750 reaction fields (combination of slides with 10 and 50 reaction fields possible)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eParameter Capacity per Run\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 75\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Washing Unit\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOne each for slides with 10 and 50 reaction fields\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eReagent Tray Washing Unit\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 dispensing needles and 11 aspiration needles\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 200 tests per hour\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volume\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 μl – 1100 μl, 1 μl increments\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eAutomated registration of samples, reagents, dilution plates, slides, reagent trays and cover glass holders\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eTouchscreen PC with EUROLabWorkstation IFA software\u003cbr\u003eMicrosoft® Windows® 10 LTSB\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM via EUROLabOffice\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e114.96 × 31.93 × 33.82 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e992.08 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWorkflow optimization\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e45 sample and reagent tracks for freely selectable loading | Slides with 10 and 50 reaction fields | Spatial separation of liquid handling and incubation | Fully automated washing and mounting.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_576a7ac2-8a55-4962-b952-def1a1a0c207.jpg?v=1774228471\" alt=\"Workflow Optimization\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePrecise \u0026amp; Efficient Pipetting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e10 coated stainless steel needles | Precision pumps | Optimised routes | Liquid level detection | Multishot function for reagents.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features02.jpg?v=1774228471\" alt=\"Pipetting Efficiency\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eInnovative Washing Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eControlled liquid flow | Two integrated washing units | Reagent tray cleaning | Automatic mounting medium dispensing.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features03.jpg?v=1774228471\" alt=\"Washing Technology\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eConvenient Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eTouch-screen PC | Intuitive GUI | Real-time flow display | Software-supported maintenance.\u003c\/p\u003e\n                \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ifa_features04.jpg?v=1774228471\" alt=\"Operation\" style=\"width: 100%; border-radius: 4px; height: auto;\"\u003e\n            \u003c\/div\u003e\n          \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eProcess Status Overview\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eDetailed status on run times, resources and slides; ID-based memory; Exact pending time.\u003c\/p\u003e\n        \n            \u003c\/div\u003e\n          \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eProcess Security A-Z\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eMulti-user rights; Transparent traceability; Gapless allocation of samples and reagents.\u003c\/p\u003e\n        \n            \u003c\/div\u003e\n        \u003c\/div\u003e\n\n       \n  \n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"column-count: 1; gap: 30px;\"\u003e\n            \u003cp style=\"margin-bottom: 20px; font-style: italic;\"\u003eThe EUROLabWorkstation IFA is designed for fully automated indirect immunofluorescence (IFA) workflows in high-throughput environments...\u003c\/p\u003e\n            \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Automated detection of ANA, ANCA, anti-dsDNA.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e High-throughput viral and bacterial screening.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical Routine Testing:\u003c\/strong\u003e Improved turnaround for hospital diagnostic labs.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eReference Laboratories:\u003c\/strong\u003e Standardized workflows \u0026amp; LIS integration.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eResearch \u0026amp; Translational:\u003c\/strong\u003e Large-scale immunological studies.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eEpidemiological Surveillance:\u003c\/strong\u003e Rapid population-level antibody screening.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e End-to-end processing with minimal human error.\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Platforms:\u003c\/strong\u003e \u0026gt;200 tests per hour capacity.\u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375729864885,"sku":"EU-LAB-ELWIF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROLabWorkstation_IFA_for_In_Vitro_Diagnostic_Use.jpg?v=1774228832"},{"product_id":"europattern-microscope-for-in-vitro-diagnostic-use","title":"EUROPattern Microscope Computer-aided Immunofluorescence Microscopy (CAIFM)","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROPattern Suite\u003c\/strong\u003e automates immunofluorescence microscopy, enhancing diagnostic result reporting and seamlessly integrating with EUROLabOffice for flexible laboratory workflows.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eDesigned for high-throughput environments, the system minimizes manual handling and enables standardized IFA diagnostics with exceptional speed and efficiency.\u003c\/p\u003e\n            \u003cp\u003eThe suite combines a fully automated microscope with a slide magazine (up to 500 substrate fields per run) and advanced pattern recognition software for accurate classification and evaluation.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated microscopy with on-screen reporting system, eliminating the need for a darkroom\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003ePattern recognition and titer determination for multiple substrates\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eExtended walk-away time with automated processing of up to 500 positions per run\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh-throughput imaging with over 250 fluorescence images evaluated per hour\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable traceability through automatic slide identification via matrix codes\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003ePower Supply\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e110–240 V, 60 W, 50\/60 Hz\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eLED Light Source (Constant)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e620–630 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ecLED Light Source (Constant Excitation)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e460–490 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e20.08 × 25.98 × 33.46 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e180.78 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Microscopy\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomates the entire IFA imaging workflow, eliminating manual microscopy and removing the need for a darkroom.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePattern Recognition \u0026amp; Titer Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eIntegrated software enables automatic fluorescence pattern classification and quantitative titer determination.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh-Throughput Imaging\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eCaptures and evaluates over 250 fluorescence images per hour for efficient large-scale diagnostics.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLarge Capacity Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses up to 500 substrate fields per run, enabling extended walk-away automation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eSoftware Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSeamlessly integrates with EUROLabOffice for flexible data management and reporting workflows.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eTraceability \u0026amp; Reliability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomatic slide identification via matrix codes ensures full traceability and reduces human error.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReproducible Results\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eMinimizes manual variability, delivering consistent and standardized immunofluorescence diagnostics.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Detection and classification of autoantibodies using IFA (e.g., ANA, ANCA).\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunology Laboratories:\u003c\/strong\u003e High-throughput routine screening and confirmation of fluorescence-based tests.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eIn Vitro Diagnostic (IVD) Workflows:\u003c\/strong\u003e Standardized automated microscopy for regulated diagnostic environments.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e Evaluation of antibody responses using fluorescence-based assays.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e Integration into LIS for automated interpretation, reporting, and data management.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch \u0026amp; Translational Studies:\u003c\/strong\u003e Fluorescence pattern analysis and antibody profiling in immunology research.\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375743955125,"sku":"EU-MIC-EPML","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROPattern_Microscope_for_In_Vitro_Diagnostic_Use.jpg?v=1774231335"},{"product_id":"europattern-microscope-live-convenient-immunofluorescence-microscopy","title":"EUROPattern Microscope Live Convenient Immunofluorescence Microscopy","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eEUROPattern Microscope Live\u003c\/strong\u003e is a fully automated immunofluorescence system delivering ultra-fast image processing in just 2 seconds per image. The intuitive touchscreen interface enables real-time zooming and positioning during live microscopy, while supporting simultaneous multi-user viewing without the need for a discussion bridge.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eUp to 50 reaction fields can be processed per run. Equipped with a 20× objective, high-resolution camera, and premium optical components, the system enables automated viewing of a wide range of substrates with exceptional clarity.\u003c\/p\u003e\n            \u003cp\u003eAdvanced laser autofocus, a self-regulating long-life cLED excitation source, and automated calibration using an integrated fluorescence standard ensure consistent signal intensity and reproducible results. Its compact, opaque design allows operation in any laboratory environment regardless of lighting conditions.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated image acquisition and on-screen analysis, eliminating the need for a darkroom\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eUltra-fast processing speed of 2 seconds per image\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eUser-friendly live microscopy with multi-touch navigation and zoom\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable traceability through automatic slide identification via matrix codes\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eSimultaneous multi-user viewing without external discussion systems\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003ePower Supply\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e110–240 V, 60 W, 50\/60 Hz\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ecLED Light Source (Constant Excitation)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e460–490 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e15.94 × 20.87 × 15.35 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e99.21 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUltra-Fast Imaging\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses images in just 2 seconds, enabling rapid and efficient immunofluorescence workflows.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomates image capture, focusing, and calibration for consistent and reproducible results.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLaser Autofocus Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eIntegrated laser-based autofocus ensures precise focusing and enhanced image clarity.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh-Resolution Optics\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eCombines a 20× objective, high-resolution camera, and premium optics for accurate substrate visualization.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStable Fluorescence Illumination\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSelf-regulating cLED light source and automated calibration ensure uniform signal intensity.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLive Touchscreen Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eMulti-touch interface enables real-time zooming, navigation, and intuitive image interaction.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMulti-User Viewing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports simultaneous on-screen viewing by multiple users without additional hardware.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eTraceability \u0026amp; Data Integrity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomatic matrix code recognition ensures reliable slide identification and tracking.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCompact Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eOpaque housing enables operation in standard lab environments without light restrictions.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eIFA Analysis:\u003c\/strong\u003e Real-time visualization and evaluation of fluorescence signals in immunoassays.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Research:\u003c\/strong\u003e Detection and analysis of autoantibody patterns on cellular substrates.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Studies:\u003c\/strong\u003e Observation of pathogen-specific antibody binding via fluorescence assays.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eCell Biology:\u003c\/strong\u003e Investigation of cellular structures, antigen expression, and protein localization.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eHigh-Throughput Screening:\u003c\/strong\u003e Rapid and consistent imaging across large sample sets.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eCollaborative Research:\u003c\/strong\u003e Enables simultaneous multi-user image review without additional systems.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eWorkflow Optimization:\u003c\/strong\u003e Reduces manual workload and improves efficiency in fluorescence microscopy workflows.\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375753130165,"sku":"EU-MIC-EPM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROPattern_Live_Microscope_Automated_Immunofluorescence_Imaging-da96-41e3-97f0-6b65d4d5da80.jpg?v=1774232042"},{"product_id":"eurostar-iii-plus-controlled-light-intensity-for-reliable-ifa-diagnostics","title":"EUROStar III Plus LED Fluorescence Microscope – Controlled Light Intensity for Reproducible IFA Imaging","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eEUROStar III Plus\u003c\/strong\u003e LED fluorescence microscope is specifically designed for indirect immunofluorescence applications. A camera can be directly connected to the integrated photo tube for seamless digital image acquisition, while a 50\/50 beam splitter enables simultaneous viewing through ocular and camera without switching.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe system supports digital image capture and analysis via EUROPicture software. An optional immunofluorescence positioning system (IF-PS) minimizes positioning errors and improves result accuracy.\u003c\/p\u003e\n\u003cp\u003eEquipped with a halogen lamp for transmitted light microscopy (bright and dark field) and upgrade capability for phase contrast, the microscope offers flexible functionality for diverse laboratory applications.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eRegulated LED ensures constant fluorescence excitation for reproducible results\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eLong lifespan exceeding 50,000 hours with low power consumption\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eMercury-free design for environmentally friendly operation\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDigital imaging with optional camera and EUROPicture software\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e50\/50 beam splitter enables simultaneous ocular and camera observation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Specifications --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eLED Light Source (Excitation)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e460–490 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Life\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eMinimum 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e12 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e7.36 × 16.14 × 17.68 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e21.16 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStable LED Excitation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eRegulated 460–490 nm LED ensures consistent fluorescence intensity and reproducible results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUltra-Long Lifespan\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eOver 50,000 hours of operation reduces maintenance and eliminates frequent lamp replacement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eInstant Illumination\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eProvides full light intensity immediately after startup with low energy consumption.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMercury-Free Design\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eEnvironmentally friendly system without hazardous mercury lamps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDigital Imaging Integration\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eDirect camera connection enables seamless image capture and analysis with EUROPicture software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003e50\/50 Beam Splitter\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eAllows simultaneous viewing through ocular and camera without switching.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIF Positioning System (Optional)\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eReduces positioning errors and improves accuracy in microscopy result documentation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDual-Mode Microscopy\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eIncludes halogen lamp for bright and dark field microscopy with upgrade capability for phase contrast.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eIFA Analysis:\u003c\/strong\u003e Visualization of antibody-antigen interactions in immunofluorescence assays.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAutoimmune Research:\u003c\/strong\u003e \u003cstrong\u003eIdentification\u003c\/strong\u003e and analysis of ANA, ANCA, and related fluorescence patterns.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eLaboratory Imaging:\u003c\/strong\u003e Routine fluorescence microscopy with reliable and standardized image acquisition.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eDigital Documentation:\u003c\/strong\u003e Image capture, storage, and analysis using EUROPicture software.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCell \u0026amp; Tissue Analysis:\u003c\/strong\u003e Observation of fluorescently labeled cells, tissues, and substrates.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eEducation \u0026amp; Training:\u003c\/strong\u003e Ideal for teaching fluorescence microscopy with real-time digital visualization.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375769809077,"sku":"EU-MIC-ES3P","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROStar_III_Plus_Controlled_Light_Intensity_for_Reliable_IFA_Diagnostics.jpg?v=1774232908"},{"product_id":"sprinter-xl-fast-and-reliable-ift-automation-for-medium-and-high-throughput","title":"Sprinter XL Fast and Reliable IFT Automation for Medium and High Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eWith the \u003cstrong\u003eSprinter XL\u003c\/strong\u003e, EUROIMMUN provides a flexible solution for fully automated processing of immunofluorescence tests for medium- and high-throughput laboratories. The system performs sample identification, dilution, and transfer, as well as all washing and incubation steps.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eSprinter XL can also be configured as a combination system for additional ELISA processing, enabling integrated automation of multiple assay workflows on a single platform.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible automation for ELISA and immunofluorescence tests on one device\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable traceability with integrated barcode reader and optional slide matrix code identification\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eEfficient carryover-free pipetting using four washable needles, two independent robot arms, and optimized workflow calculation\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eUser-friendly data communication with LIS or EUROLabOffice for simplified routine laboratory workflows\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConfigurable capacity for up to 160 or 240 samples and up to 30 slides or 6 ELISA plates per run\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSerum, plasma and CSF\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 160 or 240 samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 30 slides (combination of slides with 10 and 50 reaction fields possible) or up to 6 ELISA plates\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volume\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 μl – 1000 μl, 1 μl increments\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eAutomated registration of samples, optional automated registration of slides\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e46.85 × 33.46 × 27.95 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e330.69 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated IFT \u0026amp; ELISA Processing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated system enables seamless automation of immunofluorescence and ELISA workflows within a single platform.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh Throughput Flexibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports up to 160 or 240 samples and up to 30 slides or 6 ELISA plates per run for scalable laboratory operations.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBuilt-in barcode reader and optional slide matrix code recognition ensure accurate sample tracking and data integrity.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePrecision Pipetting Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eFour washable needles and dual robotic arms deliver carryover-free pipetting with optimized workflow efficiency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eComprehensive Workflow Automation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomates sample identification, dilution, transfer, washing, and incubation steps to minimize manual intervention.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Integration \u0026amp; Smart Data Handling\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompatible with LIS and EUROLabOffice for streamlined data communication and laboratory management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eConfigurable System Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eFlexible instrument configuration adapts to varying laboratory throughput and application requirements.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAutomated IFT\/IFA Processing:\u003c\/strong\u003e Automated processing of indirect immunofluorescence tests in clinical laboratories.\u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Diagnostics:\u003c\/strong\u003e Supports autoimmune and infectious disease testing in medium- to high-volume environments.\u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eELISA Workflow Automation:\u003c\/strong\u003e Enables integrated ELISA assay processing and workflow consolidation on one system.\u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eRoutine Diagnostic Laboratories:\u003c\/strong\u003e Ideal for laboratories requiring standardized, traceable, and reproducible workflows.\u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eMedium- to High-Volume Sample Processing:\u003c\/strong\u003e Designed for efficient handling of larger daily testing demands.\u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eWorkflow Optimization:\u003c\/strong\u003e Reduces manual handling while improving operational consistency and reproducibility.\u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375789338805,"sku":"EU-ANA-SXL","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Sprinter_XL_Fast_and_Reliable_IFT_Automation_for_Medium_and_High_Throughput.jpg?v=1774234796"},{"product_id":"if-sprinter-fast-and-reliable-ift-automation-for-low-and-medium-throughput","title":"IF Sprinter Fast and Reliable IFT Automation for Low and Medium Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eWith the \u003cstrong\u003eIF Sprinter\u003c\/strong\u003e, EUROIMMUN US offers a solution for fully automated processing of immunofluorescence tests for small- and medium-volume laboratories. The system performs sample identification, dilution, transfer, washing, and incubation steps.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible system for fully automated processing of immunofluorescence tests\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliability and traceability via integrated barcode reader and optional slide matrix code identification\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eEfficient carryover-free pipetting using a washable pipetting needle\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eSimplified laboratory workflows through user-friendly data communication with LIS or EUROLabOffice\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCapacity for up to 96 samples and 15 slides per run\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSerum, plasma and CSF\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 96 samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSlide Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 15 slides (combination of slides with 10 and 50 reaction fields possible)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volume\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 μl – 1000 μl, 1 μl increments\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eAutomated registration of samples, optional automated registration of slides\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e25.59 × 27.56 × 29.53 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e110.23 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated IFT Processing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eComplete automation of immunofluorescence assays including identification, dilution, transfer, washing, and incubation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Throughput\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports up to 96 samples and 15 slides per run for small- to medium-volume laboratories.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eTraceability System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eIntegrated barcode reader with optional slide matrix code recognition for reliable sample identification.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCarryover-Free Pipetting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eWashable pipetting needle ensures precise liquid handling without contamination.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS \u0026amp; EUROLabOffice Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eUser-friendly data communication supports streamlined workflow integration and laboratory management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWorkflow Simplification\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSimplifies routine laboratory processes through automated operations and integrated data handling.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eBroad Sample Compatibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports serum, plasma, and CSF for diverse immunofluorescence applications.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Diagnostics:\u003c\/strong\u003e Processing of ANA, ENA, and other IFA assays.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Detection of pathogen-specific antibodies using immunofluorescence techniques.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Routine Laboratories:\u003c\/strong\u003e Suitable for low- to medium-throughput environments requiring standardized workflows.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eSerological Screening:\u003c\/strong\u003e Processing of serum, plasma, and CSF samples for antibody analysis.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e Replacement of manual IFA workflows to reduce labor intensity and improve consistency.\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375792386229,"sku":"EU-ANA-IFS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/IF_Sprinter_Fast_and_Reliable_IFT_Automation_for_Low_and_Medium_Throughput.jpg?v=1774235444"},{"product_id":"uniqo-160-fully-automated-ifa-system-from-sample-processing-to-image-acquisition","title":"UNIQO 160 Fully Automated IFA System – from Sample Processing to Image Acquisition","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eUNIQO 160\u003c\/strong\u003e provides a complete automation solution from primary sample pipetting to automated IFA image acquisition within a single instrument.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eIn one run, this benchtop device processes up to 160 primary samples and 18 microscope slides. Samples, reagents, and slides are automatically identified and assigned via barcodes for complete traceability. Slides are protected from drying through automated mounting and cover-slipping after incubation.\u003c\/p\u003e\n            \u003cp\u003eThis device integrates a high-quality microscope with automatically changing objectives (4x, 10x, 20x) for fluorescence image acquisition across the entire worklist.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eOperation\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eFull HD touch-screen monitor, 15 inches\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eCommunication with LIS\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eCompatible\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eElectrical Data\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100–240 V AC\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions \/ Weight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1200 mm (47 in) × 900 mm (35 in) × 700 mm (27.5 in) (W × D × H, without accessories)\u003cbr\u003eApprox. 150 kg (330 lbs)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n            \n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Three-Needle System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eEfficient pipetting of samples and reagents as well as washing of slides.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh Capacity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses 160 IFA samples, 288 dilutions, and 18 slides per run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFull Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eBarcode scanners enable identification of samples, reagents, and slides.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Loading\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports up to 20 controls, 4 dilution buffers, and 9 bottles of conjugate and mounting medium.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated Imaging\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eFluorescence image recording with autofocus and automatically changing objectives (4x, 10x, 20x).\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eIFA Processing:\u003c\/strong\u003e Automated processing of indirect immunofluorescence assays from sample pipetting to image acquisition.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eHigh-Throughput Laboratories:\u003c\/strong\u003e Suitable for clinical and research laboratories requiring standardized IFA workflows.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Diagnostics:\u003c\/strong\u003e Detection of ANA, ANCA, and related markers using fluorescence-based methods.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Serology:\u003c\/strong\u003e Immunofluorescence slide-based antibody testing.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eCentralized Laboratories:\u003c\/strong\u003e End-to-end automation with minimal manual intervention and reduced human error.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eTraceability \u0026amp; Data Integrity:\u003c\/strong\u003e Barcode-based tracking of samples and reagents.\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eDigital Microscopy:\u003c\/strong\u003e Automated image capture, analysis, and reporting integration (LIS compatibility).\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375798350005,"sku":"EU-ANA-U160","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/UNIQO_160_Fully_Automated_IFA_System_from_Sample_Processing_to_Image_Acquisition.jpg?v=1774236167"},{"product_id":"eurolabworkstation-elisa-fully-automated-user-friendly-elisa-processing","title":"EUROLabWorkstation ELISA Fully Automated, User-friendly ELISA Processing","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROLabWorkstation ELISA\u003c\/strong\u003e is a fully automated complete solution for processing ELISA kits in laboratories with high sample throughput. The system was developed by EUROIMMUN with a focus on efficiency and flexibility, in order to accommodate the ever increasing sample numbers and changing dynamics in the routine laboratory.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eTen washable needles, complementary accessories and a separate robotic arm for handling the microplates enable unparalleled sample throughput. State-of-the-art, intuitive software guides the user graphically through all work steps.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eFully automated processing of ELISA from primary sample to result\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eHighest capacity of up to 15 microplates and up to 700 samples in a single worklist\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eHighest throughput of up to 200 tests per hour due to fast pipetting of samples and reagents using 10 pipetting channels and efficient processing of microplates\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eFlexible open system for ELISA tests from different manufacturers\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eMinimal hands-on time and high integrity of results due to use of bar\/matrix codes to identify samples, reagents and accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Specifications --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum, CSF, and DBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 700 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePlate Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eParameter Capacity per Run\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eIncubators\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eShakable Incubators\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026gt; 200 tests per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e5 μl – 1100 μl, 1 μl increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e2 integrated code scanners for identification of samples, reagents, dilution plates and ELISA plates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eTouchscreen PC with EUROLabWorkstation ELISA software\u003cbr\u003eMicrosoft® Windows® 10 LTSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM interface, bi-directional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e114.96 × 31.93 × 33.82 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e992.08 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eOptimize workflows and obtain maximum process efficiency\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eMechanical separation of liquid handling and plate transport allows simultaneous operations\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e10 needles provide unrivaled performance\u003c\/p\u003e\n\u003cimg style=\"width: 100%; border-radius: 4px; height: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_7a9d6df4-ec90-4c97-ab9a-acbe7d83072b.jpg?v=1774236816\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCustomize system design for different workflow needs\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eIndividual configuration of functionality and operating volume\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003e45 tracks for loading samples and reagents\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eUp to 8 temperature-controlled incubators\u003c\/p\u003e\n\u003cimg style=\"width: 100%; border-radius: 4px; height: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_7ed3f109-ec5e-442d-b2cb-930271e6c1a8.jpg?v=1774236816\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReduce hands-on time and increase process reliability\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eIntelligent software guides the operator through all steps\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eIntuitive graphical user interface for simple run management\u003c\/p\u003e\n\u003cimg style=\"width: 100%; border-radius: 4px; height: auto;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/2_f12aab4f-b945-460b-a5ff-42c1129f0e55.jpg?v=1774236816\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eOverview process status and directly access all significant information\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eDetailed dashboard with resource overview, plate status and pending actions\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eInspect ELISA plates and evaluate results without delay\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eContinuous and immediate access to ELISA plates during active run\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eNo need to interrupt running processes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eObtain precise and correct results\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 10px;\"\u003eCoated stainless steel needles and precision pumps guarantee optimal pipetting precision\u003c\/p\u003e\n\u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eLiquid level detection allows for reliable pipetting processes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"column-count: 1; gap: 30px;\"\u003e\n\u003cp style=\"margin-bottom: 20px; font-style: italic;\"\u003eThe EUROLabWorkstation ELISA is designed for high-throughput laboratories requiring fully automated, standardized ELISA processing with minimal hands-on time and maximum reproducibility. Typical applications include:\u003c\/p\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical diagnostics laboratories:\u003c\/strong\u003e for large-scale serological testing (e.g., infectious diseases, autoimmune markers, allergy testing)\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHospital and reference labs:\u003c\/strong\u003e Handling high daily sample volumes with strict traceability requirements\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eBiotechnology and pharmaceutical research:\u003c\/strong\u003e for biomarker screening, immunoassay development, and validation workflows\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eBlood banks and epidemiological studies:\u003c\/strong\u003e Requiring reliable, high-capacity ELISA processing\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eAcademic and research institutions:\u003c\/strong\u003e Performing routine ELISA-based assays with scalable throughput\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eContract research organizations (CROs):\u003c\/strong\u003e Supporting high-throughput assay processing and sample analysis\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375843799221,"sku":"EU-LAB-ELW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROLabWorkstation_ELISA_Fully_Automated_User-friendly_ELISA_Processing.jpg?v=1774242891"},{"product_id":"euroimmun-analyzer-i-efficient-elisa-automation-for-medium-to-high-throughput","title":"EUROIMMUN Analyzer I Efficient ELISA Automation for Medium to High Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROIMMUN Analyzer I\u003c\/strong\u003e is an open system for fully automated ELISA processing of up to 7 microplates and 180 patient samples in a single run. In combination with EUROIMMUN ELISAs, it enables fast, simple, and secure routine operation through automatic recognition and allocation of reagents, as well as QC data import via Data Matrix codes.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eAn optionally available climate control unit ensures constant incubation conditions, regardless of fluctuating or elevated laboratory temperatures. The EUROIMMUN Analyzer I is designed for medium to high sample volumes.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated ELISA processing for medium to high sample volumes with minimal manual input\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh reliability and traceability through automatic barcode identification of patient samples and ready-to-use reagents\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFast processing of up to 70 tests per hour, with up to 7 plates and 180 samples per run\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConvenient software operation, including scanning of QC certificates with a 2D hand barcode scanner\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum, CSF and stool\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePatient Sample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 180 samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePlate Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 7\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eParameter Capacity per Run\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 54\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eShakeable Incubators\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 70 tests per hour\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 10–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIntegrated code scanner for identification of samples and reagents\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eMicrosoft® Windows® 10 Enterprise 2019 LTSC (64 Bit)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM interface, bi-directional\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e43.31 × 29.53 × 39.37 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e286.60 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated ELISA Workflow\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnd-to-end automation from sample identification to result generation minimizes manual intervention and reduces human error.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMedium to High Throughput Efficiency\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProcesses up to 7 microplates and 180 patient samples per run, supporting high-volume laboratory operations.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFast Testing Performance\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAchieves throughput of up to 70 tests per hour, enabling rapid turnaround for routine diagnostics.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated barcode scanning ensures secure identification of samples, reagents, and consumables for full workflow traceability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eSmart Reagent \u0026amp; QC Management\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic recognition of reagents and Data Matrix-based QC data import enhance accuracy and compliance.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eOptional Climate Control Stability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eMaintains consistent incubation conditions regardless of ambient lab temperature fluctuations.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Open System Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompatible with EUROIMMUN ELISA kits while allowing adaptable workflow configurations.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUser-Friendly Software Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntuitive operation with Windows-based system and 2D barcode scanner for streamlined QC and workflow management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReliable Data Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBi-directional ASTM interface enables seamless connectivity with LIS systems.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #fff; padding: 0;\"\u003e\n            \u003cp style=\"margin-bottom: 20px; font-style: italic;\"\u003eThe EUROIMMUN Analyzer I is designed for laboratories requiring reliable, automated ELISA processing with medium to high throughput and strong traceability. Typical applications include:\u003c\/p\u003e\n            \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003eClinical diagnostic laboratories performing serological testing such as infectious diseases, autoimmune disorders, and allergy profiling\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003eHospital and reference laboratories managing routine ELISA workflows with moderate to high daily sample volumes\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003ePublic health and epidemiology labs conducting population-level screening and surveillance studies\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003eBiotechnology and pharmaceutical laboratories supporting biomarker analysis, assay validation, and immunoassay development\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003eBlood banks and transfusion centers requiring standardized ELISA-based screening workflows\u003c\/div\u003e\n                \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003eContract research organizations (CROs) handling high-throughput immunoassay testing services\u003c\/div\u003e\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375856021685,"sku":"EU-ANA-AI","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROIMMUN_Analyzer_I_Efficient_ELISA_Automation_for_Medium_to_High_Throughput.jpg?v=1774243837"},{"product_id":"ids-i10-and-ids-isys","title":"IDS-i10 and IDS-iSYS","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eIDS-i10\u003c\/strong\u003e and \u003cstrong\u003eIDS-iSYS Multi-Discipline Automated System\u003c\/strong\u003e are compact random access instruments for automated processing of chemiluminescence immunoassays (ChLIA) used in autoimmune, allergy, and infection diagnostics, as well as antigen detection. Continuous sample loading, and for the IDS-i10 also connection to a lab track system, allows each patient sample to be processed individually with minimal effort and short reaction times.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003ePreferred processing of emergency (STAT) samples gives laboratories with different requirements and sample volumes a high degree of flexibility in routine operation.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eRandom access instruments for batch, continuous, and STAT loading\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eMinimal calibration effort due to stored master curves\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConnection to a laboratory track system possible for the IDS-i10\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutoimmune, allergy, infection parameters, and antigen detection on one instrument\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eShort reaction times for fast and reliable results in just 25 minutes, depending on the test\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh throughput of up to 120 samples per hour\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eConvenient and reliable operation through barcode recognition of samples and test- and lot-specific information, including stored standard curve\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Material\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSerum, plasma, urine or saliva (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eNumber of Loading Positions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e120 positions for samples, calibrators and controls (6 racks with 20 positions)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eNumber of Parameters\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 15 different immunoassay cartridges\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTime to First Result\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e\u0026lt; 25 minutes (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eThroughput\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 120 tests\/hour (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePrimary tubes: 4.5 mL, 6 mL, 8.5 mL, 10 mL; secondary tubes: 5 mL; microvials: 500 μL, 2 mL\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eLuminometer\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eWavelengths from 300 to 500 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSpectrophotometer\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eSpectrophotometer with LED technology and 12 wavelength filters\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePipetting Volumes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4 μL – 300 μL (assay dependent)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIntegrated reader in sample compartment as well as for reagent cartridge barcodes\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eASTM interface, bi-directional\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1050 × 750 × 700 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e103 kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eRandom Access Flexibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports batch, continuous, and STAT loading for efficient handling of routine and urgent samples.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFast Turnaround Time\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eDelivers results in less than 25 minutes, depending on the assay, for rapid clinical decisions.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh Throughput Performance\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProcesses up to 120 tests per hour for medium- to high-volume laboratories.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMulti-Discipline Testing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports autoimmune, allergy, infection diagnostics, and antigen detection on a single platform.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMinimal Calibration Effort\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eStored master calibration curves reduce setup time and improve consistency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated barcode recognition for samples and reagents ensures workflow security and data integrity.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eContinuous Sample Loading\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports uninterrupted workflow, with optional lab track integration for the IDS-i10.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWide Sample Compatibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports serum, plasma, urine, and saliva depending on the assay requirements.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePrecision Optical System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEquipped with a luminometer and LED-based spectrophotometer for reliable signal detection.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Pipetting Range\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eHandles volumes from 4 μL to 300 μL for broad assay versatility.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunodiagnostics:\u003c\/strong\u003e Detection of autoimmune diseases through chemiluminescence immunoassays.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Testing:\u003c\/strong\u003e Quantitative and qualitative analysis of allergy-related biomarkers.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Diagnostics:\u003c\/strong\u003e Identification of infectious agents and immune responses in clinical samples.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAntigen Detection:\u003c\/strong\u003e Rapid screening and monitoring of disease-specific antigens.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eRoutine Laboratory Automation:\u003c\/strong\u003e Ideal for laboratories requiring continuous, high-throughput immunoassay processing.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eSTAT Sample Processing:\u003c\/strong\u003e Prioritized testing for emergency samples in hospital and clinical laboratory environments.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375872405685,"sku":"IDS-ANA-I10ISYS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/IDS-i10_and_IDS-iSYS.jpg?v=1774245092"},{"product_id":"euroblot-one-automated-immunoblot-workstation-solution","title":"EUROBlot One Automated Immunoblot Workstation Solution","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROBlotOne\u003c\/strong\u003e is a compact tabletop device for complete immunoblot processing. After fast, software-guided loading, the system performs sample identification and dilution, as well as all incubation and wash steps automatically.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eEight reagent channels allow combined testing from autoimmune and infection diagnostics in one run, as well as allergy testing on the same device. Incubated strips are automatically dried, photographed, and evaluated using EUROLineScan software.\u003c\/p\u003e\n            \u003cp\u003eTest requests and results can be communicated bidirectionally with an LIS or EUROLabOffice 4.0 for seamless laboratory integration.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated processing of up to 44 immunoblots in one run, from sample identification to final result\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eIntegrated drying unit for fast strip evaluation and high reproducibility\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eHigh security through automatic barcode identification of samples\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible combination of autoimmune and infection parameters in one run, with autoimmune, infection, and allergy diagnostics on one device\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eIntuitive software for secure and convenient operation\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReliable automated blot strip evaluation using EUROLineScan software\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum and CSF\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePatient Sample Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 44\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eControl Positions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTest Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e44 strips\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Tubes\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eOuter diameter 8–16 mm, height up to 100 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTraceability\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIntegrated code scanner for identification of samples\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eUser Interface\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eMicrosoft® Windows® 10 Pro\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOnline Connection\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eBi-directional via EUROLineScan\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e318.90 × 20.87 × 19.49 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e88.18 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Workflow\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnd-to-end automation from sample identification to final result for up to 44 immunoblot strips per run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Drying System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBuilt-in drying unit enables rapid strip processing and highly reproducible results.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic barcode scanning ensures secure sample identification and reduces manual errors.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMultiplex Testing Flexibility\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports combined autoimmune, infection, and allergy assays on a single device.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntelligent Software Control\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSoftware-guided operation provides secure, intuitive, and convenient workflow management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated Imaging \u0026amp; Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBlot strips are automatically photographed and evaluated with EUROLineScan software.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Connectivity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBi-directional communication with LIS or EUROLabOffice supports seamless laboratory integration.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Detection of autoantibodies for ANA, ENA, and other autoimmune markers.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Identification of pathogen-specific antibodies for viral, bacterial, and parasitic infections.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Diagnostics:\u003c\/strong\u003e Multiparametric analysis of allergen-specific antibodies in clinical samples.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Immunology Laboratories:\u003c\/strong\u003e Ideal for routine immunoblot processing with medium throughput requirements.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eReference \u0026amp; Diagnostic Labs:\u003c\/strong\u003e Automated immunoblot workflows for improved reproducibility and efficiency.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Applications:\u003c\/strong\u003e Suitable for immunoblot-based biomarker studies and assay development.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375916708021,"sku":"EU-LAB-BLO1","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROBlot_One_Automated_Immunoblot_Workstation_Solution.jpg?v=1774245924"},{"product_id":"euroblotmaster-compact-immunoblot-strip-processor","title":"EUROBlotMaster Compact Immunoblot Strip Processor","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eEUROBlotMaster\u003c\/strong\u003e and \u003cstrong\u003eEUROBlotMaster 44\u003c\/strong\u003e are compact tabletop devices for processing EUROIMMUN blot strips, including EUROLINE, EUROLINE-WB, and Western blot formats. After software-guided loading of reagents, blot strips, and samples, the devices automatically perform all incubation and wash steps, as well as dispensing of buffers, conjugates, substrate, and stop solutions.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eDifferent conjugates can be combined in a single run. The devices feature an integrated display with a membrane keyboard, eliminating the need for an additional PC.\u003c\/p\u003e\n            \u003cp\u003eOperation is simple and convenient using six keys, while daily maintenance requires no more than five minutes.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFlexible automation for all EUROIMMUN blot strips, including EUROLINE, EUROLINE-WB, and Western blot\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eStandardized processing for improved precision and reproducibility\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCombination of different conjugates on one device\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eTwo models available for up to 30 or up to 44 strips per run\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eEasy operation via menu navigation on the integrated display\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCombination of different conjugates and tests in one run\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCompact tabletop design with low space requirement\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eSample Types\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePlasma, serum and CSF\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eTest Capacity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUp to 44 strips\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eControl Positions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e20.47 × 12.20 × 9.84 in\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e31.97 lbs\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Immunoblot Automation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompatible with EUROIMMUN blot strips including EUROLINE, EUROLINE-WB, and Western blot formats.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStandardized Processing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomated incubation, washing, and reagent dispensing improve precision and reproducibility.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMulti-Conjugate Capability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports different conjugates and test combinations within a single run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDual Throughput Options\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAvailable in two models for processing up to 30 or up to 44 strips per run.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStandalone Operation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated display and membrane keyboard remove the need for an external PC.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUser-Friendly Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSimple menu navigation and six-key operation support convenient daily use.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLow Maintenance\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eDaily maintenance takes no more than five minutes for efficient workflow support.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCompact Footprint\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBenchtop design saves laboratory space while maintaining reliable performance.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Disease Diagnostics:\u003c\/strong\u003e Processing of immunoblot assays for autoantibody detection.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Western blot and line blot assays for pathogen-specific antibody profiling.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Testing:\u003c\/strong\u003e Multiparameter immunoblot analysis for allergen-specific antibodies.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Laboratory Automation:\u003c\/strong\u003e Standardized routine testing with reduced manual intervention.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Laboratories:\u003c\/strong\u003e Reliable and reproducible blot processing for immunological studies.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375932797109,"sku":"EU-LAB-BLM","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROBlotMaster_Compact_Immunoblot_Strip_Processor.jpg?v=1774247227"},{"product_id":"eurolinescan-automated-evaluation-of-membrane-based-test-systems","title":"EUROLineScan Automated Evaluation of Membrane-Based Test Systems","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eEUROLineScan software enables fully automated, quantitative evaluation of EUROIMMUN blot strips, along with data management and electronic archiving. It also simplifies incubation workflows by generating clearly structured work protocols, including integration with LIS or EUROLabOffice 4.0.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eIncubated strips are scanned via flatbed scanner or captured directly using an integrated camera system. The software automatically detects strip positions, identifies bands, and measures signal intensity.\u003c\/p\u003e\n            \u003cp\u003eUsers can review results through overview and detailed views for validation. All results and image data are automatically stored, eliminating the need to retain potentially infectious physical blot strips.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated evaluation for all EUROIMMUN blot strips including EUROLINE, EUROLINE-WB, and Western blot\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eElectronic archiving of images and data without storing physical strips\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eSecure data communication via LIS or EUROLabOffice connection\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCustomizable selection windows and print layouts\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eData security through personalized user management\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAdditional quality control using EUROLINE validation strips\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Blot Evaluation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eQuantitative analysis of EUROIMMUN blot strips with minimal manual intervention.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntelligent Image Recognition\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic strip detection, band identification, and precise intensity measurement.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDigital Archiving System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSecure storage of images and results eliminates the need for physical strip archiving.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Data Acquisition\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompatible with flatbed scanners or integrated camera systems for workflow flexibility.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Integration Ready\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports secure, bidirectional communication with LIS and EUROLabOffice 4.0.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCustomizable Reporting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eFlexible configuration of selection windows and print layouts for tailored reporting.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eEnhanced Data Security\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003ePersonalized user management ensures controlled access and traceability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eBuilt-in Quality Control\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports EUROLINE validation strips for additional assay reliability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAutoimmune Diagnostics:\u003c\/strong\u003e Automated interpretation of immunoblot strips for autoantibody profiling.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Standardized blot analysis for pathogen detection.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eAllergy Testing:\u003c\/strong\u003e Quantitative evaluation of allergen-specific immunoblot strips.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Data Management:\u003c\/strong\u003e Digital workflows for result validation, storage, and reporting.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Applications:\u003c\/strong\u003e High-throughput, reproducible blot analysis for immunological studies.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375946002613,"sku":"EU-LAB-LNS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROLineScan_Automated_Evaluation_of_Membrane-Based_Test_Systems.jpg?v=1774247978"},{"product_id":"euroarrayscanner-fully-automated-evaluation-for-standardized-fast-and-reliable-analyses-of-euroimmun-microarrays","title":"EUROArrayScanner Fully Automated Evaluation for Standardized, Fast and Reliable Analyses of EUROIMMUN Microarrays","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eEUROArrays after hybridization are analyzed using the EUROArrayScanner. The EUROArrayScan software automatically detects array positions and quantifies DNA probe signal intensities with high precision.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eWithin seconds, signal intensities are measured for all samples, while integrated controls are automatically included in the evaluation process. Manual interpretation is not required.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe software generates structured work protocols for each run, ensuring simple and secure sample processing.\u003c\/p\u003e\n            \u003cp\u003eResults can be displayed as an overview or detailed individual reports, including associated array images for verification. Users can add comments, and all results are automatically archived with image data, eliminating the need to retain physical microarrays.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAnalysis and evaluation system for molecular diagnostic products\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated evaluation, analysis, and data archiving\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eRapid fluorescence scanning with one slide processed in under 20 seconds\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eResult output as overview or detailed individual analysis\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAbility to add comments to results\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eLIS connectivity and network integration for efficient data communication\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFully Automated Microarray Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic detection of array positions and precise quantification of DNA probe signals.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eHigh-Speed Fluorescence Scanning\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProcesses one slide in under 20 seconds for rapid data acquisition.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Data Processing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSimultaneous analysis, evaluation, and documentation without manual interpretation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDigital Archiving\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomatic storage of results with array images removes the need for physical slide retention.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Quality Control\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIntegrated controls are automatically applied to ensure reliable and accurate results.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Reporting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eGenerate overview reports or detailed individual analyses with full transparency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCustom Annotation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAdd user-defined comments directly to result reports for enhanced interpretation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSeamless connectivity with LIS and network systems for efficient data communication.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eMolecular Diagnostics:\u003c\/strong\u003e Automated analysis of DNA microarrays for genetic and molecular profiling.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Detection:\u003c\/strong\u003e Identification of pathogen-specific genetic markers using array-based assays.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eGenotyping \u0026amp; Mutation Analysis:\u003c\/strong\u003e High-throughput evaluation of DNA probes for genetic variation studies.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Laboratory Automation:\u003c\/strong\u003e Standardized workflows for microarray-based testing with minimal manual handling.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Applications:\u003c\/strong\u003e Fast, reproducible data acquisition for genomics and molecular biology research.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52375952261301,"sku":"EU-LAB-ARS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROArrayScanner_Fully_Automated_Evaluation_for_Standardized_Fast_and_Reliable_Analyses_of_EUROIMMUN_Microarrays.jpg?v=1774248375"},{"product_id":"euroarrayprocessor-fully-automated-processing-of-euroarray-slides","title":"EUROArrayProcessor Fully Automated Processing of EUROArray Slides","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe EUROArrayProcessor automates post-PCR processing, including dilution with hybridization buffer, transfer to reagent trays, hybridization of PCR reactions, washing, and drying of EUROArray slides.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eAutomated processing of up to 192 PCR preparations and 40 EUROArray slides per run using TITERPLANE technology\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eStandardized and reproducible washing with automated drying for optimal results\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eEnhanced safety and traceability via barcode identification of slides, reagent trays, and reagents\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eOptimized Workflow Automation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eFully automated pipetting, hybridization, washing, and drying on a single system with no manual intermediate steps.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003eEnd-to-end processing from PCR sample to ready-to-evaluate EUROArray slide\u003c\/li\u003e\n\u003cli\u003eUse of buffer concentrates simplifies run preparation\u003c\/li\u003e\n\u003cli\u003eMinimal hands-on time (~15 minutes for up to 40 slides \/ 192 samples)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_899cc152-1bf7-4b0f-98dc-8addd5ce7ea4.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eEconomic \u0026amp; Precise Pipetting\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eHigh-precision liquid handling ensures accuracy and minimizes contamination risk.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003eCoated stainless-steel needle with precision pump\u003c\/li\u003e\n\u003cli\u003eEffective needle washing to prevent carry-over\u003c\/li\u003e\n\u003cli\u003eCapacitive liquid level detection for safe pipetting\u003c\/li\u003e\n\u003cli\u003eReduced cross-contamination via direct piercing of PCR plate film\u003c\/li\u003e\n\u003cli\u003eNo evaporation during hybridization using TITERPLANE technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/2_44b45846-2f01-4661-9c94-4ae8afa91556.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReliable Results\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eAdvanced washing and drying ensure high-quality, reproducible outcomes.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003eIntegrated washing unit for automated slide cleaning\u003c\/li\u003e\n\u003cli\u003eStandardized washing with precise control\u003c\/li\u003e\n\u003cli\u003ePinpoint washing without carry-over\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled washing with active cooling\u003c\/li\u003e\n\u003cli\u003eAutomated drying for optimal signal quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/2_ebf9ac58-030f-4d98-a56a-262931eefc37.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eConvenient Operation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eUser-friendly system design for streamlined laboratory workflows.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003ePC-based touchscreen interface\u003c\/li\u003e\n\u003cli\u003eEasy worklist execution\u003c\/li\u003e\n\u003cli\u003eProtocol generation with or without LIS\u003c\/li\u003e\n\u003cli\u003eLot traceability for PCR reagents\u003c\/li\u003e\n\u003cli\u003eOptional volume calculation and pipetting layout display\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/3_36c28673-238c-4b91-9059-768f90da20a2.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible EUROArray Combination\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports multiple assay types and optimized test combinations.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003eProcessing of up to six different EUROArray tests per run\u003c\/li\u003e\n\u003cli\u003eOptimized protocols for multi-test workflows\u003c\/li\u003e\n\u003cli\u003eSupports slides with three or five reaction fields\u003c\/li\u003e\n\u003cli\u003eDataMatrix code reader for slide identification\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled hybridization per assay type\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/4_fdd5637f-3da9-4938-84f2-14bbb8420d8a.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eEnd-to-End Process Safety\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eComprehensive system controls ensure secure and error-free operation.\u003c\/p\u003e\n\u003cul style=\"padding-left: 18px; margin-top: 10px; color: #666;\"\u003e\n\u003cli\u003eUser-based access control and permissions\u003c\/li\u003e\n\u003cli\u003eReal-time system overview and resource monitoring\u003c\/li\u003e\n\u003cli\u003eAutomated sensor-based loading checks before runs\u003c\/li\u003e\n\u003cli\u003eSecure data exchange with Pre-NAT II and EUROArrayScan software\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cimg style=\"width: 100%; margin-top: 10px; border-radius: 6px;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/5_3e290378-dfac-4a0a-858d-525118650c02.jpg?v=1774249212\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"column-count: 1; gap: 30px;\"\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eMolecular Diagnostics Workflows:\u003c\/strong\u003e Automated post-PCR processing for DNA microarray-based assays, ensuring standardized hybridization and slide preparation.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e High-throughput processing of PCR products for pathogen detection using array-based platforms.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eGenetic Analysis \u0026amp; Genotyping:\u003c\/strong\u003e Reliable preparation of EUROArray slides for mutation screening and genetic profiling.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical Laboratory Automation:\u003c\/strong\u003e Streamlined laboratory workflows with reduced manual handling and improved reproducibility.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Research:\u003c\/strong\u003e Efficient processing of large sample volumes for genomics and molecular biology studies.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52376031133877,"sku":"EU-LAB-ARP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_ef779d0e-85b0-42ea-a3cc-8346f0d23ff4.jpg?v=1774249340"},{"product_id":"eurorealtime-analysis-automated-evaluation-and-documentation","title":"EURORealTime Analysis Automated Evaluation and Documentation","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eEURORealTime Analysis software enables simplified processing and fully automated evaluation of EURORealTime PCR test systems. It supports sample entry and assignment to specific tests while automatically generating pipetting schemes and MasterMix preparations based on input data.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eIntegrated import and export modules allow standardized evaluation of raw data from selected PCR cyclers. Internal and external controls are automatically included, eliminating the need for manual cut-off definition.\u003c\/p\u003e\n            \u003cp\u003eAt the end of each run, the software provides clear result summaries with optional amplification curves. It also supports LIS connectivity for seamless data exchange and workflow integration.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated evaluation and workflow support for real-time PCR analyses\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eStandardized and automated raw data analysis\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eFully automated report generation including all internal and external controls\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eGuided workflow for efficient and convenient operation\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated PCR plate layout creation with required controls\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eReusable standard curves for cost-effective quantification\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eStructured output of individual data with optional amplification curves\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCompatible with various PCR platforms and LIS systems\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated PCR Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eFully automated evaluation of real-time PCR test systems with minimal manual input.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntelligent Workflow Guidance\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports sample entry, test allocation, and step-by-step workflow management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated Pipetting Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eGenerates pipetting schemes and MasterMix preparation to reduce errors and setup time.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eStandardized Data Processing\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomated import\/export ensures consistent analysis across supported PCR cyclers.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Control Management\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomatically incorporates internal and external controls without manual thresholds.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eComprehensive Reporting\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eGenerates structured reports with individual data and optional amplification curves.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePCR Plate Layout Automation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomatically creates optimized plate layouts including all required controls.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Quantification\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSupports reusable standard curves for cost-efficient quantitative analysis.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eLIS Connectivity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666;\"\u003eSeamless integration with LIS systems for efficient data exchange and workflow automation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Molecular Diagnostics:\u003c\/strong\u003e Automated real-time PCR data analysis for pathogen detection and disease diagnostics.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eqPCR Quantification:\u003c\/strong\u003e Accurate nucleic acid quantification using standardized workflows and reusable curves.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Workflow Automation:\u003c\/strong\u003e Simplifies PCR setup, data processing, and reporting in routine laboratories.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eInfectious Disease Testing:\u003c\/strong\u003e Reliable evaluation of amplification data for viral and bacterial targets.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResearch Applications:\u003c\/strong\u003e Efficient processing and interpretation of qPCR experiments in genomics and molecular biology.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377846644917,"sku":"EU-LAB-ERT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EURORealTime_Analysis_Automated_Evaluation_and_Documentation.jpg?v=1774319171"},{"product_id":"auto-pure-20b-automated-cell-isolation-system-with-flexible-throughput","title":"Auto-Pure 20B Automated Cell Isolation System With Flexible Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\u003c!-- Description --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe Auto-Pure 20B automated magnetic bead cell isolation system is designed for efficient PBMC isolation, supporting the Revvity T-SPOT™.TB test and T-Cell Select™ reagent kit. A dedicated protocol enables rapid and automated processing of peripheral blood mononuclear cells.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003eThe system utilizes magnetic rod technology to perform mixing, binding, washing, and elution steps, ensuring consistent purification performance.\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eBuilt-in flexibility:\u003c\/strong\u003e Strip-based operation allows variable batch sizes, optimizing consumable usage and improving workflow efficiency.\u003c\/p\u003e\n\u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eEasy operation with minimal maintenance requirements\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e7-inch full-color touchscreen interface with shortcut keys\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eWalk-away operation: up to 20 samples processed in under 45 minutes\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eDrawer-based design for convenient loading\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003ePre-loaded T-Cell Select reagent protocol\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eIntegrated lighting and exhaust system\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003eUV sterilization function for contamination control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Specifications --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProcessing Volume\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e3.5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Quantity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1–20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProtocol Storage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePre-loaded T-Cell Select reagent protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eExternal Interfaces\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eUSB, Ethernet port, Wi-Fi, built-in SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Conditions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eEnvironmental temperature: 10–35 °C\u003cbr\u003eRelative humidity: ≤ 70 %\u003cbr\u003eInput voltage: AC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e450 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e400 × 520 × 450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f6fa;\"\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Key Features --\u003e\n\u003csection style=\"margin-bottom: 40px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eAutomated PBMC Isolation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eMagnetic bead-based system enables efficient and reproducible PBMC purification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eMagnetic Rod Technology\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eAutomates mixing, binding, washing, and elution for consistent results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eHigh Throughput Efficiency\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eProcesses up to 20 samples in under 45 minutes with minimal hands-on time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eFlexible Operation\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eStrip-based workflow supports variable batch sizes and optimized reagent usage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003ePreloaded Protocols\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eIncludes dedicated T-cell isolation protocol for standardized workflows.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eUser-Friendly Interface\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003e7-inch touchscreen with intuitive controls for easy operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eEnhanced Safety\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eUV sterilization, internal lighting, and exhaust system support contamination control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n\u003ch3 style=\"color: #004a99; font-size: 18px;\"\u003eCompact Design\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; color: #666;\"\u003eSpace-saving benchtop system with convenient drawer-based loading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c!-- Applications --\u003e\n\u003csection style=\"margin-bottom: 20px;\"\u003e\n\u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eTB Immunology Testing:\u003c\/strong\u003e PBMC isolation for T-cell based tuberculosis assays such as ELISPOT workflows.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCell Isolation \u0026amp; Preparation:\u003c\/strong\u003e Enrichment of mononuclear cells for downstream immunological analysis.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eClinical Laboratory Automation:\u003c\/strong\u003e Standardized sample preparation for diagnostic workflows.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eImmunology Research:\u003c\/strong\u003e PBMC preparation for cytokine studies and immune monitoring.\u003c\/div\u003e\n\u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHigh-Throughput Processing:\u003c\/strong\u003e Rapid handling of multiple samples for routine and research applications.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377865748661,"sku":"Auto-Pure 20B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Auto-Pure_20B_Automated_Cell_Isolation_System_With_Flexible_Throughput.jpg?v=1774319588"},{"product_id":"auto-pure-24-automated-cell-isolation-system-for-mid-high-throughput","title":"Auto-Pure 24 Automated Cell Isolation System for Mid-High Throughput","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe Auto-Pure 24 magnetic separation system is an ideal partner for the Revvity T-SPOT™.TB test and T-Cell Select™ reagent kit in medium high-throughput laboratories.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003e\u003cstrong\u003eDesigned for automation\u003c\/strong\u003e\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eIts plate-based design allows convenient processing of up to 24 samples per run using the pre-loaded T-Cell Select reagent protocol. The plates are compatible with liquid handling platforms, enabling greater walk-away time and improved workflow automation.\u003c\/p\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eA custom protocol supports rapid and efficient automation of the peripheral blood mononuclear cell (PBMC) isolation stage of the T-SPOT.TB test. The Auto-Pure 24 uses a tip-comb and 24-well deep-well plates to process samples. The magnet captures the cell-antibody-bead complex, which is then washed and eluted.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eEasy to use with minimal maintenance\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eAutomated pre-analysis plate checking with drip protection technology\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e7 inch full color touch screen interface\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eWalk away operation: 24 samples isolated in \u0026lt; 45 minutes\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eRotary table design with large access door for easy loading\/unloading\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003ePre-loaded custom T-Cell Select reagent protocol with optimized mixing and agitation for efficient cell extraction\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eInternal lighting and exhaust fan\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eUV sterilization function\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eProcessing Volume\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e3.5 mL*\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eSample Quantity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e1–24\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eProtocol Storage\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003ePre-loaded T-Cell Select reagent protocol\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eExternal Interfaces\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e4 standard USB, Ethernet port, Wi-Fi, built-in SD card\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Conditions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eEnvironmental temperature: 10–35 °C\u003cbr\u003eRelative humidity: ≤ 70 %\u003cbr\u003eInput voltage: AC 100–240 V, 50\/60 Hz\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e300 W\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDimensions (W × D × H)\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e560 × 620 × 500 mm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e54 kg\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAutomated PBMC Isolation Workflow\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eMagnetic separation system enables efficient isolation of peripheral blood mononuclear cells with minimal manual handling.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePlate-Based High-Throughput Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProcesses up to 24 samples per run using deep-well plates for improved laboratory efficiency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eTip-Comb Magnetic Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnsures precise capture, washing, and elution of cell–antibody–bead complexes for consistent results.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePreloaded Optimized Protocols\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIncludes dedicated reagent protocols with optimized mixing and agitation for reliable cell extraction.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eWalk-Away Automation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompletes up to 24 sample isolations in less than 45 minutes, reducing hands-on time.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntelligent Pre-Run Safety Checks\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAutomated plate checking and drip protection technology improve operational reliability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUser-Friendly Touchscreen Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003e7-inch full-color display simplifies workflow control and monitoring.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eRotary Table System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eLarge access door and rotating platform enable easy loading and unloading of samples.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eEnhanced Contamination Control\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eBuilt-in UV sterilization, internal lighting, and exhaust fan support a clean working environment.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Connectivity Options\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports USB, Ethernet, Wi-Fi, and SD card for data handling and integration.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eTB Immunodiagnostics:\u003c\/strong\u003e Automated PBMC isolation for T-cell–based tuberculosis testing workflows.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Sample Preparation:\u003c\/strong\u003e Standardized preparation of blood-derived cells for diagnostic assays.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eImmunology Research:\u003c\/strong\u003e Isolation of mononuclear cells for downstream immune function and cellular analysis studies.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Automation:\u003c\/strong\u003e Integration into automated platforms for medium to high-throughput sample processing.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eCell-Based Assays:\u003c\/strong\u003e Preparation of high-quality cell populations for ELISPOT and other immunological assays.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377875120309,"sku":"Auto-Pure 24","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/Auto-Pure_24_Automated_Cell_Isolation_System_for_Mid-High_Throughput.jpg?v=1774319950"},{"product_id":"procisedx-analyzer-trfret-technology-for-therapeutic-drug-monitoring-tdm","title":"ProciseDx Analyzer TrFRET Technology for Therapeutic Drug Monitoring (TDM)","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe \u003cstrong\u003eProciseDx Analyzer\u003c\/strong\u003e is a compact, easy-to-use instrument for quantitation of drug levels in venous serum samples. It features a touchscreen interface and external barcode scanning for sample identification and tracking.\u003c\/p\u003e\n            \u003cp\u003eUsing unique time-resolved fluorescence resonance energy transfer (trFRET) and patented Lumiphore technology, the system delivers high-quality results in less than 5 minutes.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Specifications --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eSpecifications\u003c\/h2\u003e\n        \u003cdiv style=\"overflow-x: auto;\"\u003e\n            \u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 600px; border: 1px solid #ddd;\"\u003e\n                \u003cthead\u003e\n                    \u003ctr style=\"background-color: #004a99; color: #ffffff;\"\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n                        \u003cth style=\"padding: 12px 15px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                \u003c\/thead\u003e\n                \u003ctbody\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold; width: 30%;\"\u003eDimensions\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e15 inch (D) × 8 inch (W) × 5.7 inch (H)\u003cbr\u003e(38.4 cm × 21 cm × 14.5 cm)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e10 lbs (4.7 kg)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Supply Input\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100–240 VAC, 50\/60 Hz, auto-ranging (US \/ International)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e90 VA\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eDisplay\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e6 inch × 3.5 inch (15 cm × 9 cm) color LCD touchscreen\u003cbr\u003e7 inch (17.5 cm) diagonal\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Temperature\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e59°F to 86°F (15°C to 30°C)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eOperating Humidity\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e20% – 85% RH (non-condensing)\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003ePatient Test Result Storage\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e250 tests maximum\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eQC Results Storage\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e500 results maximum\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eCalibration Results Storage\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e100 results maximum\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eFluorescence\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e0 to 65 × 10\u003csup\u003e6\u003c\/sup\u003e RFU ±5% at 620 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eAbsorbance\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003e0 to \u0026gt;3.5 OD ±0.3 OD at 575 nm and 665 nm\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #ffffff;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eWi-Fi\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eIEEE 802.11 ac\/a\/b\/g\/n\u003cbr\u003e2.4 GHz \/ 5 GHz\u003cbr\u003eWEP \/ WPA \/ WPA2\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                    \u003ctr style=\"background-color: #f2f6fa;\"\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd; font-weight: bold;\"\u003eEthernet\u003c\/td\u003e\n                        \u003ctd style=\"padding: 10px 15px; border: 1px solid #ddd;\"\u003eRJ45 Connector (1)\u003cbr\u003e10\/100\/1000 BASE-T\u003c\/td\u003e\n                    \u003c\/tr\u003e\n                \u003c\/tbody\u003e\n            \u003c\/table\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eRapid Quantitative Analysis\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eDelivers accurate drug level measurements from serum samples in under 5 minutes.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced trFRET Technology\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eUses time-resolved fluorescence resonance energy transfer for high sensitivity and precision.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eProprietary Detection System\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eIncorporates patented Lumiphore technology for reliable and high-quality signal performance.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCompact Benchtop Design\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSpace-saving instrument suitable for clinical laboratories and point-of-care settings.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntuitive Touchscreen Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003e7-inch color LCD touchscreen supports simple operation and efficient workflow management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eBarcode-Based Sample Tracking\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eExternal barcode scanning ensures accurate sample identification and traceability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Data Storage\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eStores patient results, QC data, and calibration records for efficient data management.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Connectivity\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports Wi-Fi and Ethernet for seamless data transfer and network integration.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eBroad Detection Range\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports both fluorescence and absorbance measurements for diverse assay requirements.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eTherapeutic Drug Monitoring (TDM):\u003c\/strong\u003e Quantitative measurement of drug concentrations in serum for treatment optimization.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Diagnostics:\u003c\/strong\u003e Rapid assessment of drug levels to support clinical decision-making.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003ePoint-of-Care Testing:\u003c\/strong\u003e Fast turnaround analysis suitable for near-patient testing environments.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003ePharmacokinetic Studies:\u003c\/strong\u003e Monitoring drug absorption and metabolism in clinical research.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Workflow Optimization:\u003c\/strong\u003e Efficient and automated testing for routine clinical laboratories.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377879543989,"sku":"PDC-ANA-PDX","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/ProciseDx_Analyzer_TrFRET_Technology_for_Therapeutic_Drug_Monitoring_TDM.jpg?v=1774320686"},{"product_id":"eurolaboffice-4-0-flexible-laboratory-management-software","title":"EUROLabOffice 4.0 Flexible Laboratory Management Software","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp style=\"margin-bottom: 15px;\"\u003eThe laboratory management system EUROLabOffice simplifies and speeds up the daily routine in the diagnostic laboratory and increases security through organization of the entire laboratory procedure and traceable documentation of all data and processes. EUROLabOffice offers many advantages for both the smaller laboratory with mainly manual workstations as well as for high-throughput laboratories with many connected automated systems and workstations.\u003c\/p\u003e\n            \u003cul style=\"margin-top: 15px; padding-left: 20px; list-style-type: square; color: #555;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eEfficient consolidation in serology through support of all EUROIMMUN products for autoimmune, infection, allergy and molecular genetic diagnostics and antigen detection\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eCentral interface between all EUROIMMUN instruments and the LIS for maximal automation and minimal manual working steps\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eIncrease in the efficiency and reproducibility of all working steps: Completely paperless work procedures in accordance with automated protocols – from easy management of test requests, (cost-) optimized performance of analyses, IFA result entry in the PC, archiving of IFA and blot images, right up to the end result\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003eSecurity and comprehensive data processing via automated and complete data communication between the LIS and all workstations\u003c\/li\u003e\n                \u003cli\u003eFlexible and open system for adaptation to existing laboratory processes with various expansion modules, e.g. for optimized sample sorting, inventory management, reflex testing or quality control, or for a consolidated, serological validation including result dispatch (also with web application for laboratories and doctors submitting samples)\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eComprehensive Laboratory Management\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCentralized system for organizing, monitoring, and documenting all laboratory workflows and processes.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eSeamless Instrument Integration\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eActs as a central interface connecting diagnostic instruments with the LIS for fully automated data exchange.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003ePaperless Workflow Automation\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnables complete digital handling of test requests, processing, and result reporting to improve efficiency.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eEnhanced Data Traceability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnsures full documentation and traceability of samples, processes, and results across the laboratory.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eMulti-Discipline Support\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCompatible with serology, molecular testing, antigen detection, and other diagnostic applications.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eOptimized Workflow Efficiency\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eReduces manual steps while improving reproducibility through standardized automated protocols.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eFlexible Modular Architecture\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eAdaptable system with expansion modules for sample sorting, inventory management, reflex testing, and quality control.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Data Communication\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProvides secure and automated communication between all workstations and laboratory systems.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Result Management\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSupports image archiving, digital result entry, and automated reporting for streamlined laboratory operations.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Laboratory Management:\u003c\/strong\u003e Central coordination of diagnostic workflows in routine and high-throughput laboratories.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eSerological Testing Workflows:\u003c\/strong\u003e Management of autoimmune, infection, and allergy testing processes with unified data handling.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Automation Integration:\u003c\/strong\u003e Integration and control of multiple instruments and workstations within a single system.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eData \u0026amp; Process Traceability:\u003c\/strong\u003e Secure tracking and documentation of samples, results, and laboratory activities.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eQuality Control \u0026amp; Compliance:\u003c\/strong\u003e Implementation of standardized procedures and quality monitoring across laboratory operations.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377894650037,"sku":"EU-SOFT-ELO","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROLabOffice_4.0_Flexible_Laboratory_Management_Software.jpg?v=1774321937"},{"product_id":"europicture-acquisition-visualisation-and-administration-of-ift-images","title":"EUROPicture Acquisition, Visualisation and Administration of IFT Images","description":"\u003cdiv style=\"font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; color: #333; line-height: 1.6; max-width: 1200px; margin: 0 auto; padding: 10px;\"\u003e\n\n    \u003c!-- Description --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eDescription\u003c\/h2\u003e\n        \u003cdiv style=\"background-color: #f9f9f9; padding: 20px; border-radius: 4px; border: 1px solid #eee;\"\u003e\n            \u003cp\u003eThe program EUROPicture is designed for image acquisition, visualization and administration of fluorescence images in in vitro diagnostics. EUROPicture enables images to be saved for archiving, result reports and later viewing.\u003c\/p\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Key Features --\u003e\n    \u003csection style=\"margin-bottom: 40px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 25px;\"\u003eKey Features\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 25px;\"\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eIntegrated Image Acquisition\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eCaptures fluorescence images directly for immediate visualization and analysis.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eAdvanced Image Visualization\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eProvides clear display of fluorescence images to support accurate interpretation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eCentralized Image Management\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eOrganizes and manages image data efficiently within a single software environment.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eDigital Archiving Capability\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eStores images securely for long-term access, documentation, and traceability.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eReporting Support\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eEnables inclusion of images in diagnostic reports for comprehensive result presentation.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n            \u003cdiv style=\"border: 1px solid #eee; padding: 15px; border-radius: 8px; background: #fff; box-shadow: 0 2px 5px rgba(0,0,0,0.05);\"\u003e\n                \u003ch3 style=\"color: #004a99; font-size: 18px; margin-top: 0;\"\u003eUser-Friendly Interface\u003c\/h3\u003e\n                \u003cp style=\"font-size: 14px; color: #666; margin-bottom: 0;\"\u003eSimple and intuitive design for efficient workflow integration in laboratory settings.\u003c\/p\u003e\n            \u003c\/div\u003e\n\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n    \u003c!-- Applications --\u003e\n    \u003csection style=\"margin-bottom: 20px;\"\u003e\n        \u003ch2 style=\" padding-left: 15px; color: #004a99; font-size: 24px; text-transform: uppercase; margin-bottom: 20px;\"\u003eApplications\u003c\/h2\u003e\n        \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(280px, 1fr)); gap: 15px;\"\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eImmunofluorescence Testing (IFT):\u003c\/strong\u003e Acquisition and visualization of fluorescence images for diagnostic evaluation.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eClinical Diagnostics:\u003c\/strong\u003e Image documentation and reporting for routine laboratory testing.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eLaboratory Data Management:\u003c\/strong\u003e Storage and organization of imaging data for traceability and review.\n            \u003c\/div\u003e\n            \u003cdiv style=\"padding: 10px; border-bottom: 1px solid #eee;\"\u003e\n                \u003cstrong\u003eResult Verification:\u003c\/strong\u003e Visual confirmation of fluorescence patterns to support diagnostic decisions.\n            \u003c\/div\u003e\n        \u003c\/div\u003e\n    \u003c\/section\u003e\n\n\u003c\/div\u003e","brand":"euroimmun","offers":[{"title":"Default Title","offer_id":52377899958453,"sku":"EU-SOFT-EUP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/EUROPicture_Acquisition_Visualisation_and_Administration_of_IFT_Images.jpg?v=1774322436"},{"product_id":"led-light-box","title":"LED Light Box","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eWith powerful long-lasting, dual LEDs, the Carolina® LED light box emits either white or blue light, giving you increased options during gel staining and viewing. Designed with the classroom in mind, this light box is made with a durable molded polymer casing and features a small footprint for easy storage and saving space.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIn the white light mode, the box emits safe light ideal for visualizing gels stained with CarolinaBLU®.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsing the blue light setting with the included filter provides a safer alternative to UV light for observing gels stained with GelGreen®.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBlue LED is 470 nm; white LED is 9000 K. Blue filter in use is 450 nm; amber filter in use is 580 nm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen using the LED light box for digital imaging with cameras or smartphones, consider adding a Carolina® Light Box Photo Hood (item #213701).\u003c\/p\u003e\n\u003ch2\u003eNote\u003c\/h2\u003e\n\u003cp\u003eFor international customers, this product can accept 220-V AC if you use a plug adapter (not included).\u003c\/p\u003e","brand":"Carolina","offers":[{"title":"Default Title","offer_id":52382797136053,"sku":"213694","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/LED_Light_Box.jpg?v=1774401123"},{"product_id":"hesper-ii-chemiluminescence-imaging-system","title":"Hesper II Chemiluminescence Imaging System","description":"\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eThe Hesper II Chemiluminescence Imaging System is Mona’s next-generation fully integrated motorized sample-loading imaging platform, featuring a modern all-in-one design with a large touchscreen interface for intuitive operation and enhanced laboratory workflow efficiency.\u003c\/p\u003e\n\u003cp\u003eThis advanced imaging system integrates a high-performance camera assembly composed of a 15-megapixel ultra-sensitive deep-space astronomy-grade sCMOS camera, a four-stage thermoelectric cooling system, and an F0.95 ultra-large aperture lens. These core components work in precise coordination to deliver exceptional image acquisition performance under ultra-low-light conditions.\u003c\/p\u003e\n\u003cp\u003eEquipped with intelligent imaging software, the Hesper II system supports Bin8 pixel binning mode, enabling an optimized balance between ultra-high sensitivity and high-resolution imaging. The system also combines automatic and manual exposure modes, as well as single-frame and multi-frame exposure acquisition, providing flexible imaging solutions for protein bands with varying abundance levels.\u003c\/p\u003e\n\u003cp\u003eWith its streamlined one-click imaging workflow, the Hesper II Chemiluminescence Imaging System delivers a professional and efficient solution for Western blot and chemiluminescent detection applications.\u003c\/p\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eHesper II Chemiluminescence Imaging System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eSKU\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eGD50402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eImaging Area\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e17 × 19 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eScientific sCMOS Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eSensor Size\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e4\/3 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e15 Megapixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003ePixel Size\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e3.8 × 3.8 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eGray Scale\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e16-bit, 0–65535 Gray Levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003ePixel Binning Modes\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eHigh-Resolution Mode (2 × 2), Standard Mode (4 × 4), Ultra-Sensitive Mode (8 × 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eCooling Temperature\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e-30°C @ 25°C Ambient Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eQuantum Efficiency (QE)\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eLens\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e25 mm F0.95 Lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eDisplay Size\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e13.3 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eRead Noise\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1.0 e-RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1920 × 1080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eExternal Dimensions\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e33.1 (W) × 45.0 (D) × 37 (H) cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eAC 80–264 V, 47–63 Hz, 200 VA Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e24.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003eDeep-Space Astronomy-Grade Cooled sCMOS Camera\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScientific-Grade sCMOS Sensor\u003cbr\u003e\u003c\/strong\u003eCompared with conventional industrial CMOS sensors, the scientific-grade sCMOS sensor provides significantly higher sensitivity and superior signal-to-noise performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-High Sensitivity\u003cbr\u003e\u003c\/strong\u003eCompared with CCD-based systems, the Hesper II offers higher photoelectric conversion efficiency with reduced signal loss, enabling more reliable detection of weak chemiluminescent signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Resolution\u003cbr\u003e\u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eEquipped with a 15-megapixel imaging sensor, delivering sharper, clearer, and more detailed images.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eAdvanced Cooling and Heat Dissipation System\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFour-Stage Thermoelectric Cooling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnables rapid temperature reduction and maintains stable low-temperature camera operation even under high ambient temperature conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Water-Cooling and Air-Cooling System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombines water cooling and forced-air cooling to minimize background noise and improve imaging stability during long exposure acquisition.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eUser-Oriented Structural Design\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion-Resistant Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe instrument housing and dark chamber are specially treated for corrosion resistance, improving durability and extending instrument service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated All-in-One Platform\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe compact integrated design enhances laboratory space utilization while providing a clean and professional appearance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eIntelligent Imaging Software with One-Click Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Exposure Modes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports both single-exposure and multi-exposure imaging modes with automatic or manual exposure settings, making the system suitable for protein bands with different expression levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOne-Click Imaging\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenerates chemiluminescence images, marker images, and overlay images with a single click, simplifying operation and improving visualization efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOne-Click Batch Saving\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports one-click saving of multiple images with selectable output formats.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRaw File Management\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports automatic saving of raw image files and re-importing for subsequent image review and analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eComprehensive Software Functions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUser Management and Audit Trail\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures hierarchical user management and categorized operation log tracking, facilitating experimental traceability and laboratory management compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eImage Processing Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports rapid image acquisition, image rotation, and other image editing functions for efficient and convenient workflow operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComponents\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eHesper II Chemiluminescence Imaging System\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003ePower Cord\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eMouse\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eKeyboard\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eUSB Drive\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eWireless Network Adapter\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eHesper II Chemiluminescence Sample Tray\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eImaging Calibration Plate (9 × 9 cm)\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eFuse (3 A)\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e2 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eQuick Operation Guide\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003ePacking List\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eFactory Inspection Report\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003eCertificate of Conformity\u003c\/td\u003e\n\u003ctd style=\"width: 48.7815%; text-align: center;\"\u003e1 copy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"monadbiotech","offers":[{"title":"1Set","offer_id":52492646908085,"sku":"GD50202","price":21343.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/files\/1_9dad43b6-d2fd-48af-b376-512e14fe0a27.jpg?v=1778054997"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0521\/5312\/2997\/collections\/00001_63f7f97c-6a3c-47cd-bd34-90566767b725.jpg?v=1775718306","url":"https:\/\/biofargo.com\/collections\/imaging-detection.oembed","provider":"Biofargo","version":"1.0","type":"link"}